HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (14 Jun 2025)

PDF GB/T 14849.5-2014 English (GB/T 14849.5-2010: Older version)


Search result: GB/T 14849.5-2014 (GB/T 14849.5-2010 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 14849.5-2014English170 Add to Cart 0-9 seconds. Auto-delivery. Chemical analysis of silicon metal - Part 5: Determination of impurity elements content - Analysis using an X-ray fluorescence method Valid
GB/T 14849.5-2010English239 Add to Cart 2 days Chemical analysis of silicon metal -- Part 5: Determination of elements content -- Analysis using an X-ray fluorescence method Obsolete

PDF Preview: GB/T 14849.5-2014                   
      

GB/T 14849.5-2014: PDF in English (GBT 14849.5-2014)

GB/T 14849.5-2014 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 77.120.10 H 12 Replacing GB/T 14849.5-2010 Methods for chemical analysis of silicon metal - Part 5: Determination of impurity contents - X-ray fluorescence method ISSUED ON: DECEMBER 05, 2014 IMPLEMENTED ON: MAY 01, 2015 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of PRC; Standardization Administration of PRC. Table of Contents Foreword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Method summary ... 5 4 Instruments and materials ... 6 5 Specimens ... 6 6 Steps ... 7 7 Precision ... 8 8 Quality assurance and control ... 9 9 Test report ... 10 Appendix A (Informative) Measurement condition parameters of two kinds of X-ray fluorescence spectrometers ... 11 Appendix B (Informative) Possible elemental interference spectral lines ... 12 Methods for chemical analysis of silicon metal - Part 5: Determination of impurity contents - X-ray fluorescence method 1 Scope This Part of GB/T 14849 stipulates the determination method of iron, aluminum, calcium, manganese, nickel, titanium, copper, phosphorus, magnesium, chromium, vanadium, cobalt content in industrial silicon. This Part is applicable to the determination of iron, aluminum, calcium, manganese, nickel, titanium, copper, phosphorus, magnesium, chromium, vanadium, cobalt in industrial silicon. The determination range is as shown in Table 1. 2 Normative references The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this standard. GB/T 8170 Rules of rounding off for numerical values & expression and judgement of limiting values 3 Method summary X-ray fluorescence spectrometry is a qualitative and quantitative analysis, by measuring the wavelength and intensity of the X-ray spectral lines, which are emitted by the secondary excitation of chemical elements. The primary X-ray beam, which is generated by the light pipe, is irradiated on the specimen. Each chemical element in the specimen is excited, to emit its own secondary characteristic radiation. This secondary ray reaches the spectroscopic crystal, through the collimator. Only the radiation of a specific wavelength, that satisfies the diffraction conditions, is strengthened when it exits the crystal, the radiation of other wavelengths is weakened. This method is based on Bragg's theorem, namely formula (1): Where: n - Diffraction order; λ - The wavelength of the incident beam (characteristic radiation), in nanometers (nm); d - Spacing between crystal planes, in centimeters (cm); θ - The angle between the incident light and the crystal plane, in degrees (°). In quantitative analysis, first measure the analytical line intensity of a series of standard samples; draw a standard curve of intensity versus concentration; perform the necessary mathematical correction for matrix effects; then calculate the element content, according to the intensity of the element spectral lines in the analytical specimen. 4 Instruments and materials 4.1 Wavelength dispersive X-ray fluorescence spectrometer, Rh target light tube (refer to Appendix A, for instrument parameter settings). 4.2 Vibration mill (including tungsten carbide grinding disc). 4.3 Tablet press (including press ring), which can provide 40 t pressure. 4.4 Balance: Sensitivity is 0.1 g. 4.5 Binder: Boric acid or starch (analytical pure). 4.6 Lining agent: Boric acid (industrial pure). 4.7 Triethanolamine (Analytical pure). 5 Specimens The specimen shall be able to pass through a 0.149 mm standard sieve. 6 Steps 6.1 Sample Weigh 15.0 g of specimen (5). Add 3.0 g of binder (4.5) and 3 drops of triethanolamine (4.7). Vibrate and grind on the vibrating mill (4.2), until the specimen can pass through a 0.074 mm standard sieve. Place a pad lining agent (4.6) under the bottom or wrap the edge or place it in the pressure ring, which is then put into the tablet press (4.3). The pressure is 30 t. The holding time is 30 s. After the pressure is released, take out the sample. Blow off the surface impurities to prepare for testing. The sample thickness shall not be less than 4 mm. 6.2 Number of measurements Carry out two measurements independently. Take the average value. 6.3 Instrument calibration 6.3.1 Background correction One or two backgrounds can optionally be measured, for constant elements. 6.3.2 Instrument drift correction Correct the instrument drift, by measuring monitored samples. 6.4 Drawing of calibration curve Select industrial silicon standard samples, to draw a standard curve. Each element shall have a standard series, which have a sufficient content range and a certain gradient. The curve is drawn according to the requirements of the instrument. When drawing, it shall consider the spectral lines of other elements, which may interfere with the spectral lines of each analyzed element. See Appendix B for common interfering element spectral lines. Standard sample is prepared, according to step 6.1; the measurement is carried out, according to 6.5.3. 6.5 Measurement 6.5.1 Preparation Preheat the X-ray fluorescence spectrometer (4.1), until it is stable. Select working parameters, according to the model of X-ray fluorescence spectrometer. 6.5.2 Measurement of monitored samples Set the monitored sample name. Measure the X-ray intensity of the analyzed elements in the monitored sample. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.