HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (17 Jan 2026)
Path: Home > GB > Page125 > GB 26875.6-2011                   Home > Standard_List > GB > Page125 > GB 26875.6-2011

GB 26875.6-2011 English PDF

US$159.00 ยท In stock
Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 26875.6-2011: [GB/T 26875.6-2011] Remote-monitoring system of urban fire protection -- Part 6: Functional requirements of information management software
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 26875.6-2011English159 Add to Cart 2 days [Need to translate] [GB/T 26875.6-2011] Remote-monitoring system of urban fire protection -- Part 6: Functional requirements of information management software Valid GB 26875.6-2011

PDF similar to GB 26875.6-2011


Standard similar to GB 26875.6-2011

GB 20517   GB 15322.1   GB 14287.3   GB/T 26875.7   GB/T 26875.8   GB 26875.1   

Basic data

Standard ID GB 26875.6-2011 (GB26875.6-2011)
Description (Translated English) [GB/T 26875.6-2011] Remote-monitoring system of urban fire protection -- Part 6: Functional requirements of information management software
Sector / Industry National Standard
Classification of Chinese Standard C81
Classification of International Standard 13.220.20
Word Count Estimation 6,656
Date of Issue 2011-07-29
Date of Implementation 2012-05-01
Quoted Standard GB/T 17544-1998; GB/T 26875.4-2011; GB 50440
Regulation (derived from) Announcement of Newly Approved National Standards No. 12 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Chinese standard relates to city fire remote monitoring system, information system and customer service system, information management software, terminology and definitions, functional requirements and test methods. This standard applies to the city fire remote monitoring system information query system and user service systems of information management software.

GB 26875.6-2011: [GB/T 26875.6-2011] Remote-monitoring system of urban fire protection -- Part 6: Functional requirements of information management software


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Remote-monitoring system of urban fire protection.Part 6. Functional requirements of information management software ICS 13.220.20 C81 National Standards of People's Republic of China City fire remote monitoring system Part 6. information management software functional requirements Part 6. Functionalrequirementsofinformationmanagementsoftware Issued on. 2011-07-29 2012-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

Part 4, Chapter 5 are mandatory, the rest are recommended. GB 26875 "city fire remote monitoring system" is divided into six parts. --- Part 1. User information transfer means; --- Part 2. Communications server software functionality requires; --- Part 3. alarm transmission network communication protocol; --- Part 4. Basic data items; --- Part 5. admissibility software functional requirements; --- Part 6. information management software functional requirements. This section GB of Section 626 875. This section drafted in accordance with GB/T 1.1-2009 given rules. This part of the National Fire Fire Communications Standardization Technical Committee Technical Committee (SAC/TC113/SC14) centralized. This section is responsible for drafting unit. Shenyang Fire Research Institute Ministry of Public Security. Participated in the drafting of this section. Wansheng (China) Technology Co., Ltd., Gulf Fire Network Limited, Shenyang Mabel Control Co., Tongfang Co., Ltd., Guangdong 100 Xun Information Technology Co., Ltd., Shanghai VTech Communications, Fujian Shengan development of urban security information Ltd., Beijing Science and Technology Development Co., Ltd. Qingdao WebEx. The main drafters of this standard. Fan Yufeng, put Xu, Zhang Di, JIANG Xue Yun, Liu Haixia, Du Yang, Jia Genlian, Yim, Zhao Xiaobo, Liang Weifeng, Chen Xingyu, right Feng Hui, Zhang Jun. City fire remote monitoring system Part 6. information management software functional requirements

1 Scope

GB 26875 of the provisions of this part of the city fire remote monitoring system, information system and customer service information management system software Member terms and definitions, functional requirements and test methods. This section applies to the city fire remote monitoring system, information system and customer service information management system software.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 17544-1998 Information technology - Software packages - Quality requirements and testing GB/T 26875.4-2011 city fire remote monitoring system - Part 4. Basic data items GB 50440 city fire remote monitoring system technical specifications

3 Terms and Definitions

GB 50440 and defined by the following terms and definitions apply to this document. 3.1 Users users Can use information management software to access the city fire remote monitoring system personnel information, including. user monitoring center, police Fire Department Users and user networking unit door. 3.2 Management manage Realize the city fire remote monitoring system information query, add, update, and delete operations.

4 Basic requirements

Information Management software should meet the following basic requirements. a) the use of Chinese software interface should display; b) the software should not be an exception occurs during operation; User documentation c) software should meet GB/T 17544-1998 of 3.2 requirements.

5 Functional requirements

5.1 information management software should have user rights management, user rights division should contain at least the following permission levels. a) Information Management Software user management; b) inquiry information monitoring center; c) information management monitoring center; d) inquiry networking unit information; e) management information networking units; f) The networking unit information inquiries; g) management of the networking unit information; h) Chagang networked units on duty. 5.2 information management software should have Chagang function. 5.3 information management software should have user rights by different management control center features the following information. a) monitoring center information, the information shall comply with GB/T 26875.4-2011 requirements of Table 1; b) the monitoring center personnel information, the information shall comply with GB/T 26875.4-2011 Table 2 requirements; c) fire laws and regulations, information should meet GB/T 26875.4-2011 Table 13 requirements; d) fire-fighting common sense information, the information shall comply with GB/T 26875.4-2011 Table 14 requirements. 5.4 information management software should have different user privileges, network management functions users the following information. a) Basic information for networking information, the information shall comply with GB/T 26875.4-2011 Table 3 requirements; b) networking units built structures information, the information shall comply with GB/T 26875.4-2011 Table 4 requirements; c) Networking unit of fire safety key parts of the information, the information shall comply with GB/T 26875.4-2011 requirements of Table 5; d) networking unit of fire information facilities, information should meet GB/T 26875.4-2011 Table 6 requirements; e) networking component information unit fire facilities, information should meet GB/T 26875.4-2011 Table 7 requirements; f) networking unit receiving the alarm information, the information shall comply with GB/T 26875.4-2011 Table 8 requirements; g) networking unit Chagang information, the information shall comply with GB/T 26875.4-2011 Table 9 requirements; h) networking unit fire information, the information shall comply with GB/T 26875.4-2011 Table 10 requirements; i) Networking Unit fire equipment inspection information, the information shall comply with GB/T 26875.4-2011 Table 11 requirements; j) networking unit fire facilities maintenance information, and information should meet GB/T 26875.4-2011 Table 12 requirements. 5.5 information management software should have classified retrieval, statistical functions, and can generate corresponding statistics. For a networked fire alarm signal unit Information and running status of fire safety facilities should be able to make a single or a joint search and statistics according to the following search terms. a) date; b) Name of networking; c) networking unit category; d) networking unit to your area; e) regulatory level networking units; f) categories of buildings; g) the nature of use of the building; h) the type of building structure; i) the type of building fire protection facilities; j) building fire facilities component type; k) building fire manufacturer's name; l) building fire facilities maintenance vendor name. 5.6 information management software should have the capabilities for archiving and print statistical reports generated 5.5.

6 Test methods

6.1 General 6.1.1 The manufacturer shall provide information management software packages and user documentation. 6.1.2 before the test, in accordance with the relevant requirements of the user documentation for hardware configuration and software installation, connection-related system equipment, complete software, each Entry is set so that the relevant system equipment in proper working condition. 6.1.3 before the test, should be added or the system is running, etc. generated manually, in GB/T 26875.4-2011 provisions of all data Table, there are no less than 10 data. 6.1.4 shall be in accordance with the provisions of 5.1, in the database to establish user permissions city fire remote monitoring system, the user privilege levels less than A. 6.1.5 Information Management Software functional testing process by the method of 6.2, with reference to the corresponding user documentation process operation carried out one by one. 6.1.6 meet the following requirements of the software under test is qualified, otherwise unqualified. a) during the test measured the software to meet the requirements of Chapter 4; b) tested software is not an exception occurs during the test; The computer running the software under test c) during the test does not restart, do not dawdle (dead) machine; d) information management software function test results shall meet the requirements of Chapter 5. 6.2 Method 6.2.1 operating information management software, observe and record the information management software into operation situation. See text messages 6.2.2 Interface situation information management software. 6.2.3 respectively different permissions user login information management software and see its operation status of information, observe and record operating results. 6.2.4 with the 5.1 h) level user permission to log information management software, networking units on duty remotely Chagang, observe and record Operating results. 6.2.5 respectively of 5.1 b) and c) level user permission to log information management software, management 5.3 a), b), c) and d) information, Outlook Observe and record operating results. 6.2.6 respectively in 5.1 d), e), f) and g) level permissions user login information management software, management 5.4 a), b), c), d), e), f), g), h), i) and j) information, observe and record operating results. 6.2.7 respectively in 5.1 d), e), f) and g) level permissions user login information management software, according to 5.5 a), b), c), d), e), f), g), h), i), j), k) and l) of the fire alarm and fire-fighting facilities operating status information networking units were single or joint entry index Statistics, observe and record the result of the operation. 6.2.8 6.2.7 observe and document the results of the query statistics archiving and printing.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 26875.6-2011_English be delivered?

Answer: Upon your order, we will start to translate GB 26875.6-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 26875.6-2011_English with my colleagues?

Answer: Yes. The purchased PDF of GB 26875.6-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information