|
US$319.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 22601-2008: [GB/T 22601-2008] 2, 4-D butyl emulsifiable concentrates Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 22601-2008 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
[GB/T 22601-2008] 2, 4-D butyl emulsifiable concentrates
| Valid |
GB 22601-2008
|
PDF similar to GB 22601-2008
Basic data | Standard ID | GB 22601-2008 (GB22601-2008) | | Description (Translated English) | [GB/T 22601-2008] 2, 4-D butyl emulsifiable concentrates | | Sector / Industry | National Standard | | Classification of Chinese Standard | G25 | | Classification of International Standard | 65.100.20 | | Word Count Estimation | 12,152 | | Date of Issue | 2008-12-17 | | Date of Implementation | 2009-06-01 | | Adopted Standard | FAO 1.3/EC/S/F-1992, NEQ | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 21 of 2008 (No. 134 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Chinese standard specifies the 2, 4 butylate EC requirements, test methods and marking, labeling, packaging, storage and transportation. This standard applies to the 2, 4 Butyl original drug is dissolved in a suitable solvent and emulsifier in the preparation of 2, 4 butylate EC. |
GB 22601-2008: [GB/T 22601-2008] 2, 4-D butyl emulsifiable concentrates---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
2, 4-D butyl emulsifiable concentrates
ICS 65.100.20
G25
National Standards of People's Republic of China
2,4-D butyl EC
Posted 2008-12-17
2009-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
The standard Chapter 3, Chapter 5 is mandatory, the rest are recommended.
The FAO standards and specifications 1.3/EC/S/F (1992) "2,4-Destersemulsifiableconcentrates" degree of consistency
Non-equivalent.
Appendix A of this standard is an informative annex.
Since the implementation of this standard, the original chemical industry standard HG2320-1992 "2,4- butylate EC" void.
The standard proposed by China Petroleum and Chemical Industry Association.
This standard by the National Standardization Technical Committee on Pesticides (SAC/TC133) centralized.
This standard is drafted by. Shenyang Chemical Research Institute.
Participated in the drafting of this standard. Dalian Songliao Chemical Co., Ltd., Shandong Weifang Rainbow Chemical Co., Ltd., Jiamusi Heilong Pesticide Chemical
Co., Ltd., Wing Tai Fung Changzhou Chemical Co., Ltd.
The main drafters of this standard. Meibao Gui, Xing Jun, Miao innovation, in bright, Hou Yongsheng Dong Xia, Fang Yun, Chen. Yanggui Qin, Du Jianping.
2,4-D butyl EC
Other name, structural formula and basic physicochemical parameters of the active ingredient 2,4-D butyl ester product as follows.
ISO common name. 2,4-Dbutyl
Chemical Name. 2,4-dichlorophenoxyacetic acid, n-butyl
Structural formula
Handkerchief handkerchief handkerchief
Division division division
division division division
Cl
Cl
O CH 2
O CH 2 CH 2 CH 2 CH 3
Empirical formula. C12H14C12O3
Molecular weight. 277.15 (according to 2007 international relative atomic mass)
Biological activity. Herbicides
1 Scope
This standard specifies the 2,4-butyl EC requirements, test methods and marking, labeling, packaging, storage and transportation.
This standard applies to the 2,4-D butyl ester original drug and preparation of the emulsifier is dissolved in a suitable solvent 2,4-D butyl EC.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1600 Determination of Water Pesticides
Determination of GB/T 1601 Pesticides pH value
GB/T 1603 Determination of emulsion stability of pesticide
GB/T 1604 Goods pesticide regulations for acceptance
GB/T 1605-2001 Sampling Method commercial pesticides
GB/T 4472 chemical product density, relative density measurement General
GB 4838 EC pesticide packaging
GB/T 19136 Determination of Pesticide Thermal storage stability
GB/T 19137 Pesticide cryogenic stability Determination
3 Requirements
3.1 Composition and appearance
This product should meet the standards of the original drug 2,4-butyl ester prepared as a homogeneous oily liquid without visible suspended matter and sediment.
3.2 Technical Specifications
2,4-D butyl EC shall comply with the requirements of Table 1.
Table 1 2,4-D butyl EC indicators Control Project
project
index
57% 72% 900g/L 999g/L
Butyl 2,4 mass fraction of a /%
Or 2,4-D butyl ester concentration (20 ℃) / (g/L)
57.0 + 2.5-2.5
72.0 + 2.5-2.5
76.0 + 2.5-2.5
+ 25-25 900
82.5 + 2.5-2.5
+ 25-25 999
Free phenol content (2,4-DCP meter) /% ≤ 0.6 0.8 0.8 0.9
Moisture content /% ≤ 0.8
pH range of 3.0 to 7.0
Emulsion stability (diluted 200 times) Qualified
Low temperature stability Qualified b
Thermal storage stability b qualified
When a dispute occurs when the mass to the mass fraction of arbitration.
b low temperature stability test, the thermal storage stability tests at normal production, at least every three months, once detected.
Test Method 4
4.1 Sampling
According to GB/T 1605-2001 in "liquid formulations sampling" approach. Determined by sampling a random number table method packages, the final sample size
Not less than 200mL.
4.2 Identification Test
Gas Chromatography --- The identification test can be carried out simultaneously with the determination of 2,4-D butyl ester content. Under the same chromatographic operating conditions, the test
The retention time of the sample solution and the standard solution to a peak of 2,4-D butyl ester peak retention time, the relative difference should be 1.5%
Fewer.
4.3 Determination of the mass fraction of 2,4-D butyl ester
4.3.1 Method summary
Sample was dissolved in chloroform, di-isobutyl phthalate as internal standard, the use of polyethylene terephthalate and tetrachlorophthalic
Apiezon L is a stainless steel column filler and a flame ionization detector, the sample of 2,4-butyl gas chromatography and measurement
set. Determination can also be used by capillary gas chromatography, chromatographic operating conditions given in Appendix A.
4.3.2 Reagents and solutions
Chloroform;
2,4-D butyl standard. a known mass fraction ≥98.0%;
Internal standard. di-iso-butyl phthalate, should not interfere with the analysis of impurities;
Internal standard solution. Weigh isobutyl phthalate 3.5g, set 250mL flask, add appropriate amount of chloroform was dissolved and diluted to
Mark and shake.
4.3.3 Instruments
Gas chromatograph. with a hydrogen flame ionization detector;
Chromatography or chromatography workstation processor;
Column. 2m × 3mm (i.d.) Stainless steel (glass) columns, built-in 1.7% tetrachlorophthalic polyethylene terephthalate and 0.3% Appius
Song L/ChromosorbW-AWDMCS180 ~ 250μm filler;
Micro injector. 10μL.
4.3.4 GC operating conditions
Temperature (℃). Column temperature. 170, 260 gasification chamber, the detector chamber 260;
Gas flow rate (mL/min). carrier gas (N2) 20, hydrogen gas 30, air 300;
Injection volume. 0.6μL;
Retention time (min). 2,4- 11.0 butylate, internal standard 6.7.
It said operating parameters are typical, according to the characteristics of different instruments, given operating parameters adjusted as appropriate, in order to obtain the best results.
A typical gas chromatogram of 2,4-D butyl EC and the internal standard is shown in Figure 1.
1 --- internal standard;
2 --- 2,4-D ester.
Figure 1 Gas chromatograms butyl 2,4-EC and the internal standard
4.3.5 measuring step
4.3.5.1 Preparation of standard solution
Weigh 2,4-butyl standard 0.1g (accurate to 0.0002g), placed in a glass bottle stuffed with a pipette 5mL internal standard solution
Liquid, shake.
4.3.5.2 Preparation of sample solution
Weigh containing 2,4-D butyl ester 0.1g (accurate to 0.0002g) sample, placed in a glass vial stopper, and 4.3.5.1 with the same
Pipette internal standard solution 5mL, shake.
4.3.5.3 Determination
Under these operating conditions, after the instrument is stable, continuous injection of several doses of the standard solution until the two adjacent needle relative peak area of 2,4-butyl
After the change is less than 1.2%, according to the solution, the sample solution, the sample solution and standard sequence of the standard solution was measured.
4.3.5.4 Calculation
The ratio measured before and after the two-needle sample solution and two doses of the standard sample solution of 2,4-butyl and the internal standard peak area, respectively
average. Sample mass fraction of 2,4-D butyl ester 1 (%) according to equation (1) calculation of the concentration of 2,4-D butyl ρ1 (g/L) according to equation (2)
Calculated.
(1)
ρ1 =
(2)
Where.
Density ρ --- 20 ℃ when the sample in grams per milliliter (g/mL) (according to GB/T 4472 measured);
--- Standard samples of 2,4-butyl ester content, expressed as a percentage.
4.3.6 allowable difference
2,4-D butyl ester content (mass concentration) of two parallel determination results relative difference should be less than 1.5%, and the arithmetic mean for
To determine the results.
4.4 Determination of free phenols
4.4.1 Method summary
The sample was dissolved in ethanol, ammonia, 4-amino-antipyrine and potassium ferricyanide solution color, absorbance was measured at 520nm place.
Isolated from the calibration curve of standard sample absorbance at the same volume, calculated free phenol content.
4.4.2 Reagents and solutions
2,4-dichlorophenol standard. a known mass fraction ≥98.0%;
Ethanol;
Isopropanol;
Ethanol, isopropyl alcohol solution. ψ (ethanol. isopropanol. water) = 2.1.3;
Ammonia solution. Ba (NH3 · H2O) = 0.1mol/L;
2,4-DCP standard solution. Weigh 2,4-dichlorophenol standard 0.01g (accurate to 0.0002g), placed in 100mL volumetric flask, add
A small amount of ethanol to dissolve, diluted with ethanol to the mark;
4-amino-antipyrine solution. ρ = 2g/L;
Ferricyanide solution. ρ = 4g/L.
4.4.3 instruments and equipment
Spectrophotometer;
Microburette. 2mL;
Stoppered cylinder. 30mL;
Quartz cuvette. 1cm.
4.4.4 measuring step
4.4.4.1 Correction
Followed by microburette draw 0.2mL, 0.5mL, 0.8mL, 1.0mL, 1.2mL, 1.5mL, 2.0mL2,4- dichlorophenol standard
Sample solution, adding seven stoppered graduated cylinder, fill with ethanol was added to 10mL, then followed by adding 5mL of isopropanol, 5mL ammonia solution, 5mL4- ammonia
Karthikeyan antipyrine 5mL aqueous potassium ferricyanide solution. Each addition are required to shake, and the last intense shaking 1min, standing
5min. Quartz cuvette, ethanol isopropyl alcohol solution as the reference absorbance at 520nm measured.
Draw 10mL ethanol, according to the procedure described above was added to each solution, determine the reagent blank absorbance.
Blank value is subtracted from the phenol solution absorbance measured absorbance, the corresponding volume of phenol solution was plotting a calibration curve.
4.4.4.2 Determination
Weigh containing 2,4-D butyl ester 0.2g (accurate to 0.0002g) sample, placed in 100mL flask, add a small amount of ethanol solution
Solution, dilute to the mark with ethanol. With a pipette to the solution of 10mL stoppered measuring cylinder and then followed by adding 5mL of isopropanol, 5mL
Ammonia solution, 5mL4- amino antipyrine 5mL aqueous potassium ferricyanide solution. Each addition are required to shake, and the last intense shaking
1min, standing 5min. Quartz cuvette, ethanol isopropyl alcohol solution as the reference absorbance at 520nm measured. Minus empty
After the absorbance values of white, from the calibration curve of the absorbance corresponding to 2,4-DCP standard solution volume (mL) to detect.
2 free phenol content (%) according to equation (3) Calculated.
(3)
Where.
Vp --- measured absorbance of the sample corresponding to the volume of phenol solution in milliliters (mL);
--- Sample mass fraction of 2,4-dichlorophenol in%.
4.5 Determination of Moisture
According to GB/T 1600 the "Karl Fischer method".
According to GB/T 1601 carried out.
4.7 Emulsion stability test
Standard hard water sample was diluted 200-fold, according to GB/T 1603 test, the non-oil slick, no precipitation under qualified.
4.8 Low temperature stability test
According to GB/T 19137 in "homogeneous emulsion and liquid preparations", in the bottom of the centrifuge tube educt volume does not exceed 0.3mL qualified.
4.9 Thermal storage stability test
According to GB/T 19136 in "liquid formulation" to. After the thermal storage, 2,4-D butyl ester content should not be lower than the measured mass fraction before hot storage
95% emulsion stability should continue to meet the standards.
4.10 Product inspection and acceptance
Shall comply with GB/T 1604's. Limit the use of numerical treatment rounding value comparison method.
5 marking, labeling, packaging, storage and transportation
5.1 2,4-D butyl EC marking, labeling and packaging should comply with the provisions of GB 4838.
5.2 2,4-D butyl EC Bulk or polyurethane with iron drum, barrel net content of not more than 200kg. 2,4-D butyl EC parcel
Loaded polyester bottle or glass bottles, bottle net weight 100g (mL), 200g (mL), 250g (mL), 500g (mL),
1kg (1L); overpack Plastic boxes or corrugated boxes, each box of net weight shall not exceed 15kg.
5.3 Other forms of packaging may be used according to user requirements or the order agreement, it should comply with the provisions of GB 4838.
5.4 2,4-D butyl EC packages should be stored in well-ventilated, dry coffers.
5.5 storage, prevent moisture and sunlight, no food, seed, feed mix, avoid contact with skin, eyes, mouth and nose to prevent inhalation.
5.6 Security. 2,4-D butyl ester as a low toxicity herbicides, inhalation can cause headache, nausea. The FDA should wear protective equipment, after application
Wash with soap, if ingested, immediately sent to hospital.
5.7 Warranty. under the specified storage conditions, warranties of 2,4-D butyl EC, from date of manufacture for 2 years.
Appendix A
(Informative)
2,4-D butyl ester content by capillary gas chromatographic method
A. 1 Method summary
Sample was dissolved in chloroform, di-n-butyl phthalate as the internal standard, using a HP-5 capillary column as filler and flame
Ionization detector, the sample of 2,4-butyl ester by gas chromatography separation and determination.
A. 2 Reagents and solutions
Chloroform;
2,4-D butyl standard. a known mass fraction ≥98.0%;
Internal standard. di-n-butyl phthalate, should not interfere with the analysis of impurities;
Internal standard solution. Weigh-n-butyl phthalate 3.5g, set 250mL flask, add appropriate amount of chloroform was dissolved and diluted to
Mark and shake.
A. 3 Instrument
Gas chromatograph. with a hydrogen flame ionization detector;
Chromatography or chromatography workstation processor;
Column. 30m × 0.32mm (. I.d) capillary column bonded HP-5 (5% phenyl methyl silicone), a film thickness of 0.25μm.
A. 4 GC operating conditions
Temperature (℃). Column temperature.200, 250 gasification chamber, the detector chamber 300;
Gas flow rate (mL/min). carrier gas (N2) 1.8, hydrogen gas 30, air 300; 25 compensation gas;
Injection volume. 1.0μL;
Retention time (min). 2,4- butylate 9.0, internal standard 11.6.
GC operating conditions described above, the Department of typical operating parameters. According to the characteristics of different instruments, given operating parameters adjusted as appropriate,
In order to obtain the best results. Typical 2,4-D butyl EC gas chromatography is shown in Figure A. 1.
1 --- 2,4-butyl;
2 --- internal standard.
Figure A. 1 2,4-D butyl EC gas chromatogram
A. 5 measuring step
A. 5.1 preparation of standard solution
Weigh 2,4-butyl standard 0.1g (accurate to 0.0002g), placed in a glass bottle with a stopper with a pipette 5mL internal standard solution,
Shake well.
A. 5.2 Sample preparation solution
He said sample containing 2,4-D butyl taking about 0.1g (accurate to 0.0002g), and placed in a stoppered glass vial with pipette 5mL within
Standard solution, shake.
A. 5.3 Determination
Under these operating conditions, the instrument until a stable baseline, the number of continuous injection doses of the standard solution, calculated for each needle 2,4-butyl and the internal standard peak
The ratio of the area of repetitive until two adjacent needles 2,4-butyl relative change compared with the internal standard peak area of less than 1.2%, the solution in accordance with standards
Solution, sample solution, the sample solution and standard solution were sequentially measured.
A. 6 Calculation
The ratio measured before and after the two-needle sample solution and two doses of the standard sample solution of 2,4-butyl and the internal standard peak area, respectively
average. Sample mass fraction of 2,4-D butyl ester 1 (%), according to equation (A.1) to calculate the mass concentration ρ1 (g/L) according to equation (A.2) Calculated.
(A.1)
ρ1 =
(A.2)
Where.
Density ρ --- 20 ℃ when the sample in grams per milliliter (g/mL) (according to GB/T 4472 measured);
--- Standard samples of 2,4-butyl ester content, expressed as a percentage.
A. 7 allowable difference
Two parallel determination results of the relative difference should be less than 1.5%, the arithmetic mean value as a measurement result.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 22601-2008_English be delivered?Answer: Upon your order, we will start to translate GB 22601-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 22601-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB 22601-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|