HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (29 Sep 2024)

GB/T 38211-2019 PDF in English


GB/T 38211-2019 (GB/T38211-2019, GBT 38211-2019, GBT38211-2019)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 38211-2019English170 Add to Cart 0-9 seconds. Auto-delivery. Sulfuryl fluoride Valid
Standards related to (historical): GB/T 38211-2019
PDF Preview

GB/T 38211-2019: PDF in English (GBT 38211-2019)

GB/T 38211-2019 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 65.100.10 G 25 Sulfuryl fluoride 硫酰氟 ISSUED ON: DECEMBER 10, 2019 IMPLEMENTED ON: JULY 01, 2020 Issued by: State Administration for Market Regulation; Standardization Administration of the People's Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Requirements ... 4  4 Test methods ... 5  5 Acceptance and quality assurance period ... 9  6 Signs, labels, packaging, storage and transportation ... 10  Annex A (informative) Other names, structural formulas and basic physicochemical parameters of sulfuryl fluoride ... 11  Sulfuryl fluoride 1 Scope This Standard specifies the requirements, test methods, acceptance, quality assurance period and signs, labels, packaging, storage and transportation for sulfuryl fluoride. This Standard applies to sulfuryl fluoride consisting of sulfuryl fluoride and impurities generated in its production. NOTE: See Annex A for other names, structural formulas and basic physicochemical parameters of sulfuryl fluoride. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 190, Packing symbol of dangerous goods GB/T 1604, Commodity pesticide regulations for acceptance GB/T 1605-2001, Sampling method for commodity pesticides GB 3796, General rule for packing of pesticides GB/T 6681, General rules for sampling gaseous chemical products GB/T 6682-2008, Water for analytical laboratory use - Specification and test methods GB/T 8170-2008, Rules of rounding off for numerical values and expression and judgement of limiting values GB 15603, Rule for storage of chemical dangers GB 17916, Specifications for storage and preservation of toxic goods 3 Requirements 3.1 Appearance It is colorless and odorless gas at normal temperature and pressure. It is a colorless homogeneous liquid under pressure or freezing. 3.2 Technical indicators Sulfuryl fluoride shall also meet the requirements of Table 1. 4 Test methods WARNING -- Persons using this Standard shall have practical experience in laboratory work. Determination of pH value shall be carried out in a fume hood. This Standard does not address all safety issues. It is the user's responsibility to take appropriate safety and health measures and to ensure compliance with the relevant state regulations. 4.1 General provisions Unless other requirements are specified, the reagents and water used in this Standard refer to the analytically pure reagents and grade three water specified in GB/T 6682- 2008. The determination of the inspection results shall be carried out according to 4.3.3 in GB/T 8170-2008. 4.2 Sampling Conduct according to GB/T 6681 and 5.3.4 in GB/T 1605-2001. Use random sampling method to take samples from ay steel cylinder for each batch of products. The sampling volume shall not be less than 300mL (the cylinder pressure shall not be less than 5.0MPa, and the filling factor shall be 1.0kg/L). 4.3 Identification test Infrared spectroscopy -- There shall be no obvious difference between the infrared absorption spectra of the specimen and the sulfuryl fluoride standard gas in the range of 1800cm-1~400cm-1. The infrared spectrum of sulfuryl fluoride standard gas is shown in Figure 1. 100 (or other chromatographic columns with the same column efficiency). Sample injector: 5mL. 4.4.4 Preparation of chromatographic column 4.4.4.1 Application of fixative Weigh 0.5g of polychlorotrifluoroethylene wax. Use ether or acetone to dissolve in the beaker. Pour 25g of carrier and mix well. Dry under infrared light for later use. 4.4.4.2 Packing of chromatographic column Connect a small funnel to the outlet of the washed and dried chromatographic column. Fill the column with the prepared packing in batches. At the same time, tap the column wall continuously until the packing is 1.5cm away from the column outlet. Move the funnel to the inlet of the column. Plug a small dollop of silanized glass wool at the outlet end. Connect it to vacuum pump via rubber hose. Turn on the vacuum pump. Continue to slowly add the packing. Keep tapping on the column wall. Pack it evenly. The packing is completed. Stuff a small dollop of glass wool at the inlet end. Squeeze properly to keep stuffing from moving. (Or purchase other chromatographic columns with the same column efficiency). 4.4.4.3 Aging of chromatographic column Connect the column inlet end to the vaporizer. The outlet end is temporarily not connected to the detector. Pass the carrier gas at a flow rate of 15mL/min. Rise the temperature to 150°C in several stages. At this temperature, conduct at least 24h aging. 4.4.5 Operating conditions of gas chromatography Temperature (°C): 100 for column temperature, 150 for gasification chamber, 150 for detector chamber. Carrier gas flow rate (mL/min): 30. Injection volume (mL): 2. Retention time (min): 0.8 for air, 1.3 for carbon dioxide, 1.7 for sulfuryl fluoride, 4.3 for chlorine, 4.8 for water, 6.9 for sulfur dioxide, 8.9 for sulfuryl chloride fluoride. Stop time (min): 20. The above operating conditions of gas chromatography are typical operating parameters. According to the characteristics of different instruments, the given operating parameters can be properly adjusted, so as to obtain the best results. A typical sulfuryl fluoride gas chromatogram is shown in Figure 2. ΣAi - The sum of the peak areas of all component chromatographic peaks (excluding the air peak). 4.4.8 Tolerance The difference between the two parallel determination results of sulfuryl fluoride volume fraction shall not be greater than 0.2%. Take the arithmetic mean as the determination result. 4.5 Determination of pH value 4.5.1 Test instruments Porous gas washing bottle: 250mL. Balance: the accuracy is 0.01g. Acidity meter: the division value of pH is 0.01. 4.5.2 Determination steps Add 100mL of carbon dioxide-free distilled water to the gas washing bottle. Connect the washing bottle to the sampling cylinder with a rubber tube. Then place the cylinder on the balance. Control the flow rate of the absorbed gas to be about 300mL/min, that is, about 1g/min. Inject 1g of sulfuryl fluoride gas. Then use the pH meter to measure the pH of the solution in the absorption bottle. 4.5.3 Tolerance The difference between the results of three parallel determinations of pH value shall not be greater than 0.2. Take the arithmetic mean value as the determination result. 5 Acceptance and quality assurance period 5.1 Acceptance It shall comply with the provisions of GB/T 1604. 5.2 Quality assurance period Under the specified storage and transportation conditions, the quality assurance period of sulfuryl fluoride is 2 years from the production date. During the quality assurance period, all indicators shall meet the standard requirements. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.