US$319.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 20041.23-2009: [GB/T 20041.23-2009] Conduit systems for cable management -- Part 23: Particular requirement -- Flexible conduit systems Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 20041.23-2009 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
[GB/T 20041.23-2009] Conduit systems for cable management -- Part 23: Particular requirement -- Flexible conduit systems
| Valid |
GB 20041.23-2009
|
PDF similar to GB 20041.23-2009
Basic data | Standard ID | GB 20041.23-2009 (GB20041.23-2009) | | Description (Translated English) | [GB/T 20041.23-2009] Conduit systems for cable management -- Part 23: Particular requirement -- Flexible conduit systems | | Sector / Industry | National Standard | | Classification of Chinese Standard | K65 | | Classification of International Standard | 29.120.10 | | Word Count Estimation | 12,116 | | Date of Issue | 2009-05-06 | | Date of Implementation | 2010-02-01 | | Adopted Standard | IEC 61386-23-2002, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 6, 2009 (No. 146 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Chinese standard specifies flexible conduit systems. |
GB 20041.23-2009: [GB/T 20041.23-2009] Conduit systems for cable management -- Part 23: Particular requirement -- Flexible conduit systems ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Conduit systems for cable management.Part 23. Particular requirement.Flexible conduit systems
ICS 29.120.10
K65
National Standards of People's Republic of China
GB 20041.23-2009/IEC 61386-23.2002
Conduit systems for cable management
Particular requirements for flexible conduit systems. Part 23
(IEC 61386-23.2002, IDT)
Posted 2009-05-06
2010-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Definitions 1
4 1 General requirements
5 General conditions for test 1
6 Category 1
7 Marking and documentation 1
8 Size 1
9 Structure 2
Mechanical properties 2 10
11 Electrical Performance 2
12 Thermal Performance 3
13 Flame Effect 3
14 3 External influences
15 3 Electromagnetic Compatibility
Appendix A (normative) Catheter System classification code 6
Material thickness measurement Appendix B (normative) 6
GB 20041.23-2009/IEC 61386-23.2002
Foreword
All technical content in this section is mandatory.
GB 20041 "Conduit systems for cable management" is divided into two parts.
--- Part 1. General requirements (GB/T 20041.1)
--- Part 2. Particular requirements (GB 20041.21 ~ 20041.24)
● Part 21. Particular requirements for rigid conduit systems
● Part 22. Particular requirements for flexible conduit systems
● Part 23. Particular requirements for flexible conduit systems
● Part 24. Particular requirements for conduit systems buried underground
This is Part 23 of GB 20041. This section should be GB/T 20041.1-2005 used in conjunction.
This section identical with IEC 61386-23.2002 (first edition) "Conduit systems for cable management - Part 22. flexible conduit special
Claim".
This section of the Appendix A, Appendix B is a normative appendix.
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee electrical accessories.
This section drafted by. China Electric Apparatus Research Institute, Guangdong CIQ, Foshan Gaoming Gu Plastic Co., Ltd. in Hangzhou
Hongyan Electric Co., Ltd., Guangdong Science and Technology Industrial Co., Ltd. Liansu.
The main drafters of this section. Luohuai Ping Yu Xuan, Song Bo, single toward blue, Zhang Lan Chan, Huang Weiling, Tangnian En, Zhao Xia, Zhou Xiaoqing.
GB 20041.23-2009/IEC 61386-23.2002
Conduit systems for cable management
Particular requirements for flexible conduit systems. Part 23
1 Scope
GB/T 20041.1-2005 after this chapter apply for the following modifications.
increase.
This part of GB 20041 specifies the requirements for flexible conduit systems.
2 Normative references
The following documents contain provisions which, through reference in this text, constitute provisions of this part. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this section, however, encourage the parties to this part of the research agreement
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 20041.1-2005 this chapter apply.
3 Definitions
GB/T 20041.1-2005 this chapter apply.
4 General requirements
GB/T 20041.1-2005 this chapter apply.
5 General conditions for tests
GB/T 20041.1-2005 this chapter apply.
Category 6
Except as follows, GB/T 20041.1-2005 this chapter apply.
6.1.31), 6.1.32) and 6.1.33) Not applicable.
7 Marking and documentation
GB/T 20041.1-2005 after this chapter apply for the following modifications.
increase.
7.1.101 conduit should be identified in accordance with the requirements of 7.1. Logo should at regular intervals along the full length of the catheter, as the most suitable interval
1m, not more than 3m. As in the case of technology can not be implemented, logos can be marked on the label attached to the end product or packaging.
Compliance is checked by inspection.
7.1.102 The manufacturer shall provide documentation for the system or marked on the package, to illustrate the minimum diameter, minimum bend radius and in accordance with Chapter 6
classification.
Compliance is checked by inspection.
Size 8
instead.
GB 20041.23-2009/IEC 61386-23.2002
8.1 Threads shall comply with GB/T 17194.
Compliance is checked by measuring gauge GB/T 17194 stipulated to check.
The minimum inner diameter of 8.2 catheter system shall be declared by the manufacturer.
Compliance is checked by measurement.
9 Structure
GB/T 20041.1-2005 this chapter apply.
10 Mechanical properties
GB/T 20041.1-2005 after this chapter apply for the following modifications.
10.1 mechanical strength
10.1.1 Addition.
Note. very light, flexible catheter should not be considered to have sufficient mechanical protection, and should not be used in building construction.
10.4 Bending test
GB/T 20041.1-2005 this section does not apply.
10.5 bending test
10.5.101 from conduit terminating conduit fittings with the composition of the components according to the manufacturer's instructions assembled, you should use 101 as shown in Fig.
Means for bending test.
10.5.102 test should be used as a conduit 6 samples having a suitable length, three specimens should be minimum transport, use and safety provisions in Table 1
Means test temperature ± 2 ℃ under. Further three samples shall be carried out in Table 2 below the specified maximum transport, use and installation temperature ± 2 ℃ in
test.
Manufacturers can declare a flexible catheter adapted to a predetermined temperature in accordance with Table 1 transport and installation, but only for a minimum temperature of ambient temperature
Bending degree, this time, the test shall be at (20 ± 2) ℃ were, classification code and the first three digits should be X. The manufacturer shall, in its written materials
The transport and installation explicitly stated minimum temperature according to Table 1, the lowest temperature of the ambient temperature and the maximum temperature in accordance with the installation and use
Table 2.
10.5.103 terminating conduit fittings should be used as shown in Fig. 101 is fixed to the specimen swing body, when the catheter is moved to the middle position, the catheter
Axis is vertical, and passing through the pivot shaft. Equipped with a device should be placed after the sample under specified conditions 2h, or until the sample temperature reaches declaration
Degree, whichever is longer.
10.5.104 pendulum should axis vertical axis, swing, swing the total angle of (180 ± 5) °, the average separated by a vertical axis. Components should be
Per minute (40 ± 5) times the rate of 5000 fold. From the vertical position start, once a week sinusoidal movement bent.
10.5.105 After the test, the sample should be no signs of split, nor come now without additional amplification normal or corrected vision visible
crack.
10.6-destructive testing
GB/T 20041.1-2005 this section does not apply.
10.7 Tensile strength
GB/T 20041.1-2005 purpose of this regulation for the following modifications apply.
10.7.3 Replacement.
For no statement has a tensile strength of the catheter system, the tensile strength of the interface should be in accordance with Table 6 Classification 1.
11 Electrical Performance
GB/T 20041.1-2005 after this chapter apply for the following modifications.
11.2 shield ground test.
instead.
GB 20041.23-2009/IEC 61386-23.2002
Catheter samples and terminating conduit fittings shall be specified by the manufacturer and the fixed assembly shown in Figure 103. Components shall pass to 25Aa. c.
Current 60 + 5 0s, current frequency is 50Hz ~ 60Hz, no-load voltage of the power supply does not exceed 12V. Then measured between two o'clock as shown in Fig. 103
Voltage drop, and drop resistance is calculated from the current and voltage.
Resistance not exceeding 0.05Ω.
If you require special devices to connect with the conduit and conduit fittings, these devices should be sufficient to remove the protective coating of the catheter, or should be manufactured
Suppliers provision would remove the protective layer.
12 Thermal Performance
GB/T 20041.1-2005 after this chapter apply for the following modifications.
12.2.4 Replacement.
Then, the load removed, the sample was immediately placed in the vertical direction, so that on the basis of 102 corresponding to the gauge in its own weight and without any
The case of the initial velocity through the conduit, should be able to gauge catheter.
13 flame effect
GB/T 20041.1-2005 this chapter apply.
14 external influences
GB/T 20041.1-2005 this chapter apply.
15 Electromagnetic Compatibility
GB/T 20041.1-2005 this chapter apply.
GB 20041.23-2009/IEC 61386-23.2002
Drawings.
A --- catheter;
B --- Termination accessories;
Minimum bend radius Y --- declared by the manufacturer;
Z --- 1.5 × Y.
1 --- pendulum;
2 --- guide support block;
3 --- a plan view of the guide support block.
Note. The design of this figure can not be limited, subject to the icon size requirements.
101 bending test apparatus of FIG.
GB 20041.23-2009/IEC 61386-23.2002
D manufacturer declares that 80% of the minimum inner diameter of the catheter
Steel materials, hard and polished edges slightly thrown round
Manufacturing tolerances +0.05
0 mm
Tolerance and axial dimensions ± 0.2mm
Allow wear 0.01mm
Note. The figure in addition to the rest of the dimensions shown without design limitations.
Figure 102 checks a minimum inner diameter of the catheter gauge after the impact and the heat test
Drawings.
X = 12mm ± 2mm
1 --- 3mm metal plate;
2 --- optional locking nut;
3 --- By tapping hole or threaded fitting nut to split termination conduit fitting plate;
4 --- catheter.
103 Shield ground test conduit and conduit fittings termination assembly
GB 20041.23-2009/IEC 61386-23.2002
Appendix A
(Normative)
Catheter system of classification codes
Part 1 of this Appendix apply.
Appendix B
(Normative)
Determination of material thickness
Part 1 of this Appendix apply.
GB 20041.23-2009/IEC 61386-23.2002
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 20041.23-2009_English be delivered?Answer: Upon your order, we will start to translate GB 20041.23-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 20041.23-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB 20041.23-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|