GA 159: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GA 159-2011 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Water-based fire retardants
| Obsolete |
GA 159-2011
|
| GA 159-1997 | English | 359 |
Add to Cart
|
3 days [Need to translate]
|
General specifications for water-based fire retardants
| Obsolete |
GA 159-1997
|
PDF similar to GA 159-2011
Standard similar to GA 159-2011 GA 211 GB/T 9978.1 GB/T 7633
Basic data | Standard ID | GA 159-2011 (GA159-2011) | | Description (Translated English) | Water-based fire retardants | | Sector / Industry | Public Security (Police) Industry Standard | | Classification of Chinese Standard | C82 | | Classification of International Standard | 13.220.40 | | Word Count Estimation | 9,939 | | Date of Issue | 2011-11-01 | | Date of Implementation | 2011-12-01 | | Older Standard (superseded by this standard) | GA 159-1997 | | Quoted Standard | GB/T 1936.1; GB/T 3819; GB/T 3923.1; GB/T 5454; GB/T 5455; GB 8624; GB/T 8625; GB/T 8627 | | Regulation (derived from) | Water-based flame retardant treatment agent industry standard revised release; industry standard filing notice No. 4 2012 (No. 148) | | Issuing agency(ies) | Ministry of Public Security | | Summary | This standard specifies the terms and definitions, classification, technical requirements, test procedures, inspection rules, marking, packaging and storage of water-based flame retardants. This standard applies to water-based flame retardant treatment agent. |
GA 159-2011: Water-based fire retardants---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Water-based fire retardants
ICS 13.220.40
C82
People's Republic of China Public Security Industry Standards
Replacing GA 159-1997
Water-based fire-retardant treatment agent
Issued on. 2011-11-01
2011-12-01 implementation
People's Republic of China Ministry of Public Security
Foreword
The standard Chapter 5, Chapter 7 are mandatory, the rest are recommended.
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard is GA 159-1997 "water-based fire-retardant treatment agent General technical conditions" amendments.
This standard compared with GA 159-1997, the main changes are as follows.
--- Revised classification (see Chapter 4, Chapter 3 of the 1997 edition);
--- Modify the content of the technical requirements (see Chapter 5, Section 4 of the 1997 edition);
--- Modified test procedure (see Chapter 6, Chapter 5 of the 1997 edition);
--- Increasing the nonconformity defect classification (see Table 4);
--- Refined flag content requirements (see 8.1, 7.3, 1997).
This standard was proposed by the Ministry of Public Security Fire Department.
This standard by the National Standardization Technical Committee for fire protection material Technical Committee (SAC/TC113/SC7) centralized.
This standard was drafted. Ministry of Public Security of Sichuan Fire Research Institute.
The main drafters. Zhang Yu, Lu Guojian Yu Wei, Songlin, Yu Lijiang, Zhouyou Gui.
This standard replaces the standards previously issued as follows.
--- GA 159-1997.
Water-based fire-retardant treatment agent
1 Scope
This standard specifies the terms and definitions of water-based fire-retardant treatment agent, classification, technical requirements, testing procedures, inspection rules, marking, packaging,
Storage and so on.
This standard applies to water-based fire-retardant treatment agent.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 1936.1 Wood bending strength test method (ISO 3133)
GB/T 3819 Textiles - Determination of the crease recovery angle of recovery (ISO 2313)
GB/T 3923.1 Textiles Tensile properties of fabrics - Part 1. breaking force and elongation Strip method (ISO /
DIS13934-1)
GB/T 5454 Textiles - Burning behavior - Oxygen index method (ISO 4589)
GB/T 5455 Textiles - Burning behavior - Vertical method (JIS1091)
GB 8624 Classification of building materials and combustion products (EN13501-1)
GB/T 8625 flame-retardant building materials test methods (DIN4102)
Smoke density test method combustion or decomposition GB/T 8627 supplies (ASTMD2843)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Water-based fire-retardant treatment agent water-basedfireretardant
Water as the dispersion medium, by spraying or dipping, etc. to make wood, fabric to obtain a certain combustion properties of flame-retardant treatment agent.
3.2
Moisture absorption rate moistureabsorptionrate
Percentage mass due to moisture absorption and increase the quality of its drying retardant treating agent contained in the base material.
3.3
Dry adsorption amount absorptioncapacity
Under the base per kg adsorbed water-based fire-retardant treatment agent (23 ± 2) ℃, relative humidity (45 to 55)% of the state dried to a spacing
The rate of mass change 48h twice before and after weighing no more than ± 0.1% of the mass.
Category 4
Water-based fire-retardant treatment agent using the object can be divided into.
a) a water-based fire-retardant wood treatment agent;
|