GA 211-2009: High temperature-resistant test methods for smoke and heat exhaust ventilators
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Obsolete

GA 211: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GA 211-2009English160 Add to Cart 0-9 seconds. Auto-delivery High temperature-resistant test methods for smoke and heat exhaust ventilators Obsolete
GA 211-1999English199 Add to Cart 3 days High temperature-resistant test methods for fire fan in smoke-venting system Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GA 211-2009
      

Similar standards

GA 211   GB/T 9978.1   GB/T 7633   

GA 211-2009: High temperature-resistant test methods for smoke and heat exhaust ventilators

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GA211-2009
PUBLIC SECURITY INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 13.220.20 C 82 Replacing GA 211-1999 High temperature-resistant test methods for smoke and heat exhaust ventilators ISSUED ON: FEBRUARY 27, 2009 IMPLEMENTED ON: MARCH 01, 2009 Issued by: Ministry of Public Security of PRC

Table of Contents

Foreword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Terms and definitions... 5 4 Requirements ... 6 4.1 Test device ... 6 4.2 Measurement ... 7 4.3 Test and installation requirements for smoke and heat exhaust ventilators ... 7 4.4 High temperature-resistant test requirements for smoke and heat exhaust ventilators . 8 5 Test method ... 10 6 Observation, measurement, recording ... 13 7 Judgment criteria ... 13 8 Test report ... 14 High temperature-resistant test methods for smoke and heat exhaust ventilators

1 Scope

This standard specifies the test device, the ventilator installation, the test method, the judgement criteria, the test report, etc., of the axial-flow (corresponding centrifugal) smoke and heat exhaust ventilator, which has a machine number of not more than No.18, during the high temperature-resistant test in laboratory. For the axial-flow (corresponding centrifugal) smoke and heat exhaust ventilator, which has a machine number of more than No.18 AND is equipped with electric heating test device, it is only subject to the high temperature-resistant test; it does not measure the aerodynamic performance at high temperature, BUT only measures the aerodynamic performance of the ventilator at room temperature. This standard is applicable to the high temperature-resistant performance test of smoke and heat exhaust ventilator, which is installed in industrial and civil buildings, civil air defense projects and other buildings, tunnels, subways.

2 Normative references

The provisions in following documents become the provisions of this Standard through reference in this Standard. For the dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this Standard; however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB/T 1236-2000 Industrial fans - Performance testing using standardized airways (idt ISO 5801:1997) JB/T 8689-1998 Fan vibration detection and its limited value

3 Terms and definitions

The terms and definitions, which are established in GB/T 1236-2000, as well as the following terms and definitions, apply to this standard. 3.1 Smoke and heat exhaust ventilators Stationary electric device, which is used to remove smoke, in mechanical smoke extraction systems.

4 Requirements

4.1 Test device 4.1.1 High temperature-resistant test furnace This standard stipulates that the smoke and heat exhaust ventilator shall meet the requirements of 4.3 and 4.4, AND the high temperature-resistant test shall be carried out on the specified high temperature-resistant test furnace. The high temperature-resistant test furnace shall be able to control the airflow temperature, through the smoke and heat exhaust ventilator, so that it can keep constant, at any set value, within the range of 150 °C ~ 600 °C (allowable deviation ± 15 °C); meanwhile it can ensure that the temperature in the furnace, within 2 min after ignition, can rise to the selected standard temperature. The high temperature-resistant test furnace shall have a large enough space; its size shall not be less than 3000 mm × 3000 mm × 4500 mm. It shall be possible to test the aerodynamic performance of the smoke and heat exhaust ventilator, in a wind tunnel of specified size (see Figure 1), under high temperature conditions. Note: For the smoke and heat exhaust ventilator, which has a machine number of greater than No.18, refer to Figure 4 and Figure 5 for the high temperature-resistant test device and installation method. 4.1.2 Temperature measurement and control system The airflow temperature on the fire-facing surface of the smoke and heat exhaust ventilator is measured, by a K-type armored thermocouple, which has a diameter of Φ0.75 mm ~ Φ2.30 mm. The length of the hot end, which protrudes from the stainless steel casing or porcelain casing, shall not be less than 25 mm; the number of thermocouples shall not be less than 6. The thermocouples are evenly distributed on the plane, which is 100 mm away from the air inlet of the smoke and heat exhaust ventilator; the measuring end is 100 mm away from the pipe wall. The average value of the temperature, which is measured by the thermocouples, is the test temperature. The standard test temperature can be preset within the range of 150 °C ~ 600 °C. The time interval, for recording the test temperature values, shall not exceed 1 min. 4.1.3 In-furnace pressure measurement system measurement device, of the smoke and heat exhaust ventilator, is as shown in Figure 1 ~ Figure 3. 4.3.2 Fix the collector, the electric air volume control valve, the fan aerodynamic performance test pipe (standardized air duct), the smoke and heat exhaust ventilator and the rear connecting pipe of the smoke and heat exhaust ventilator, on the outside of the high temperature-resistant test furnace. The outlet and inlet of the furnace are communicated with the furnace, so as to form a heat flow cycle, between the smoke and heat exhaust ventilator and the high temperature-resistant test furnace. 4.3.3 The front and rear connecting pipes of the smoke and heat exhaust ventilator shall be made of steel plates, which have a thickness of not less than 4 mm. The size and shape of the standardized air duct shall meet the requirements of GB/T 1236-2000. All air ducts are connected by flanges. In order to prevent air leakage at the connections, sealing materials shall be used to block the flanges. The air duct shall not leak, at the pressure outlet and thermocouple on the standardized air duct. 4.3.4 There shall be no obstacles, within 3 m from the axis of the air duct inlet. The distance, from the outlet of the smoke and heat exhaust ventilator to the obstacles, shall not be less than 3 m. 4.4 High temperature-resistant test requirements for smoke and heat exhaust ventilators 4.4.1 The smoke and heat exhaust ventilator, which is used in the tunnel area, shall run continuously for 60 minutes, when the airflow is not lower than 250 °C, without abnormal phenomenon. 4.4.2 The smoke and heat exhaust ventilator, which is used in subway tunnels, shall run continuously for 60 minutes, when the airflow is not lower than 150 °C, without abnormal phenomenon. 4.4.3 The smoke and heat exhaust ventilators, which are used in other buildings, shall run continuously for 30 minutes, when the airflow is not lower than 280 °C, without abnormal phenomenon. the smoke fan. 5.2 Check the air tightness of the air duct and the smoothness of the pressure outlet. 5.3 Shutdown the smoke and heat exhaust ventilator. Wait for the high temperature- resistant test. 5.4 Ignite the high temperature-resistant test furnace. At the same time, start the smoke and heat exhaust ventilator, to make it run. Control the furnace temperature, so that the temperature of the airflow, which passes through the smoke and heat exhaust ventilator, reaches the standard test temperature, within 2 minutes. Keep the smoke and heat exhaust ventilator run continuously for 30 min, at this temperature, without abnormal phenomena (for smoke and heat exhaust ventilator in tunnels, subway sections and other places, it shall run continuously, under the corresponding standard test temperature for the specified time, without abnormal phenomenon). 5.5 The standard test temperature shall be selected, according to the high temperature- resistant performance of the smoke and heat exhaust ventilator, which is proposed by the manufacturer. Meanwhile it shall meet the following requirements: a) For the smoke and heat exhaust ventilator, which is used in the tunnel segments, the selected temperature shall not be lower than 250 °C; b) For smoke and heat exhaust ventilators, which are used in subway tunnels, the selected temperature shall not be lower than 150 °C; c) For other smoke and heat exhaust ventilators, which are used in buildings, the selected temperature shall not be lower than 280 °C. 5.6 During the test, if the smoke and heat exhaust ventilator does not conform to the judgment criteria, which is specified in Chapter 7, the test can be terminated. 5.7 During the high temperature-resistant test of the smoke and heat exhaust ventilator, adjust the open-close state of the blades of the electric control valve (simulating paper patch), to control the air volume, which passes through the smoke and heat exhaust ventilator. Measure the aerodynamic performance of the smoke and heat exhaust ventilator, under the high temperature-resistant state. According to the method, which is specified in GB/T 1236-2000, measure the flow rate, pressure, total pressure efficiency of the smoke and heat exhaust ventilator. Measure the vibration of the smoke and heat exhaust ventilator, according to the method, which is specified in JB/T 8689- 1998. Note: The test results of the aerodynamic performance of the smoke and heat exhaust ventilator, during the high temperature-resistant test, are not used as the basis for judgment, BUT only for reference for actual expansion. 5.8 For the smoke and heat exhaust ventilator, which has a machine number of more ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GA 211-2009 be delivered?

Answer: The full copy PDF of English version of GA 211-2009 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GA 211-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GA 211-2009_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GA 211-2009 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GA 211-2009?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GA 211-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GA 211-2009?

A step-by-step guide to download PDF of GA 211-2009_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GA 211-2009".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9