Firefighter protective auxiliary equipment. Goggles for firefighters
| Obsolete |
GA 1273-2015
|
PDF similar to GA 1273-2015
Standard similar to GA 1273-2015 GA 10 GA 602 GB 21976.7
Basic data | Standard ID | GA 1273-2015 (GA1273-2015) | | Description (Translated English) | Firefighter protective auxiliary equipment. Goggles for firefighters | | Sector / Industry | Public Security (Police) Industry Standard | | Classification of Chinese Standard | C85 | | Classification of International Standard | 13.220.10 | | Word Count Estimation | 16,179 | | Date of Issue | 2015-10-12 | | Date of Implementation | 2016-02-01 | | Quoted Standard | GB/T 191; GB/T 2410-2008; GB/T 9969; GB/T 10000-1988; GB/T 14866-2006; GB/T 16422.3-2014 | | Regulation (derived from) | Industry standard filing notice 2016 No. 5 (total 197) | | Issuing agency(ies) | Ministry of Public Security | | Summary | This standard specifies the terms and definitions, type, basic requirements, special requirements, test methods, inspection rules, marking, packaging, transport and storage of firefighter goggles. This standard is applicable to goggles used by firefighters during fire fighting and rescue operations; they do not apply to goggles used in arc, laser and nuclear radiation environments. |
GA 1273-2015: Firefighter protective auxiliary equipment. Goggles for firefighters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Firefighter protective auxiliary equipment.Goggles for firefighters
ICS 13.220.10
C85
People's Republic of China Public Security Industry Standards
Auxiliary firefighters Protective equipment for firefighters goggles
Issued on. 2015-10-12
2016-02-01 implementation
People's Republic of China Ministry of Public Security
Foreword
The standard 5.2 to 5.12, chapter 8 and 9.1 are mandatory, the rest are recommended.
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard was proposed by the Ministry of Public Security Fire Department.
This standard by the National Standardization Technical Committee firefighters Fire Protection Equipment Technical Committee (SAC/TC113/SC12) centralized.
This standard was drafted. Shanghai Fire Research Institute of Ministry of Public Security.
The main drafters of this standard. Ma Weiguang, CONTRIBUTIONS, Rui Kun, Wang Yi, Yang Haitao, Zhang Lei, Zhu Xiang.
Auxiliary firefighters Protective equipment for firefighters goggles
1 Scope
This standard specifies the terms and definitions firefighters goggles, model, basic requirements, special requirements, test methods, inspection rules, marking,
Packaging, transport and storage.
This standard applies to the fire fighting and rescue operations when firefighters wearing goggles; does not apply to electric arc, laser and nuclear radiation environment of
Goggles.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191 Packaging - Pictorial signs
Determination of GB/T 2410-2008 transparent plastic light transmittance and haze
GB/T 9969 General Instructions industrial products
GB/T 10000-1988 Chinese adult body size
GB/T 14866-2006 personal eye protectors technical requirements
GB/T 16422.3-2014 Plastics - Methods of exposure to laboratory light sources - Part 3. Fluorescent UV lamps
3 Terms and Definitions
GB/T 14866-2006 define the following terms and definitions apply to this document.
3.1
Firefighters goggles gogglesforfirefighter
Firefighters fire and rescue mission in the implementation of the wearer, so that the eyes from smoke, chemicals, metal sparks flying debris and dust damage
A protective glass.
3.2
Reference point referencepoint
Firefighters on the lens selected reference measurement point goggles performance testing.
4 Model
Model preparation firefighters goggles shall meet the following requirements.
|