Path: Home > MISC > Page27 > CJ/T 132-2014 || Home > Standard_List > MISC > Page27 > CJ/T 132-2014
Price & DeliveryUS$709.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. CJ/T 132-2014: Automatic suction solenoid valves for gas burning appliances Status: Valid
CJ/T 132: Evolution and historical versions
| Std ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status |
| CJ/T 132-2014 | English | 709 |
Add to Cart
|
5 days [Need to translate]
|
Automatic suction solenoid valves for gas burning appliances
| Valid |
| CJ/T 132-2001 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Automatic gas values for household gas appliances
| Obsolete |
Standard similar to CJ/T 132-2014 GB/T 13611 | CJ/T 393 | GB/T 16411 | CJ/T 513 | CJ/T 199 | CJJ 132 |
Basic data | Standard ID | CJ/T 132-2014 (CJ/T132-2014) | | Description (Translated English) | Automatic suction solenoid valves for gas burning appliances | | Sector / Industry | Urban Construction Industry Standard (Recommended) | | Classification of Chinese Standard | P45 | | Classification of International Standard | 91.140 | | Word Count Estimation | 27,253 | | Date of Issue | 4/9/2014 | | Date of Implementation | 8/1/2014 | | Older Standard (superseded by this standard) | CJ/T 132-2001 | | Quoted Standard | GB/T 191; GB/T 1690-2010; GB/T 3091; GB/T 7306.1; GB/T 7306.2; GB/T 7307; GB/T 9114; GB/T 9144; GB/T 12716; GB/T 13611; GB 14536.1-2008; GB/T 15530.1; GB/T 15530.2; GB/T 15530.3; GB/T 15530.4; GB/T 15530.5; GB/T 15530.6; GB/T 15530.7; GB/T 15530.8; GB/T 1 | | Regulation (derived from) | Ministry of Housing and Urban-Rural Development Bulletin No. 377; industry standards filing Notice 2014 No. 6 (No. 174 overall) | | Issuing agency(ies) | Ministry of Housing and Urban-Rural Development of the People's Republic of China | | Summary | This Standard specifies the domestic gas burning appliances with self-priming valve (hereinafter referred to as self-priming valve) terms and definitions, classification and grouping, structures and materials, requirements, test methods, marking, installa |
CJ/T 132-2014: Automatic suction solenoid valves for gas burning appliances---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Automatic suction solenoid valves for gas burning appliances
ICS 91.140
P45
People's Republic of China urban construction industry standards
Replace CJ/T 132-2001
Household gas burner with self-priming valve
2014-04-09 released
2014-08-01 implementation
Ministry of Housing and Urban-Rural Development, People's Republic of China released
Directory
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 classification and grouping 1
5 Structure and materials 2
6 Requirements 5
7 Test Methods 9
8 Identification, installation and operating instructions 16
Inspection rules 17
10 Packaging, transportation and storage 18
Appendix A (Informative) Air tightness test --- volumetric method 20
Appendix B (informative) This standard supports the basic requirements of GB 16914-2012 The corresponding table 22
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces CJ/T 132-2001 "household gas burner with automatic gas valve."
This standard is the revision of CJ/T 132-2001 "household gas burner with automatic gas valve", compared with the CJ/T 132-2001
To technical changes are as follows.
--- This standard is mainly the continuation of the self-priming valve content;
--- Added terms and definitions (see Chapter 3);
--- Increased classification (see Chapter 4);
--- Increased rated flow (see 6.3.3);
--- Increased oil resistance (see 6.3.4.3);
--- Increased logo durability (see 6.3.4.4);
--- Increased scratch resistance (see 6.3.4.5);
--- Increased resistance to moisture (see 6.3.4.6);
--- Increased air tightness (see 6.3.8);
--- Modify the structure and material requirements (see Chapter 5,.2001 edition Chapter 4, Chapter 5);
--- Modify the air tightness (see 6.3.1,.2001 edition Chapter 3);
--- Modify the current and voltage when the valve is opened and closed (see 6.3.3, 6.3.3, 6.3.3,.2001 Chapter 3);
--- Modify the mechanical durability (see 6.3.14,.2001 edition Chapter 3);
--- Modify the torque strength (see 6.3.2.2,.2001 version Chapter 3);
--- Modify the diaphragm, gaskets, lining gas-resistant gas resistance, gas-proof sealing material properties (see 6.3.4.2,.2001 version Chapter 3);
--- Remove the negative pressure strength, coil temperature rise, moisture resistance, high temperature and low temperature performance, voltage strength, resistance to thermal shock,
Thick grease (see Chapter 3 of the.2001 edition).
This standard is consistent with GB 16914-2012 "gas burning appliances safety conditions", given in Appendix B of this standard branch
GB 16914-2012 with the basic requirements of the provisions of the corresponding table.
This standard proposed by the Ministry of Housing and Urban Standard and Design Institute.
This standard by the Ministry of Housing and Urban Gas Standardization Technical Committee centralized.
This standard was drafted. China Municipal Engineering North China Design and Research Institute, Zhejiang Overseas Chinese Industrial Co., Ltd., Qingdao Economic and Technological Development Zone
Haier Water Heater Co., Ltd., Guangdong Macro Gas Co., Ltd., Zhejiang Xintao Electronic Machinery Co., Ltd., the quality of gas appliances
Quantity Supervision and Inspection Center.
The main drafters of this standard. Pan Cuijing, Zhang Xi, Liu Yun, Zhao Rouping, He Minghui, Wei Ru.
This standard replaces the standards previously issued as follows.
--- CJ/T 132-2001.
Household gas burner with self-priming valve
1 Scope
This standard specifies the terms and definitions, classification and grouping of household gas burner self-priming valve (hereinafter referred to as self-priming valve), structure and material
Materials, requirements, test methods, marking, installation and operating instructions, inspection rules, packaging, transport and storage.
This standard applies to the maximum working pressure is not more than 10kPa, nominal size is not greater than DN32, the working voltage is not greater than DC6V, only
Battery-driven, using self-priming valve for urban gas appliances specified in GB/T 13611.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 191 Packaging - Pictorial signs
Test method for fluid resistance of vulcanized rubber or thermoplastic rubber GB/T 1690-2010
GB/T 3091 low pressure fluid delivery welded steel pipe
GB/T 7306 (all parts) 55 ° sealing pipe thread
GB/T 7307 55 ° non-sealed pipe thread
GB/T 9114 necked steel pipe flanges
GB/T 9144 ordinary thread priority series
GB/T 12716 60 ° sealing pipe thread
GB/T 13611 urban gas classification and basic characteristics
Automatic electrical controls for household and similar use - Part 1. Generic requirements
GB/T 15530 (all parts) copper alloy flange
Household gas appliances GB/T 16411-2008 General test methods
GB/T 17241 (all parts) cast iron pipe flange
Domestic gas burning appliances conformity assessment procedures and inspection rules
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Self-priming valve automaticssosooidoid
Only battery-driven and operating voltage is not greater than DC6V, can automatically open when the power supply, power off automatically shut down when the solenoid valve.
3.2
Air tight sealingforce
The force applied to the valve seat when the closure element is in the closed position is independent of the force generated by the gas pressure.
4 classification and grouping
4.1 Classification
According to the air tightness requirement of 6.3.8, the self-priming valve is divided into A grade, B grade and C grade.

Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of CJ/T 132-2014_English be delivered?Answer: Upon your order, we will start to translate CJ/T 132-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of CJ/T 132-2014_English with my colleagues?Answer: Yes. The purchased PDF of CJ/T 132-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version CJ/T 132-2014?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version CJ/T 132-2014 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|