HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (6 Oct 2024)

GB/T 6368-2008 PDF in English


GB/T 6368-2008 (GB/T6368-2008, GBT 6368-2008, GBT6368-2008)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 6368-2008English70 Add to Cart 0-9 seconds. Auto-delivery. Surface active agents -- Determination of pH of aqueous solution -- Potentiometric method Valid
GB/T 6368-1993English199 Add to Cart 2 days Surface active agents. Determination of pH of aqueous solutions. Potentiometric method Obsolete
Standards related to (historical): GB/T 6368-2008
PDF Preview

GB/T 6368-2008: PDF in English (GBT 6368-2008)

GB/T 6368-2008 GB ICS 71.100.40 G 72 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA GB/T 6368-2008 / ISO 4316.1977 Replacing GB/T 6368-1993 Surface active agents - Determination of pH of aqueous solution - Potentiometric method (ISO 4316.1977, IDT) ISSUED ON. APRIL 1, 2008 IMPLEMENTED ON. OCTOBER 1, 2009 Jointly issued by. General Administration of Quality Supervision, Inspection and Quarantine (AQSIQ); Standardization Administration Committee (SAC) of the People’s Republic of China. GB/T 17795-2008 Table of Contents Foreword ... 3 1 Scope ... 4 2 Normative References ... 4 3 Principle ... 4 4 Reagents ... 4 5 Instruments and equipment ... 4 6 Measurement ... 5 7 Test report ... 5 GB/T 17795-2008 Foreword This standard replaces GB/T 6368-1993 Surface active agents - Determination of pH of aqueous solutions - Potentiometric method. This standard equivalently adopts ISO 4316.1977 Surface active agents - Determination of pH of aqueous solutions - Potentiometric method. The main differences between this standard and the previous version. - Add the Preface; - Increase the degree of adoption; - Increase the quantity of measurement samples, so as to be consistent with international standards; - Add Chapter test report. This standard was proposed by China Petroleum and Chemical Industry Association. This standard shall be under the jurisdiction of Chemical Industry Surfactant Standardization Technical Committee. Drafting organizations of this standard. Shanghai Dye Institute Ltd., and Zhejiang Real Chemical Group. Drafters of this standard. Zhuang Yongbin, Huang Weiqing, Wang Weisong, and Meng Zhaoping. This standard was first-time released in 1986, and it was first-time revised in 1993. GB/T 17795-2008 Surface active agents - Determination of pH of aqueous solution - Potentiometric method 1 Scope This standard specifies the method of adopting potentiometric method to determine pH of aqueous solution of surface active agents. This standard applies to the determination of pH of aqueous solution of surface active agents. 2 Normative References The following standards contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, the subsequent amendments (excluding corrigendum) or revisions of these publications do not apply. However, the parties who enter into agreement based on this standard are encouraged to investigate the possibility of applying the latest editions of the standards. For undated references, the latest editions of the normative document referred to apply. GB/T 603-2002 Chemical reagent – Preparations of reagent solution for use in test GB/T 6682-1992 Water for analytical laboratory use - Specification and test methods 3 Principle Measure the electrode potential difference immersed in an aqueous solution of surface active agent, expressed in pH value. 4 Reagents 4.1 Distilled water. Without carbon dioxide. It shall comply Grade 3 water as specified in GB/T 6682-1992. Prepare it according to provision 4.1.1.1 in GB/T 603-2002. 4.2 Standard buffer solution. Select 2 solutions from the common standard solutions to calibrate the potentiometer. Their pH value shall be as near as possible to the expected pH value of the sample solution. In which, the difference BETWEEN 1 of the standard solution AND the expected value must not be greater than 1 pH unit. 5 Instruments and equipment 5.1 pH meter. Minimum scale of 0.1 pH unit. 5.2 Glass electrode. 5.3 Reference electrode. Calomel / potassium chloride saturated solution type. 5.4 Composite electrode. It is used to replace the glass electrode and reference electrode. GB/T 17795-2008 ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.