HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (16 Mar 2025)

GB/T 38014-2019 PDF English


Search result: GB/T 38014-2019 English: PDF (GB/T38014-2019)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 38014-2019English150 Add to Cart 0-9 seconds. Auto-delivery. Textiles - Protective nonwoven fabrics for surgical use Valid


PDF Preview: GB/T 38014-2019


GB/T 38014-2019: PDF in English (GBT 38014-2019)

GB/T 38014-2019 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 59.080.30 W 59 Textiles - Protective nonwoven fabrics for surgical use ISSUED ON: AUGUST 30, 2019 IMPLEMENTED ON: MARCH 01, 2020 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Terms and definitions ... 5  4 Product classification ... 6  5 Technical requirements ... 6  6 Test methods ... 8  7 Inspection rules ... 10  8 Packaging, marking, storage and transportation ... 11  Textiles - Protective nonwoven fabrics for surgical use 1 Scope This Standard specifies the terms and definitions, product classification, technical requirements, test methods, inspection rules, packaging, marking, storage and transportation of protective nonwoven fabrics for surgical use. This Standard applies to single-layer non-woven fabrics, composite non-woven fabrics, film-coated non-woven fabrics that are used in surgical gowns, clean air suits and surgical drapes. 2 Normative references The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document. GB/T 250, Textiles - Tests for colour fastness - Grey scale for assessing change in colour GB/T 3920, Textiles - Tests for colour fastness - Colour fastness to rubbing GB/T 4666, Textiles - Fabrics - Determination of width and length GB/T 7742.1, Textiles - Bursting properties of fabrics - Part 1: Hydraulic method for determination of bursting strength and bursting distension GB/T 12703.4, Textile - Evaluation for electrostatic properties - Part 4: Resistivity GB/T 12704.1-2009, Textiles - Test method for water-vapour transmission of fabrics - Part 1: Desiccant method GB 15979, Hygienic standard for disposable sanitary products GB 18401-2010, National general safety technical code for textile products GB/T 24120, Textiles - Determination of resistance to water/alcohol solution GB/T 24218.1, Textiles - Test methods for nonwovens - Part 1: Determination of mass per unit area GB/T 24218.3, Textiles - Test methods for nonwovens - Part 3: Determination of tensile strength and elongation (strip method) GB/T 24218.10, Textiles - Test methods for nonwovens - Part 10: Lint and other particles generation in the dry state GB/T 24218.16, Textiles - Test methods for nonwovens - Part 16: Determination of resistance to penetration by water (hydrostatic pressure) YY/T 0506.2-2016, Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment - Part 2: Performance requirements and test methods YY/T 0506.5, Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment - Part 5: Test method for resistance to dry microbial penetration YY/T 0506.6, Surgical drapes, gowns and clean air suits, used as medical devices, for patients, clinical staff and equipment - Part 6: Test method to determine the resistance to wet bacterial penetration YY/T 0506.7, Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment - Part 7: Test methods for determination of cleanliness- microbial 3 Terms and definitions The following terms and definitions are applicable to this document. 3.1 Standard performance surgical gowns (drapes) Surgical gowns (drapes) that meets the minimum performance requirements during traumatic surgery. 3.2 High performance surgical gowns (drapes) Surgical gowns (drapes) that meet the stricter performance requirements during traumatic surgery. Note: During surgery, those who are expected to be over-exposed to fluids, mechanical stress, or longer surgical operation should use high performance surgical gowns (drapes). 6.4 The determination of cleanliness (particulate matter) shall be carried out in accordance with GB/T 24218.10; the calculation shall be carried out in accordance with A.3 of YY/T 0506.2-2016. 6.5 The determination of lint shall be carried out in accordance with GB/T 24218.10. 6.6 The determination of hydrostatic pressure shall be carried out in accordance with GB/T 24218.16; the rate of rise of water pressure shall be (10 ± 0.5) cmH2O/min. 6.7 The determination of bursting strength shall be carried out in accordance with GB/T 7742.1. 6.8 The determination of breaking force shall be carried out in accordance with GB/T 24218.3. 6.9 The determination of resistance to alcohol penetration shall be carried out in accordance with GB/T 24120. 6.10 The determination of water-vapor transmission shall be carried out in accordance with the condition a) in Chapter 7 of GB/T 12704.1-2009. 6.11 The determination of color fastness to rubbing shall be carried out in accordance with GB/T 3920. 6.12 The determination of odor shall be carried out in accordance with 6.7 in GB 18401-2010. 6.13 The determination of cleanliness-microbial shall be carried out in accordance with YY/T 0506.7. 6.14 The determination of coliform bacteria and pathogenic pyogenic bacteria shall be carried out in accordance with GB 15979. 6.15 The determination of electrostatic properties (surface resistivity) shall be carried out in accordance with GB/T 12703.4. 6.16 The chromatic aberration is evaluated according to GB/T 250. 6.17 The fabric width is determined according to GB/T 4666. 6.18 The inspection of appearance defects is mainly based on the front of the product. The inspection shall be carried out on a horizontal inspection table; it shall use normal daylight northern light or fluorescent lighting; the table illumination is not less than 750 lx; the distance between the eyes and the table is about 60 cm. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.