HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (14 Sep 2024)

GB/T 36102-2018 PDF in English


GB/T 36102-2018 (GB/T36102-2018, GBT 36102-2018, GBT36102-2018)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 36102-2018English90 Add to Cart 0-9 seconds. Auto-delivery. Tin-coated copper-clad steel wire for electronic products Valid
Standards related to: GB/T 36102-2018
PDF Preview

GB/T 36102-2018: PDF in English (GBT 36102-2018)

GB/T 36102-2018 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.060.10 K 11 Tin-coated copper-clad steel wire for electronic products ISSUED ON. MARCH 15, 2018 IMPLEMENTED ON. OCTOBER 1, 2018 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the PRC; Standardization Administration of the PRC. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Classification and type ... 5  4 Requirements ... 5  5 Test methods ... 8  6 Inspection rules ... 10  7 Packaging, product marking, transport, and storage ... 11  8 Content of order contract ... 12  Tin-coated copper-clad steel wire for electronic products 1 Scope This Standard specifies the classification and type, requirements, test methods, inspection rules, packaging, product marking, transport, and storage, etc. of tin- coated copper-clad steel wire for electronic products. This Standard applies to the tin-coated copper-clad steel wire for electronic products which takes copper-clad steel wire as base wire. 2 Normative references The following documents are indispensable for the application of this document. For the dated references, only the versions with the dates indicated are applicable to this document. For the undated references, the latest version (including all the amendments) are applicable to this document. GB/T 728-2010 Ingot tin GB/T 2423.32-2008 Environmental testing for electric and electronic products - Part 2. Test methods - Test Ta. Solderability test by the wetting balance method GB/T 3048.2-2007 Test methods for electrical properties of electric cables and wires - Part 2. Test of electrical resistivity of metallic materials GB/T 4909.2-2009 Test methods for bare wires - Part 2. Measurement of dimensions GB/T 4909.3-2009 Test methods for bare wires - Part 3. Tensile test GB/T 4909.5-2009 Test methods for bare wires - Part 5. Bend test - Reverse bend test GB/T 4909.9-2009 Test methods for bare wires - Part 9. Test for continuity of coating - Sodium polysulfide solution method GB/T 4909.11-2009 Test methods for bare wires - Part 11. Test for adherence of coating GB/T 6462-2005 Metallic and oxide coatings - Measurement of coating is less than the specified value and the breaking point appears within 25 mm from the chuck of tester or the gauge length of extensometer, the data is invalid; and the test shall be repeated. 5.5 Reverse bend The number of reverse bend of tin-coated copper-clad steel wire shall be tested in accordance with the provisions of GB/T 4909.5-2009. 5.6 Coating thickness The coating thickness of tin-coated copper-clad steel wire shall be measured in accordance with the provisions of GB/T 6462-2005. Other measuring methods agreed upon by both supply and demand sides can also be used. 5.7 Continuity of coating The continuity of coating of tin-coated copper-clad steel wire shall be tested in accordance with the provisions of Procedure a) in 5.5 of GB/T 4909.9-2009. The test piece shall be subjected to two immersion cycles. 5.8 Adherence of coating The adherence of coating of tin-coated copper-clad steel wire shall be tested in accordance with the provisions of GB/T 4909.11-2009. The test piece shall be wound on a test rod which does not exceed 4 times the nominal diameter of the wire. The test piece after being wound is subjected to one-cycle immersion test. 5.9 Solderability The normal solderability of tin-coated copper-clad steel wire shall be tested in accordance with the provisions of GB/T 2423.32-2008 and the following detailed rules. a) Test piece preparation. On each coil (shaft) of sample drawn in the specified number, CUT off 2 test pieces with a length of about 30 mm. The test piece shall not be touched by hand or contaminated, and before the test, shall not be cleaned. b) Test conditions. The solder is Sn96.5Ag3.0Cu0.5. The soldering flux is prepared with 25% of rosin and 75% of ethyl alcohol. The test temperature is (245±3)°C. c) Test parameters. The immersing depth is 3 mm. The immersing speed is 20 mm/s. The immersing duration is 5 s. d) Test result. On the automatically-recorded wetting curve, TAKE the than 3 coils (shafts). When the batch is large, it shall not be more than 10 coils (shafts). The test piece shall be cut off from each sample unit (coil or shaft). 6.4 Determination rules If all inspections are qualified, the inspection batch shall be qualified. When there is an unqualified item, it shall take double the number of samples for the second inspection of the unqualified item; if there is still nonconformity, the batch of products shall be judged as unqualified. 7 Packaging, product marking, transport, and storage 7.1 Packaging Tin-coated copper-clad steel wire shall be evenly and neatly wound around the wire coil (shaft). The wire end shall be firmly fixed. Proper distance shall be maintained between the outermost wire turn and the edge of side plate of wire coil. Each coil (shaft) of wire shall be wrapped with Kraft paper and then packaged in a plastic bag containing desiccant, and then loaded into a barrel (box) lined with moisture-proof paper. 7.2 Product marking Each coil (shaft) of tin-coated copper-clad steel wire products shall be accompanied by a label, which indicates. a) Name of manufacturing enterprise (with bar code attached); b) Type and specification; c) Gross weight and net weight (kg); d) Production date (year and month, or batch number); e) This Standard’s number. 7.3 Transport The product, during transport, shall be protected from wet oxidation and corrosion. 7.4 Storage The product shall be stored in a dry, ventilated, non-corrosive media and hazardous gas warehouse. The storage time shall not exceed half a year. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.