GB/T 32115-2015 PDF English                    
       
  US$165.00 · In stock · Download in 9 secondsGB/T 32115-2015: Determination of ethylene glycol and diethylene glycol in oral care products Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See  step-by-step procedureStatus: Valid    
    
  
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status | 
		 
			| GB/T 32115-2015 | English | 165 | 
   Add to Cart
    | 
                    0-9 seconds. Auto-delivery
                 | 
                    Determination of ethylene glycol and diethylene glycol in oral care products
                 | Valid | 
		 
	 
 
      
    
	  
       Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: GB/T 32115-2015       
    
    
     
    
    GB/T 32115-2015: Determination of ethylene glycol and diethylene glycol in oral care products---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT32115-2015  
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 71.100.40
Y 43
Determination of Ethylene Glycol and Diethylene Glycol in
Oral Care Products
ISSUED ON: OCTOBER 13, 2015
IMPLEMENTED ON: MAY 1, 2016
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine of the People’s Republic of China;
Standardization Administration of the People’s Republic of China.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative References ... 4
3 Principle ... 4
4 Reagents and Materials ... 4
5 Instruments and Equipment ... 5
6 Analytical Procedures ... 5
7 Result Calculation ... 7
8 Detection Limits ... 8
9 Allowable Difference ... 8
Appendix A (informative) Gas Chromatogram of Standard Samples ... 9
Appendix B (informative) Confirmatory Test ... 10
Determination of Ethylene Glycol and Diethylene Glycol in
Oral Care Products
1 Scope
This Standard specifies the principle, reagents and materials, instruments and equipment,
analytical procedures, result calculation, detection limits and allowable difference for the
determination of ethylene glycol and diethylene glycol in oral care products.
This Standard is applicable to the determination of ethylene glycol and diethylene glycol
contents in oral care products.
In this Standard, the detection limits of ethylene glycol and diethylene glycol are both 20 mg/kg.
2 Normative References
The following documents are indispensable to the application of this document. In terms of
references with a specified date, only versions with a specified date are applicable to this
document. In terms of references without a specified date, the latest version (including all the
modifications) is applicable to this document.
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods
3 Principle
Ethylene glycol and diethylene glycol in oral care products are extracted with methanol by
ultrasonic method, filtered, then, separated and determined by gas chromatograph-hydrogen
flame ionization detector, qualitatively determined by retention time, quantitatively determined
by external standard method, and confirmed by chromatography-mass spectrometry.
4 Reagents and Materials
4.1 Unless otherwise specified, all reagents used are analytically pure, and water is Grade-1
water as specified in GB/T 6682.
4.2 Methanol: chromatographically pure.
4.3 Sodium chloride.
4.4 Ethylene glycol standard sample: purity  99%. For relevant information, see Table 1.
4.5 Diethylene glycol standard sample: purity  99%. For relevant information, see Table 1.
Weigh-take 2 g (accurate to 0.01 g) of sample into a 50 mL graduated tube with a stopper, add
20.0 mL of methanol (4.2), add 2.0 g of sodium chloride (4.3), and perform vortex mixing for
1 minute. Then, perform ultrasonic extraction for 20 minutes, let it stand, filter the supernatant
through the filter membrane (4.8) and reserve it for testing.
6.1.3 Powder
Weigh-take 2 g (accurate to 0.01 g) of sample into a 50 mL graduated tube with a stopper, add
20.0 mL of methanol (4.2), and perform vortex mixing for 1 minute. Then, perform ultrasonic
extraction for 20 minutes, let it stand, filter the supernatant through the filter membrane (4.8)
and reserve it for testing.
6.2 Determination
6.2.1 Reference conditions of gas chromatography
6.2.1.1 Chromatographic column: HP-INNOWAX quartz capillary chromatographic column,
30 m  0.25 mm (inner diameter)  0.25 m, or one with equivalent performance.
6.2.1.2 Carrier gas: high-purity nitrogen, purity > 99.99%.
6.2.1.3 Flow rate: 1.0 mL/min, constant-flow mode.
6.2.1.4 Use programmed temperature rise: the initial column temperature is 40 C, maintain it
for 1 minute, then, at a rate of 10 C/min, raise the temperature to 150 C and maintain it for 10
minutes, then, at a rate of 30 C/min, raise the temperature to 250 C and maintain it for 5
minutes.
6.2.1.5 Inlet temperature: 240 C.
6.2.1.6 Detector temperature: 250 C.
6.2.1.7 Sample injection mode: split injection, with a split ratio of 10 : 1.
6.2.2 Drawing of standard working curve
Determine a series of ethylene glycol and diethylene glycol mixed standard working solutions
(4.7) with a concentration of 10.0 g/mL, 50.0 g/mL, 100.0 g/mL, 200.0 g/mL and 500.0
g/mL in accordance with the reference conditions of gas chromatography (6.2.1). By taking
the peak area as the y-coordinate and the concentration as the x-coordinate, draw the standard
working curve.
For the gas chromatogram of standard samples of ethylene glycol and diethylene glycol, please
refer to Figure A.1 of Appendix A.
6.2.3 Quantitative analysis
Determine the sample solution obtained through sample preparation (6.1) in accordance with
the reference conditions of gas chromatography (6.2.1) and record the retention time and peak
area of the chromatographic peak. The corresponding concentrations of ethylene glycol and
diethylene glycol can be calculated through the peak area of the chromatographic peak from
the standard working curve. The response values of ethylene glycol and diethylene glycol in
the sample to be determined shall be within the linear range of the standard working curve. If
they exceed the linear range, then, sample injection and analysis shall be performed after
dilution.
6.2.4 Qualitative confirmation
For samples with positive results during the determination process, it is recommended to
confirm with gas chromatography-mass spectrometry, see Appendix B.
6.3 Blank Test
Except that the sample is not weighed, in accordance with the sample preparation (6.1) steps
and determination (6.2) conditions, carry out the blank test.
6.4 Parallel Test
In accordance with the sample preparation (6.1) steps and determination (6.2) conditions,
conduct parallel test and determination on the same sample.
7 Result Calculation
The ethylene glycol and diethylene glycol contents (mg/kg) in oral care products shall be
calculated in accordance with Formula (1):
Where,
X---the ethylene glycol and diethylene glycol contents in oral care products, expressed in
(mg/kg);
c---the ethylene glycol and diethylene glycol concentrations in the sample determination
solution, expressed in (g/mL);
V---the final constant volume of the sample solution, expressed in (mL);
k---the dilution factor;
m---the mass of the sample, expressed in (g).
NOTE: the blank value must be subtracted from the calculation result. The determination result is
expressed as the arithmetic mean of parallel determinations and rounded to the nearest
Appendix B
(informative)
Confirmatory Test
B.1 Reference Conditions of Gas Chromatography
Chromatographic column: HP-INNOWAX quartz capillary chromatographic column, 30 m 
0.25 mm (inner diameter)  0.25 m, or one with equivalent performance.
Carrier gas: high-purity helium, purity > 99.99%.
Flow rate: 1.0 mL/min, constant-flow mode.
Use programmed temperature rise: the initial column temperature is 40 C, maintain it for 1
minute, then, at a rate of 10 C/min, raise the temperature to 150 C and maintain it for 10
minutes, then, at a rate of 30 C/min, raise the temperature to 250 C and maintain it for 5
minutes.
Inlet temperature: 240 C.
Injection volume: 1 L.
Sample injection mode: split injection.
Split ratio: 5 : 1.
Chromatography-mass spectrometry interface temperature: 250 C.
B.2 Reference Conditions of Mass Spectrometry
Ionization mode: electron impact source (EI).
Ionization energy: 70 eV.
Solvent delay: 5 min.
Determination mode: full scan mode, with a scanning range of 10 amu ~ 150 amu.
The quantitative ion, qualitative ion and ion abundance ratio are shown in Table B.1.
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.  
      
    
     
    
    Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of GB/T 32115-2015 be delivered?Answer: The full copy PDF of English version of GB/T 32115-2015 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of GB/T 32115-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32115-2015_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):  List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes.  www.ChineseStandard.us -- GB/T 32115-2015 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.  
     
    How to buy and download a true PDF of English version of GB/T 32115-2015?A step-by-step guide to download PDF of GB/T 32115-2015_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "GB/T 32115-2015". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9     
       
    
    
    
          
    
          
    
    
    
    
    
     
    
  
          |