GB/T 22594-2018 PDF in English
GB/T 22594-2018 (GB/T22594-2018, GBT 22594-2018, GBT22594-2018)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
GB/T 22594-2018 | English | 150 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Water treatment chemicals -- General rules for determination of density
| Valid |
GB/T 22594-2008 | English | 239 |
Add to Cart
|
3 days
|
Water treatment reagent -- General rules for the determination of density
| Obsolete |
Standards related to (historical): GB/T 22594-2018
PDF Preview
GB/T 22594-2018: PDF in English (GBT 22594-2018) GB/T 22594-2018
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 71.040.40
G 76
Replacing GB/T 22594-2008
Water treatment chemicals –
General rules for determination of density
ISSUED ON. JUNE 7, 2018
IMPLEMENTED ON. JANUARY 1, 2019
Issued by. State Administration for Market Regulation;
Standardization Administration Committee.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative references ... 4
3 Densitometer method ... 4
4 Density bottle method ... 5
5 U-shape vibrating tube method ... 7
Annex A (informative) Water density ... 10
Foreword
This Standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This Standard replaces GB/T 22594-2008 “Water treatment reagent - General
rules for the determination of density”. Compared with GB/T 22594-2008, in
addition to the editorial modifications, the main technical changes are as follows.
- added U-shape vibrating tube method (see Clause 5).
This Standard was proposed by China Petroleum and Chemical Industry
Federation.
This Standard shall be under the jurisdiction of Subcommittee on Water
Treatment Agent of National Technical Committee on Chemistry of
Standardization Administration of China (SAC/TC 63/SC 5).
The drafting organizations of this Standard. Zhejiang Shuizhiyin Testing Co.,
Ltd., Guangzhou Special Pressure Equipment Testing Institute, METTLER
TOLEDO Instruments (Shanghai) Co., Ltd., Henan Qingshuiyuan Technology
Co., Ltd., Shenzhen Junnuo Testing Co., Ltd., CNOOC Tianjin Chemical
Research and Design Institute Co., Ltd., Shijiazhuang Zhiyuan Environmental
Protection Technology Co., Ltd., China Petroleum & Chemical Corporation
Beijing Beihua Institute Yanshan Branch, Tianjin Zhengda Technology Co., Ltd.,
Chongqing University.
Main drafters of this Standard. Yu Minghua, Yin Zongjie, Chen Jianxia, Yang
Haixing, Peng Jiana, Bai Ying, Li Yongguang, Fan Dayong, Zhang Quan, Zheng
Huaili.
Version of standard substituted by this Standard is.
- GB/T 22594-2008.
Water treatment chemicals -
General rules for determination of density
1 Scope
This Standard specifies general methods for density determination of water
treatment chemicals.
This Standard is applicable to the density determination of water treatment
chemicals.
2 Normative references
The following referenced documents are indispensable for the application of
this document. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any
amendments) applies.
GB/T 6682, Water for analytical laboratory use - Specification and test
methods
3 Densitometer method
3.1 Method summary
The density of the liquid is read by the depth at which the densitometer is
submerged in the equilibrium state of the sample to be tested.
3.2 Equipment and instruments
3.2.1 Densitometer. the division value is 0.001 g/cm3.
3.2.2 Glass measuring cylinder. 250mL ~ 500mL.
3.2.3 Constant temperature water bath. temperature control at (20±0.1)°C.
3.3 Test steps
3.3.1 Determination of density at constant temperature (20°C). slowly inject the
sample to be tested into a clean, dry cylinder without bubbles; place the
measuring cylinder in a constant temperature water bath at (20±0.1)°C. After
Warning -- The reagent ammonium persulfate used in this method is a
strong oxidant, which is irritating and corrosive. Avoid inhalation or
contact with eyes and skin when using. If contact occurs, rinse
immediately with plenty of water. If it is serious, seek medical attention
immediately.
5.2.1 General rules
The reagents and water used in this method, unless otherwise specified, only
use analytical reagents and grade three water in accordance with GB/T 6682.
5.2.2 Ammonium persulfate solution
Weigh 0.8 g of ammonium persulfate. Dilute to 100mL with water and shake
well.
5.2.3 Standard sample
5.2.3.1 Air. air density value = 1.293 × (actual pressure/standard physical
atmospheric pressure) × (273.15/actual absolute temperature). At 20°C, an
atmospheric pressure, the air density value is 0.001205 g/cm3.
5.2.3.2 Water. grade 2 water in accordance with GB/T 6682; or standard water
sample purchased of commercially available density. At 20°C, the water density
value is 0.9982057 g/cm3. See Annex A for density values of water at different
temperatures.
5.3 Equipment and instruments
5.3.1 U-shape vibrating tube densitometer (referred to as densitometer).
accuracy is ±0.001 g/cm3; temperature accuracy is ±0.1°C.
5.4 Instrument preparation
5.4.1 Selection of washing solvent
Select volatile solvents according to the nature of the sample to be tested.
Generally, water, acetone, absolute ethanol, etc. are commonly used.
5.4.2 Cleaning U-shape tube
5.4.2.1 Clean the U-shape tube with washing solvent and dry it with clean dry
air.
5.4.2.2 When a precipitate appears in the U-shape tube, it is injected into the
U-shape tube with ammonium persulfate solution. After draining the ammonium
persulfate solution, it is washed with water, washed with a water-miscible
washing solvent, and then dried with clean dry air.
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|