HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB 12528.11-2003 PDF English

US$140.00 · In stock · Download in 9 seconds
GB 12528.11-2003: Insulated cables (wires) for railway vehicles of rated voltages up to and including 3 kV Amendment 1: Cross-linked polyolefin insulated cables (wires) for railway vehicles
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Obsolete
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB 12528.11-2003English140 Add to Cart 0-9 seconds. Auto-delivery Insulated cables (wires) for railway vehicles of rated voltages up to and including 3 kV Amendment 1: Cross-linked polyolefin insulated cables (wires) for railway vehicles Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB 12528.11-2003
      

Similar standards

GB/T 12706.1   GB/T 12706.4   GB/T 12706.3   GB/T 29631   

GB 12528.11-2003: Insulated cables (wires) for railway vehicles of rated voltages up to and including 3 kV Amendment 1: Cross-linked polyolefin insulated cables (wires) for railway vehicles



---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB12528.11-2003
GB ICS 29.060.20 K 13 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Insulated cables (wires) for railway vehicles of rated voltages up to and including 3 kV Amendment 1. Cross-linked polyolefin insulated cables (wires) for railway vehicles Issued on: JUNE 9, 2003 Implemented on: JULY 1, 2003 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Table of Contents

Foreword ... 3 1  Scope ... 4 2  Normative references ... 4 3  Operational performance ... 6 4  Model, name and specification of the product ... 6 5  Technical requirements ... 7 6  Test method ... 14 7  Inspection rules ... 15 8  Mark and packaging ... 16

Foreword

This Amendment is the supplement to GB 12528.1-1990 Insulated cables (wires) for railway vehicles of rated voltages up to and including 3 kV -- Part 1. General rules. It is used to supplement the provisions related to the cross-linked polyolefin insulated cables (wires) for railway vehicles that are not covered in GB 12528.1-1990. This Amendment shall be under the jurisdiction of the National Electric Wire Electric Cable Standardization Committee. The drafting organizations of this Amendment. Shanghai Nan Yang Electrical Appliance Co., Ltd., and Tianjin Jinshan Wire & Cable Co., Ltd. The main drafters of this Amendment. Zhang Guoping, and Zheng Guojun. Insulated cables (wires) for railway vehicles of rated voltages up to and including 3 kV Amendment 1. Cross-linked polyolefin insulated cables (wires) for railway vehicles

1  Scope

This document specifies the models, specifications, technical requirements and test methods, marks and packaging of the cross-linked polyolefin insulated cables (wires) for railway vehicles of rated voltages up to and including 3 kV. This document applies to the cables for various vehicles of rated voltages up to and including 3 kV and the electric equipment used in the power distribution system, control system and signal system of the urban railway vehicles. It is especially applicable to narrow-space and places where require low smoke, halogen-free or flame retardant. 2  Normative references The articles contained in the following documents have become part of this standard when they are quoted herein. For the dated documents so quoted, all the modifications (excluding corrections) or revisions made thereafter shall not be applicable to this Standard. For the undated documents so quoted, the latest editions shall be applicable to this standard. GB/T 2951.1 Common test methods for insulating and shielding materials of electric cables Part 1. Methods for general application Section one. Measurement of thickness and overall dimensions -- Tests for determining the mechanical properties (GB/T 2951.1-1997, idt IEC 811-1-1.1993) GB/T 2951.2 Common test methods for insulating and shielding materials of electric cables -- Part 1. Methods for general application -- Section two. Thermal ageing methods (GB/T 2951.2-1997, idt IEC 811-1-2.1985) GB/T 2951.4 Common test methods for insulating and shielding materials of electric cables Part 1. Methods for general application (GB/T 2951.4-1997, idt IEC 81-1-4.1985) GB/T 2951.5 Common test methods for insulating and shielding materials of electric cables -- Part 2. Methods specific to elastomeric compounds section one -- Ozone resistance test -- Hot set test--Mineral oil immersion test (GB/T 2951.5-1997, idt IEC 811-2-1.1986) GB/T 2951.6 Common test methods for insulating and shielding materials of electric cables Part 3. Methods specific to PVC compounds section one. Pressure test at high temperature -- Test for resistance to cracking (GB/T 2951.6-1997, idt IEC 811-3-1.1985) GB/T 3048.4 Test methods for determining electrical properties of electric cables and wire -- Measurement of D.C. resistance of conductors GB/T 3048.5 Test methods for determining electrical properties of electric cables and wires -- Determining insulation resistance-Comparison-galvanometer method GB/T 3048.8 Test methods for determining electrical properties of electric cables and wires -- A.C. voltage tests GB/T 3048.9 Test methods for determining electrical properties of electric cables and wires -- A.C. spark test of insulated cores GB/T 3956 Conductors of insulated cables (GB/T 3956-1997, idt IEC 228.1978IEC 288A.1982) GB/T 4909.2 Test methods for bare wires; Measurement of dimensions GB/T 4910 Tinned round copper wire GB 6995.1 Markings for electric cables and wires. Part 1. General requirements GB 6995.3 Markings for electric cables and wires. Part 3. Identifications of cables and wires GB 12528.1 Insulated cables (wires) for railway vehicles of rated voltages up to and including 3 kV -- General GB/T 17650 (All parts) Test on gases evolved during combustion of materials from cables (idt IEC 60754) GB/T 17651 (All parts) Measurement of smoke density of cables burning under defined conditions. Part 1. Test apparatus (idt IEC 61034) GB/T 18380.1 Tests on electric cables under fire conditions – Part 1. Test on a single vertical insulated wire or cable (GB/T 18380.1-2001, idt IEC 60332-1-1993) JB/T 8137 (All parts) Delivery drums for wires and cables TB/T 1484.1-2001 Specification for cables on board rolling stock -- Part 1. Standard wall insulation cables up to AC 3 kV NFF 63-808/5.1992 Railway rolling stock -- Halogen free, electrical conductors and cables with thin insulation and protective layers. 5  Technical requirements 5.1 Conductor 5.1.1 The conductor of the WDZ-DCYJ-125 Type cables shall comply with the provisions of the fifth kind of soft copper conductor, as specified in GB/T3956. The conductor of the WDZ-DCYJ/B-125 and WDZ-DCYJ/B-150 cables shall comply with the provisions of the second kind of stranded conductor, as specified in GB/T3956. 5.1.2 The tinned round copper wire which is in line with GB/ T4910 is used in the single conductor. The conductor structure is specified in Table 2. 5.1.3 The conductor surface shall be smooth and clean, free from oil stains, no burrs and sharp edges that may damage the insulation, no raised or fractured single line. 5.1.4 A layer of isolation layer made of suitable materials is allowed on the conductor surface. 5.2 Insulation 5.2.1 The insulating layer of the WDZ-DCYJ-125 Type cables is made of 125°C cross-linked polyolefin insulated materials. The insulating layer of the WDZ-DCYJ/B-125 Type cables is made of high strength 125°C cross-linked polyolefin insulated materials. The insulating layer of the WDZ-DCYJ/B-150 Type cables is made of high strength 150°C cross-linked polyolefin insulated materials. The insulation thickness shall meet the requirements in Table 2, with the mean value not less than the specified nominal value. The thickness of the thinnest point shall not be less than 90% of the nominal value - 0.1 mm. 5.2.2 Non-electrical performance of the insulation shall comply with the provisions in Table 3. 5.2.3 Insulation surface shall be round, smooth and no bump. The insulation layer of Model WDZ-DCYJ-125 Type cable is black. The insulating layer of the WDZ-DCYJ/B-125 Type and WDZ-DCYJ/B-150 Type cables, in general, shall be light brown and it is allowed to determine the color according to the Agreement between the Supplier and the Purchaser. 5.3 Finished cable 5.3.1 External diameter of cable The cable’s external diameter shall comply with the provisions in Table 2. 5.3.2 Out-of-roundness of the cable The difference (f value) between the maximum and minimum external diameters measured on the same cross section of the cable shall not exceed 15% of upper limit of the specified nominal external diameter. 5.3.3 Conductor DC resistance DC resistance of the conductor at 20°C shall comply with the provisions of Table 2. The insulation of the cable shall be remained stable even in the moist condition. And the cable shall withstand the voltage value in direct-current test specified in Table 7 without any breakdown. Table 7 Rated voltage V of the cable Applied voltage V 1,000, 750 1,000 1,500 1,800 3,000 3,600 5.3.16 Vertical flame test for single-cable Under the specified condition, after stopping of fire supply, the cable shall be extinguished by itself. It can be concluded as qualified if the scorched part is less than 50mm away from the lower-edge of upper-jig. 5.3.17 Test on smoke density of the cable Under the specified condition, the light transmission rate shall comply with the provisions of Table 3. 5.3.18 Acidity test of combustion gas The pH value, conductivity and halogen acid content shall comply with the provisions of Table 3. 5.4 Delivery length 5.4.1 The length of looped cable shall be 100 m or integer multiples of 100 m. And the plated cable shall not be less than 100 m. 5.4.2 It is allowed to deliver short-length cable of not less than 30 m, but the quantity of such cable shall not be more than 10% of total l... ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GB 12528.11-2003 be delivered?

Answer: The full copy PDF of English version of GB 12528.11-2003 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB 12528.11-2003_English with my colleagues?

Answer: Yes. The purchased PDF of GB 12528.11-2003_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GB 12528.11-2003 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of GB 12528.11-2003?

A step-by-step guide to download PDF of GB 12528.11-2003_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB 12528.11-2003".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9