HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (6 Oct 2024)

CJ/T 409-2012 PDF in English


CJ/T 409-2012 (CJ/T409-2012, CJT 409-2012, CJT409-2012)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
CJ/T 409-2012English150 Add to Cart 0-9 seconds. Auto-delivery. Technical requirement of fiber-glass reinforced plastic septic tank Valid
Standards related to (historical): CJ/T 409-2012
PDF Preview

CJ/T 409-2012: PDF in English (CJT 409-2012)

CJ/T 409-2012 CJ URBAN CONSTRUCTION INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 91.140 Q 86 Technical Requirement of Fiber-Glass Reinforced Plastic Septic Tank ISSUED ON. NOVEMBER 1, 2012 IMPLEMENTED ON. JANUARY 1, 2013 Issued by. Ministry of Housing and Urban-Rural Development of the People's Republic of China Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative References ... 4  3 Raw Materials ... 5  4 Model and Structure ... 5  5 Requirements ... 6  6 Test Methods ... 7  7 Inspection Rules ... 8  8 Label, Package, Transportation and Storage ... 9  Foreword This Standard was drafted as per the rules specified in GB/T 1.1-2009. This Standard was proposed by Standard and Quantity Institute, Ministry of Housing and Urban-Rural Development. This Standard shall be under the jurisdiction of National Technical Committee for Standardization of Building Water Supply and Drainage - Ministry of Housing and Urban-Rural Development. Drafting organizations of this Standard. Henan Yeajar Environmental Protection Co., Ltd., and Beijing Sino-Japanese Chengqimei Environment Technology Development Co., Ltd. Participating drafting organizations of this Standard. Hebei (Yijia) Jiewei Environ-Tech Co., Ltd., Shaanxi Yijia Environ-Tech Co., Ltd., Fuzhou Yilin Environment Technology Co., Ltd., Hangzhou Jiaqing Environment Technology Co., Ltd., Wuhan Green Tide Environ-Tech Co., Ltd., Guangzhou Kangwei Envrion-Tech Co., Ltd., Ganshu Yijia Environmental Engineering Co., Ltd., Guangxi Nanning Guixiang Environmental Science and Technology Co., Ltd., Hunan Timelion Composite Materials Co., Ltd., Zhangjiagang Wilson Environmental Protection Equipment Co., Ltd., and Shanghai Green Tide Environmental Protection Co., Ltd. Chief drafting staffs of this Standard. Xu Shaorong, Liu Hongqiang, Yang Qingxue, Li Jianzhi, Liang Yanqiang, Hao Jihu, Lin Yongfu, Weng Aifu, Yu Jianjun, Liu Xianqi, Shen Ling, Huang Yuehou, Zeng Jianxiang, Li Wenqing, Liang Xiaohong, Xing Tao, Li Rongxiang, Huang Jianfen, and Han Zhihe. Technical Requirement of Fiber-Glass Reinforced Plastic Septic Tank 1 Scope This Standard specifies the raw material, model and structure, requirements, test methods, inspection rules, label, package, transportation and storage of fiber-glass reinforced plastic septic tank (herein after refers to “septic tank”). This Standard is applicable to the septic tank with raw materials of glass fiber and unsaturated polyester resin. 2 Normative References The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this Standard. GB/T 1447 Test Method for Tensile Properties of Glass Fiber - Reinforced Plastics GB/T 1449 Test Method for Flexural Properties of Glass Fiber - Reinforced Plastics GB/T 1462 Test Methods for Water Absorption of Fiber Reinforced Plastics GB/T 2575 Test Method for Resistance of Glass Fiber Reinforced Plastics to Water GB/T 3854 Test Method for Hardness of Reinforced Plastics By Means of Barcol Impresser GB/T 8237 Liquid Unsaturated Polyester Resin for Fiber Reinforced Plastics GB/T 18369 Glass Fiber Roving GB/T 18370 Glass Fibre Woven Roving GB/T 21238 Glass Fiber Reinforced Plastics Mortar Pipes 6.6 Water absorption rate It shall be measured as per GB/T 1462. 6.7 Water resistance It shall be measured as per GB/T 2575. 6.8 Impact strength In the place over the central position of the septic tank (avoid the cleaning hole), use a 2000g steel ball to conduct free fall from the height 2m; measure at the place where the steel ball impacts. 6.9 Leakage test Fix the septic tank in backfill or other modes; seal the inlet and outlet, fill the tank with water thoroughly; stand for 24h to observe; there shall be no leakage or obvious deformation phenomena. 6.10 Initial ring stiffness It shall be measured as per GB/T 21238. 7 Inspection Rules Inspection is divided into exit-factory inspection and type inspection. 7.1 Exit-factory inspection 7.1.1 Inspection items Before each septic tank leaves the factory, it shall conduct inspection items in 5.1, 5.2 and 5.3.6. 7.1.2 Judgment rules If each item in exit-factory inspection conforms to the requirements, then the product shall be judged as qualified. If there are disqualified items, the product shall be repaired once, then re-inspect; if it is still disqualified after repairing, then judge this batch of products as disqualified. 7.2 Type Inspection 7.2.1 Type inspection conditions Type inspection includes all items in Chapter 5. When one of the following conditions occurs, the type inspection shall be conducted. a) When determining the product model and put into production; b) When raw materials and formulation have significant changes, which may affect the product performance; c) Conduct the inspection every three years for normal production; d) Restore production when shutdown for more than half a year. 7.2.2 Sampling Conduct sampling from the qualified products in exit-factory inspection. 7.2.3 Judgment After inspection, if there are disqualified items, allow for double sampling and re-inspecting. After that, if there are still disqualified items, then such batch of product shall be judged as disqualified. 8 Label, Package, Transportation and Storage 8.1 Label After test is qualified, the products shall have the following labels. a) Trademark; b) Serial number; c) Product name; d) Specification, model; e) Direction marks for the inlet and outlet water pipe; f) Manufacturer name; g) Contact phone; h) Production reference standards. 8.2 Package Generally, the septic tank shall not be packed. When leaving the factory, the septic tank shall have qualification certificate, and ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.