Std ID |
Description (Standard Title) |
|
DL/T 2606-2023
|
(Field Test Method for Oscillating Characteristics of DC Converter)
|
|
DL/T 2637-2023
|
(Specifications for field testing of hybrid high-voltage DC circuit breakers)
|
|
DL/T 2227-2021
|
Selection guide to HV DC transfer switches for +-800 kV and above UHV DC transmission system
|
|
DL/T 2228-2021
|
Regulation of operation and maintenance for gas-filled switchgear panel used in substation
|
|
DL/T 781-2021
|
High frequency switching rectifier module for power system
|
|
DL/T 2113-2020
|
Test specification for hybrid HVDC circuit-breakers
|
|
DL/T 2050-2019
|
Field detecting method for partial discharge of high voltage switchgear based on transient earth voltage
|
|
DL/T 617-2019
|
Specification for gas-insulated metal-enclosed switchgear
|
|
DL/T 1946-2018
|
Guide of X-ray radiography field examination for gas-insulated metal-enclosed switchgear
|
|
DL/T 978-2018
|
Specification for gas-insulated metal-enclosed transmission line
|
|
DL/T 1694.2-2017
|
Calibration specification for high voltage testing instruments -- Part 2: Power transformer tap-changers tester
|
|
DL/T 1694.3-2017
|
Calibration specification for high voltage testing instruments -- Part 3: High voltage switch operating characteristics tester
|
|
DL/T 403-2017
|
High-voltage alternating-current vacuum circuit-breaker
|
|
DL/T 603-2017
|
Regulation of operation and maintenance for gas-insulated metal-enclosed switchgear
|
|
DL/T 1551-2016
|
Determination of sulfur dioxide, hydrogen sulfide, sulfuryl fluoride and thionyl fluoride in sulfur hexafluoride - Gas chromatography-mass spectrometry
|
|
DL/T 1553-2016
|
Regulation of sulfur hexafluoride gas recovery and purification procession
|
|
DL/T 1555-2016
|
Guide for operation and maintenance of sulfur hexafluoride on-line leakage monitoring and alarming equipments
|
|
DL/T 1586-2016
|
12 kV solid insulated metal -- Enclosed switchgear and controlgear
|
|
DL/T 1630-2016
|
Technical specification for UHF partial discharge detection in gas-insulated metal-enclosed switchgear
|
|
DL/T 595-2016
|
Rules for supervising SF6 gas in electrical equipment
|
|
DL/T 639-2016
|
Safety and protection guide for operation test and maintenance personnel of SF6 electrical equipment
|
|
DL/T 1411-2015
|
Technical guide for smart high voltage equipment
|
|
DL/T 1441-2015
|
Technical conditions for intelligent low-voltage distribution box
|
|
DL/T 1442-2015
|
Technical conditions for intelligent distribution transformer terminal
|
|
DL/T 1221-2013
|
Universal specification for transformer characteristic tester
|
|
DL/T 1222-2013
|
Calibration specification of impulse voltage dividers
|
|
DL/T 690-2013
|
Synthetic testing of high-voltage alternating current circuit-breakers
|
|
DL/T 1152-2012
|
Universal specification about voltage tester for secondary circuit of voltage transformer
|
|
DL/T 1183-2012
|
Non-contact voltage detectors for 1000kV UHV AC
|
|
DL/T 250-2012
|
General specifications for shunt capacitor protection equipment
|
|
DL/T 252-2012
|
General specifications for HVDC converter transormer protection equipment
|
|
DL/T 311-2010
|
Guide for AC 1100kV GIS/HGIS maintenance
|
|
DL/T 361-2010
|
Technical guide for usage of gas-insulated metal-enclosed transmission line
|
|
DL/T 375-2010
|
General technical condition for outdoor distribution box
|
|
DL/T 391-2010
|
The maintenance code of 12kV outdoor highvoltage vacuum circuit-breaker
|
|
DL/T 406-2010
|
Specification for automatic line sectionalizers for AC systems
|
|
DL/T 486-2010
|
High-voltage alternating-current disconnectors and earthing switches
|
|
DL/T 617-2010
|
Specification for Gas-insulated metal-enclosed switchgear
|
|
DL/T 687-2010
|
General specification for preventing electric mal-operation system with computer
|
|
DL/T 737-2010
|
The operated management standard of unattend-substation for the rural electric power network
|
|
DL/T 402-2007
|
Specification of high-voltage alternating-current circuit-breakers
|
|
DL/T 404-2007
|
Alternating. Current metal-enclosed Switchgear and controlgear for rated voltages above 3.6kV and up to and including 40.5kV
|
|
DL/T 506-2007
|
Method of humidity measurement of SF6 insulated gas in electrical equipment
|
|
DL/T 1032-2006
|
Sampling method of sulphur hexafluoride (SF6) used by electrical equipment
|
|
DL/T 413-2006
|
Technical requirements of heat shrinkable accessories for power cable with rated voltages up to 35kV(Um=40.5kV)
|
|
DL/T 538-2006
|
High-voltage presence indicating systems
|
|
DL/T 593-2006
|
Common specifications for high-voltage switchgear and controlgear standards
|
|
DL/T 603-2006
|
Regulation of operation and preventive maintenance for gas-insulated metal-enclosed switchgear
|
|
DL/T 978-2005
|
Specification for gas-insulated metal-enclosed transmission line
|
|
DL/T 844-2003
|
General specification for 12kV minimum maintenance outdoor distribution switchgears
|
|
DL/T 781-2001
|
High frequency switching converter module in power system
|
|
DL/T 791-2001
|
Specification of indoor ac HV gas-filled switchgear panel
|
|
DL/T 403-2000
|
HV vacuum circuit-breaker for rated voltage 12kv to 40.5kv
|
|
DL/T 486-2000
|
Specifications for HV AC disconnectors and earthing switches
|
|
DL/T 728-2000
|
Technical guide for the order of Gas-insulated metal-enclosed switchgear
|
|
DL/T 739-2000
|
LW-10 type SF6 circuit breaker repairing technique rules
|
|
DL/T 402-1999
|
High-voltage alternating current circuit-breakers
|
|
DL/T 687-1999
|
General specification for prevent electric mal-operation device with computer
|
|
DL/T 690-1999
|
Synthetic testing of high-voltage alternating current circuit-breakers
|
|
DL/T 404-1997
|
Indoor AC high voltage switchgear panel
|
|
DL/T 615-1997
|
Guide to the selection of characteristic quantities of HV AC circuit-breakers
|
|
DL/T 617-1997
|
Specification for Gas-insulated metal-enclosed switchgear
|
|
DL/T 618-1997
|
Code for hand-over test of gas-insulated metal-enclosed switchgear on site
|
|
DL/T 640-1997
|
Technical condition for order of the ourdoor a.c high-voltage drop-out fuse and the fuse-link
|
|
DL/T 405-1996
|
Technical specifications for import 252 (245)~550kV a. c. high-voltage circuit-breakers and disconnectors
|
|
DL/T 593-1996
|
Common specifications for HV switchgear enquiries and orders
|
|
DL/T 594-1996
|
Specification for industrial rigid laminated sheets based on thermosetting resins for HV switchgear
|
|
DL/T 603-1996
|
Regulation of operation and preventive maintenance for gas-insulated metal-enclosed switchgear
|
|
DL/T 574-1995
|
Guiding principle for operating and maintaining on-load tap switches
|
|
DL/T 555-1994
|
Guide for Withstand Voltage Test of Gas-Insulated Metal-Enclosure Electric Appliance on Site
|
|
DL/T 538-1993
|
Technical Specifications of High-voltage Presence Indicating Systems
|
|
DL/T 539-1993
|
Technical conditions for condensation and pollution test on high-voltage switch cabinets and elements
|
|
DL/T 486-1992
|
Specifications for HV AC Disconnectors Switches
|
|
DL 427-1991
|
Technical conditions for ordering indoor type generator circuit breakers
|
|
DL/T 402-1991
|
(Chinese Industry Standard)
|
|
DL/T 403-1991
|
Indoor HV Vacuum Circuit-Breaker for Rated Voltage 10kv to 35kv
|
|
DL/T 404-1991
|
(Chinese Industry Standard)
|
|
DL/T 405-1991
|
(Chinese Industry Standard)
|
|
DL/T 406-1991
|
Technical conditions for ordering alternating current automatic sectionalizers
|
|
DL/T 840-2024
|
(Technical conditions for use of high voltage shunt capacitors)
|
|
DL/T 2633-2023
|
(Technical Guidelines for DC Capacitors Used in Flexible DC Converters)
|
|
DL/T 2635-2023
|
(Technical conditions for DC coupling capacitors and capacitive voltage dividers for DC transmission)
|
|
DL/T 536-2023
|
(Technical conditions for use of AC coupling capacitors and capacitive voltage dividers)
|
|
DL/T 653-2023
|
(Technical conditions for use of discharge coils for high-voltage parallel capacitors)
|
|
DL/T 2207-2021
|
Noise measurement of power capacitors
|
|
DL/T 2229-2021
|
Technical specifications for high voltage ceramic capacitance sensor up to 35 kV
|
|
DL/T 2306-2021
|
Specification for DC capacitor of HVDC convertor station for service
|
|
DL/T 604-2020
|
Technical specification of high-voltage shunt capacitor installation
|
|
DL/T 1562-2016
|
Calibration specification of capacitive equipment monitoring device
|
|
DL/T 1633-2016
|
Specification of compact high-voltage shunt capacitor installations for service
|
|
DL/T 1647-2016
|
Specification of high-voltage fireproof power capacitors for service
|
|
DL/T 840-2016
|
Specification of high-voltage shunt capacitors for service
|
|
DL/T 1415-2015
|
Guide for the protection of high voltage shunt capacitor installations
|
|
DL/T 1417-2015
|
Code of operation for low voltage reactive power compensation device
|
|
DL/T 5726-2015
|
Technology Guideline of 1000 kV Series Capacitor Compensation Device Construction
|
|
DL/T 740-2014
|
Capacitive type voltage detectors
|
|
DL/T 1219-2013
|
Design guide for series capacitor installation
|
|
DL/T 1220-2013
|
Code for hand-over tests of series capacitor installation
|
|
DL/T 1274-2013
|
Technical specification of series capacitor installation for 1000kV system
|
|
DL/T 5289-2013
|
Construction technology guide to the assembly and erection of the steel towers of 1000kV overhead transmission line
|