HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

YS/T 861.1-2013 English PDF

US$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 861.1-2013: Mehtods for chemical analysis of niobium-titanium alloy. Part 1: Determination of aluminium, nickel, silicon, iron, chromium, copper and tantalum content. Inductively coupled plasma atomic emission spectrometry
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 861.1-2013English209 Add to Cart 3 days [Need to translate] Mehtods for chemical analysis of niobium-titanium alloy. Part 1: Determination of aluminium, nickel, silicon, iron, chromium, copper and tantalum content. Inductively coupled plasma atomic emission spectrometry Valid YS/T 861.1-2013

PDF similar to YS/T 861.1-2013


Standard similar to YS/T 861.1-2013

YS/T 896   GB/T 4325.5   GB/T 3458   YS/T 861.3   YS/T 861.4   YS/T 861.2   

Basic data

Standard ID YS/T 861.1-2013 (YS/T861.1-2013)
Description (Translated English) Mehtods for chemical analysis of niobium-titanium alloy. Part 1: Determination of aluminium, nickel, silicon, iron, chromium, copper and tantalum content. Inductively coupled plasma atomic emission spectrometry
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H63
Classification of International Standard 77.120.99
Word Count Estimation 8,833
Regulation (derived from) Ministry of Industry and Information Technology Bulletin 2013 No. 23; industry standard filing Notice 2013 No. 7 (No. 163 overall)
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This standard specifies the niobium-titanium alloy of aluminum, nickel, silicon, iron, chromium, copper, tantalum content measurement method. This standard applies to Ni alloy of aluminum, nickel, silicon, iron, chromium, copper, tantalum content.

YS/T 861.1-2013: Mehtods for chemical analysis of niobium-titanium alloy. Part 1: Determination of aluminium, nickel, silicon, iron, chromium, copper and tantalum content. Inductively coupled plasma atomic emission spectrometry



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Mehtods for chemical analysis of niobium-titanium alloy Part 1. Determination of aluminium, nickel, silicon, iron, chromium, copper and tantalum content Inductively coupled plasma atomic emission spectrometry ICS 77.120.99 H63 People's Republic of China Nonferrous Metals Industry Standard Niobium-titanium alloys Part 1. aluminum, nickel, silicon, iron, chromium, copper, Determination of tantalum content Inductively coupled plasma atomic emission spectrometry Part 1. Determinationofaluminium, nickel, silicon, iron, chromium, Issued on. 2013-09-01 2013-04-25 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

YS/T 861 "niobium-titanium alloy chemical analysis method" is divided into five sections. --- Part 1. aluminum, nickel, silicon, iron, chromium, copper, tantalum content - Inductively coupled plasma atomic emission spectrometry; --- Part 2. oxygen, the determination of nitrogen inert gas fusion infrared absorption/thermal conductivity method; --- Part 3. Determination of hydrogen content of inert gas fusion thermal conductivity method; --- Part 4. Determination of carbon content in the high-frequency combustion infrared absorption method; --- Part 5. Determination of the amount of titanium ammonium ferric sulfate titration. This section YS/T 861 - Part 1. This section drafted in accordance with GB/T 1.1-2009 given rules. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is drafted. Western Metal Materials Co., Ltd., Guangzhou Nonferrous Metal Research Institute, Beijing Nonferrous Metal Research Institute. The main drafters of this section. Tuo Li, Yang Jun Hong, Zhai through Germany, Zhang Bin, Li Juan, inch Jinxia, Xiong Xiaoyan, Redevex school, Wang Jin, Li Jidong, Wang Changhua. Niobium-titanium alloys Part 1. aluminum, nickel, silicon, iron, chromium, copper, tantalum content determination Inductively coupled plasma atomic emission spectrometry

1 Scope

This section YS/T 861 provides for aluminum, nickel, silicon, iron, chromium, copper, tantalum content determination of niobium titanium alloy. This section applies to the determination of niobium-titanium alloy of aluminum, nickel, silicon, iron, chromium, copper, tantalum content, the measurement range shown in Table 1. Table 1 Element measurement range /% Al 0.0030 ~ 0.020 Ni 0.0030 ~ 0.020 Si 0.0050 ~ 0.020 Fe 0.0050 ~ 0.020 Cr 0.0030 ~ 0.020 Cu 0.0030 ~ 0.020 Ta 0.010 ~ 0.40

2 Method summary

Sample decomposition with hydrofluoric acid and nitric acid. Solution directly to the argon plasma excitation source, subjected to spectral measurement, calculated from the measured elements content.

3 Reagents

Unless otherwise indicated, this part of the reagents are excellent pure reagent, which is a water or equivalent purity water. 3.1 Hydrofluoric acid (ρ = 1.14g/mL). 3.2 nitric acid (ρ = 1.42g/mL). 3.3 hydrochloride (11). 3.4 nitric acid (11). 3.5 Hydrofluoric acid (11). Argon 3.6 volume fraction ≥99.995%. 3.7 highly pure titanium, the measured element content < 0.001%. 3.8 high-purity niobium or niobium hydroxide, the measured element content < 0.001%. 3.9 standard aluminum stock solution. Weigh 1.0000g of aluminum (wAl≥99.99%), placed in 250mL beaker covered with a watch glass, add 100mL of hydrochloric acid (3.3), a low temperature to dissolve. Until completely dissolved and then cooled and transferred to 1000mL volumetric flask, dilute with water to volume, and mix.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 861.1-2013_English be delivered?

Answer: Upon your order, we will start to translate YS/T 861.1-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 861.1-2013_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 861.1-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.