US$159.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 861.4-2013: Methods for chemical analysis of niobium-titanium alloy. Part 4: Determination of carbon content. The high-frequency infrared absorption method Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YS/T 861.4-2013 | English | 159 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of niobium-titanium alloy. Part 4: Determination of carbon content. The high-frequency infrared absorption method
| Valid |
YS/T 861.4-2013
|
PDF similar to YS/T 861.4-2013
Basic data | Standard ID | YS/T 861.4-2013 (YS/T861.4-2013) | | Description (Translated English) | Methods for chemical analysis of niobium-titanium alloy. Part 4: Determination of carbon content. The high-frequency infrared absorption method | | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | | Classification of Chinese Standard | H63 | | Classification of International Standard | 77.120.99 | | Word Count Estimation | 6,618 | | Regulation (derived from) | Ministry of Industry and Information Technology Bulletin 2013 No. 23; industry standard filing Notice 2013 No. 7 (No. 163 overall) | | Issuing agency(ies) | Ministry of Industry and Information Technology | | Summary | This standard specifies the niobium-titanium alloy materials, method of measuring the amount of carbon. This standard applies to niobium-titanium alloy materials Determination of carbon content, Measuring range: 0. 0020% to 0. 10%. |
YS/T 861.4-2013: Methods for chemical analysis of niobium-titanium alloy. Part 4: Determination of carbon content. The high-frequency infrared absorption method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of niobium-titanium alloy Part 4. Determination of carbon content The high-frequency infrared absorption method
ICS 77.120.99
H63
People's Republic of China Nonferrous Metals Industry Standard
Niobium-titanium alloys
Part 4. Determination of carbon contents
Frequency combustion infrared absorption method
Part 4. Determinationofcarboncontent-
Issued on. 2013-04-25
2013-09-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
YS/T 861 "niobium-titanium alloy chemical analysis method" is divided into five sections.
--- Part 1. aluminum, nickel, silicon, iron, chromium, copper, tantalum content - Inductively coupled plasma atomic emission spectrometry;
--- Part 2. oxygen, the determination of nitrogen inert gas fusion infrared absorption/thermal conductivity method;
--- Part 3. Determination of hydrogen content of inert gas fusion thermal conductivity method;
--- Part 4. Determination of carbon content in the high-frequency combustion infrared absorption method;
--- Part 5. Determination of the amount of titanium ammonium ferric sulfate titration.
This section YS/T Section 4861 of.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is drafted. West Co., Ltd., Northwest Nonferrous Metal Research Institute, Guangzhou Nonferrous Metal Research Institute of metal materials.
Drafters of this section. Cao Haihua, Zhao Fei, Wei Dong, Li Tuo, a new layer of stone, Fang, Zheng Wei, Li Bo, Wang Hui, Zhuang Yichun, Wang Jin, Zhang Jin.
Niobium-titanium alloys
Part 4. Determination of carbon contents
Frequency combustion infrared absorption method
1 Scope
YS/T 861 This part specifies the method for the determination of carbon content of niobium-titanium alloy material.
This section applies to the determination of niobium-titanium alloy material in the amount of carbon, measuring range. 0.0020% to 0.10%.
2 Method summary
Sample combustion in oxygen to produce carbon dioxide or carbon monoxide in a high frequency induction furnace, carbon monoxide is converted into carbon dioxide catalytic furnace,
Carbon dioxide in the infrared cell detection.
3 Reagents
3.1 W flux (carbon content of not more than 0.0005%).
3.2 Ceramic crucible. a muffle furnace at 1000 ℃ ~ 1100 ℃ in burning at least after 2h, placed in a desiccator save.
3.3 Oxygen. volume fraction ≥99.5%.
3.4 Standard sample. sample selection and composition, carbon content similar to standard samples or other applicable standard sample.
4 Instrument
High-frequency infrared carbon and sulfur analyzer. Instrument sensitivity is not less than 0.00001%.
5 Sample
5.1 sample uniform crumb-like samples.
5.2 processes to avoid overheating the sample, allowed to use any coolant samples should be processed to prevent contamination.
Step 6 Analysis
6.1 Warm up
To fully preheated before instrumental analysis, so that the indicators of the instrument reaches the set value.
6.2 Instrument Leak
The use of the instrument or other auxiliary equipment leak detection program to determine the instrument without leakage phenomenon.
6.3 Instrument Calibration
Calibrated with standard samples (3.4), make the analysis value within the allowable fluctuation range of the standard values.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 861.4-2013_English be delivered?Answer: Upon your order, we will start to translate YS/T 861.4-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 861.4-2013_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 861.4-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|