HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (1 Nov 2025)

SN/T 2616-2010 English PDF

US$369.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 2616-2010: Rapid detection of Yersinia pestis and Hantavirus on rodents at frontier port
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 2616-2010English369 Add to Cart 3 days [Need to translate] Rapid detection of Yersinia pestis and Hantavirus on rodents at frontier port Valid SN/T 2616-2010

PDF similar to SN/T 2616-2010


Standard similar to SN/T 2616-2010

GBZ 57   GB/T 31989   SN/T 2609   SN/T 2610   SN/T 2608   

Basic data

Standard ID SN/T 2616-2010 (SN/T2616-2010)
Description (Translated English) Rapid detection of Yersinia pestis and Hantavirus on rodents at frontier port
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard C62
Classification of International Standard 13.020
Word Count Estimation 14,113
Date of Issue 2010-05-27
Date of Implementation 2010-12-01
Quoted Standard GB 19489; SN/T 1280; SN/T 1552; WS 233; 2005 National Monitoring Programme of hemorrhagic fever with renal syndrome (Trial)
Regulation (derived from) National Quality Inspection (2010) 290; industry standard filing Notice 2010 No. 10 (No. 130 overall)
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the port to capture rats carried the plague bacillus of hemorrhagic fever with renal syndrome and hantavirus (I and type ��) rapid pathogen detection methods, including sample collection and pathogen testing materials preservation, rapid detection of pathogenic antibodies and nucleic acids and results analysis and interpretation. This standard applies to plague rat rod seedlings and carry hantavirus (I and type ��) detection.

SN/T 2616-2010: Rapid detection of Yersinia pestis and Hantavirus on rodents at frontier port

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rapid detection of Yersinia pestis and Hantavirus on rodents at frontier port People's Republic of China Entry-Exit Inspection and Quarantine Standards Border crossings and rats carry the plague bacillus Hantavirus rapid detection method Issued on. 2010-05-27 2010-12-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. Chinese Academy of Inspection and Quarantine, Shenzhen People's Republic of China Exit Inspection and Quarantine, the People's Republic of China Exit Inspection and Quarantine and the National Jilin. The main drafters of this standard. new hole Hu Shi Lei, Zhao vigorously, Pengfei, flat towel Rui, Wang Jing, Sun Xiaohong, Yang Yu, Zhang Yue. Border crossings and rats carry the plague bacillus Hantavirus rapid detection method

1 Scope

This standard specifies the mouse port capture carried Yersinia pestis and Hantavirus hemorrhagic fever with renal syndrome (Ⅰ and type Ⅱ) Rapid Pathogen Detection The method, including pathogen sample collection and preservation of the test material, the pathogenic antibodies and nucleic acid detection and rapid analysis of the results and interpretation. This standard applies to Y. pestis and mice carry hantavirus (Ⅰ and type Ⅱ) detection.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member, undated references, the latest edition (including any amendments) applies to this document. GB 19489 General requirements for laboratory biosafety SN/T 1280 frontier port inspection of Plague SN/T 1552 terrorist attacks biological factors frontier port monitoring procedures WS233 Microbiological and Biomedical Laboratories Biosafety Common Criteria In 2005 the national monitoring program hemorrhagic fever with renal syndrome (Trial)

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 Hemorrhagicfeverwithrenalsyndrome hemorrhagic fever with renal syndrome Bunia by the virus is a virus mainly by Ke Hantan Ⅰ and type Ⅱ caused by hantavirus in rodents as the main source of infection for a person Class life serious health hazards common natural foci of disease. Typical clinical manifestations were fever, bleeding, shock, kidney damage. 4 bio-safety requirements 4.1 before the investigation and proper personal protection. Protection methods and standards, see SN/T 1552. 4.2 The laboratory shall follow the biosafety requirements GB 19489 and WS233 for biosafety level 2 (BSL-2) laboratory. 4.3 Used Lab Supplies shall comply with GB 19489 requirements for the processing of waste treatment and disposal.

5 test subject

And the port area to capture rodents entry and exit vehicles, transport equipment, goods, luggage, parcels and other hiding and capture (including other murine Type animals).

6 ready

6.1 Laboratory Biosafety two (BSL-2 or P2) or more laboratory and corresponding facilities.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 2616-2010_English be delivered?

Answer: Upon your order, we will start to translate SN/T 2616-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 2616-2010_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 2616-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information