JJG 662-2005: Verification regulation of paramagnetic oxygen analyzer
Status: Valid

JJG 662: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 662-2005English339 Add to Cart 3 days [Need to translate] Verification regulation of paramagnetic oxygen analyzer Valid JJG 662-2005
JJG 662-1990English439 Add to Cart 4 days [Need to translate] Verification Regulation of Thermo-Magnetic Oxygen Analyzers Obsolete JJG 662-1990

PDF similar to JJG 662-2005


Standard similar to JJG 662-2005

JJG 631   JJG 635   JJG 695   JJG 657   JJG 672   JJG 656   

Basic data

Standard ID JJG 662-2005 (JJG662-2005)
Description (Translated English) Verification regulation of paramagnetic oxygen analyzer
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A61
Classification of International Standard 17
Word Count Estimation 13,191
Date of Issue 2005-04-28
Date of Implementation 2005-10-28
Older Standard (superseded by this standard) JJG 662-1990
Summary This standard applies to paramagnetic oxygen (including thermal-magnetic oxygen, oxygen pressure type magnetic, magneto mechanical oxygen) analyzer initial verification, testing and use of follow-up inspection,

JJG 662-2005: Verification regulation of paramagnetic oxygen analyzer

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification regulation of paramagnetic oxygen analyzer National Metrology Verification Regulations of the People's Republic Paramagnetic oxygen analyzer Released on.2005-04-28 2005-10-28 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued Replacing JJG 662-1990 This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on April 28,.2005, and Implemented on October 28,.2005. Focal Point. National Physical and Chemical Metrology Technical Committee Main drafting unit. National Standards Research Center Participated in the drafting unit. Quality Inspection Bureau of Ningbo Quality and Technical Supervision Bureau This procedure entrusts the National Physical and Chemical Metrology Technical Committee to explain The main drafters of this procedure. Li Chunxi (National Reference Materials Research Center) Participate in the drafters. Guan Yihe (Ningbo Quality and Technical Supervision Bureau Quality Inspection Institute) Yu Dengyu (National Standards Research Center) Zhang Peizhuang (National Standards Research Center)

table of Contents

1 Scope (1) 2 Overview (1) 3 Metrological performance requirements (1) 3.1 Instrument level and indication error limits (1) 3.2 Repeatability (1) 3.3 Response time (1) 3.4 Stability (1) 3.4.1 Zero drift (1) 3.4.2 Indication drift (1) 4 General technical requirements (2) 4.1 Appearance and Functional Inspection (2) 4.2 Insulation resistance (2) 4.3 Dielectric strength (2) 5 Control of measuring instruments (2) 5.1 Verification conditions (2) 5.2 Verification project (3) 5.3 Verification method (3) 5.4 Processing of verification results (5) 5.5 Verification cycle (5) Appendix A Format of the certificate and the result of the verification result (6) Appendix B Verification Record Format (7) Paramagnetic oxygen analyzer verification procedure

1 Scope

This procedure applies to the first time for paramagnetic oxygen (including thermomagnetic oxygen, magnetic pressure oxygen, magnetic mechanical oxygen) analyzers. Verification, follow-up verification and in-use inspection.

2 Overview

Thermomagnetic oxygen analyzer, magnetic pressure oxygen analyzer, magnetic mechanical oxygen analyzer are usually online detection (or supervision) Meter) for continuous automatic analysis of the oxygen content of the gas. Its working principle is based on the paramagnetism of oxygen. Use oxygen Is attracted in the magnetic field to produce corresponding thermomagnetic convection (thermomagnetic), pressure difference (magnetic pressure), density gradient (magnetic Mechanical), and through the detection of components to convert thermomagnetic convection, pressure difference, density gradient into electrical signals, thereby achieving The measurement of the oxygen concentration in the gas is measured.

3 Metrological performance requirements

3.1 Instrument level and indication error limits For different classes of instruments, the corresponding indication error limits shall be in accordance with Table 1 within the range of their ranges. Table 1 Instrument level and indication error limits Instrument level indication error limit /%FS 1.0 ± 1.0 1.5 ± 1.5 2.5 ± 2.5 5.0 ± 5.0 3.2 Repeatability Under the same conditions, the same standard gas is measured 6 times, and the relative standard deviation should be no more than the corresponding indication. The error limit is 1/2 of the absolute value. 3.3 Response time Thermomagnetic oxygen analyzer. no more than 50s; Magnetic pressure oxygen analyzer, magnetic mechanical oxygen analyzer. no more than 30s. 3.4 Stability 3.4.1 Zero drift The instrument runs continuously for 4 hours, and the zero drift should not exceed the indication error limit. 3.4.2 indication drift The instrument is continuously operated for 4h, and the indication value drift should not exceed the indication error limit. For the first run of the instrument, the zero running time and the continuous running time of the indication drift should refer to the instrument manual.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 662-2005_English be delivered?

Answer: Upon your order, we will start to translate JJG 662-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 662-2005_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 662-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 662-2005?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 662-2005 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.