HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

JJG 672-2018 English PDF

US$419.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 672-2018: Bomb Calorimeters
Status: Valid

JJG 672: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 672-2018English419 Add to Cart 4 days [Need to translate] Bomb Calorimeters Valid JJG 672-2018
JJG 672-2001English599 Add to Cart 4 days [Need to translate] Verification Regulation of The Bomb Calorimeler Obsolete JJG 672-2001
JJG 672-1990English559 Add to Cart 4 days [Need to translate] (Isothermal oxygen bomb calorimeter test procedures) Obsolete JJG 672-1990

PDF similar to JJG 672-2018


Standard similar to JJG 672-2018

JJG 631   JJG 635   JJG 695   JJG 499   JJG 551   JJG 680   

Basic data

Standard ID JJG 672-2018 (JJG672-2018)
Description (Translated English) Bomb Calorimeters
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A61
Classification of International Standard 17.200
Word Count Estimation 18,175
Date of Issue 2018-12-25
Date of Implementation 2019-06-25
Older Standard (superseded by this standard) JJG 672-2001
Quoted Standard GB/T 213-2008; MT/T 737
Regulation (derived from) Natural Resources Department Announcement No. 7 of 2019
Issuing agency(ies) State Administration for Market Regulation
Summary This standard applies to the first verification, subsequent verification and in-use inspection of isothermal and adiabatic oxygen bomb calorimeters.

JJG 672-2018: Bomb Calorimeters

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Bomb Calorimeters National Metrology Verification Regulations of the People's Republic Oxygen bomb calorimeter Published on.2018-12-25 2019-06-25 implementation State Market Supervisory Administration released Oxygen bomb calorimeter verification procedure Replace JJG 672-2001 Focal Point. National Physical and Chemical Metrology Technical Committee Main drafting unit. China Institute of Metrology Participated in the drafting unit. Hunan Institute of Metrology and Inspection This procedure entrusts the National Physical and Chemical Metrology Technical Committee to explain The main drafters of this procedure. Wang Haifeng (China Institute of Metrology) Li Jia (China Institute of Metrology) Meng Fanmin (China Institute of Metrology) Participate in the drafters. Thursday Qing (Hunan Province Metrology and Testing Institute)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 terms (1) 4 Overview (1) 5 Metrological performance requirements (2) 6 General technical requirements (2) 6.1 Legal measurement management signs and signs (2) 6.2 Appearance requirements (2) 6.3 Oxygen bomb safety performance requirements (2) 7 measuring instrument control (2) 7.1 Verification conditions (2) 7.2 Verification items and verification methods (3) 7.3 Processing of verification results (5) 7.4 Verification cycle (5) Appendix A Thermal Capacity Calibration Method for Oxygen Bomb Calorimeter (6) Appendix B Calculation Method of Caloric Value of Benzoic Acid (9) Appendix C Oxygen Bomb Calorimeter Calibration Original Record Format (10) Appendix D Verification certificate/verification result notice page format (11)

Introduction

Compared with JJG 672-2001, the main technical contents except for editorial changes are as follows. --- Added introduction; --- Added reference files (see 2); --- Added terminology (see 3); --- Cancel the "stirring heat", "heat capacity repeatability" and "balance point stability" verification project; --- Added "heat value repeatability" verification project (see Table 1); --- Revised the "heat value indication error" verification project (see Table 1); --- Cancel the "temperature measurement system requirements" in the general technical requirements; --- Revised the "method of verification of calorific value error" (see 7.2.3); --- Added "validation method for calorific value repeatability" (see 7.2.4); --- Added "thermal capacity calibration method for oxygen bomb calorimeter" (see Appendix A); --- Added "calculation method for calorific value of benzoic acid" (see Appendix B); --- Added "Oxygen Bomb Calorimeter Calibration Original Record Format" (see Appendix C); --- Added "Verification Certificate/Verification Result Notice Page Format" (see Appendix D). The previous release of this procedure. ---JJG 672-2001; ---JJG 672-1990 and JJG 673-1990. Oxygen bomb calorimeter verification procedure

1 Scope

This procedure applies to the first verification, subsequent verification and in-use inspection of isothermal and adiabatic oxygen bomb calorimeters.

2 reference files

This procedure refers to the following documents. GB/T 213-2008 Determination method of calorific value of coal MT/T 737 calorimeter oxygen bomb safety performance inspection specification For dated references, only dated versions apply to this Code; any undated quotation The latest version (including all amendments) applies to this procedure.

3 terms

Calorimeter heat capacity heatcapacityofthecalorimeter Referred to as heat capacity, it refers to the heat required to generate a unit temperature rise in a calorimetric system, usually in joules per Kelvin (J/K). Said.

4 Overview

Oxygen bomb calorimeters are meters used to measure the heat of combustion of solid and liquid fuels. The structure of the oxygen bomb calorimeter is shown in the figure 1 is shown. The measurement principle is that a certain amount of sample is burned in an oxygen bomb filled with excess oxygen, and the heat released makes the whole The calorimetric system (including the oxygen bomb, the water in the inner cylinder and the inner cylinder, the agitator and the thermometer) rises in temperature; then according to the heat Calculate the calorific value of the sample by measuring the heat capacity, the temperature rise of the calorimetric system, and the sample quality. Heat capacity of oxygen bomb calorimeter It is determined by burning a certain amount of benzoic acid combustion heat standard substance under similar conditions. Oxygen bomb calorimeters can be divided into isothermal and adiabatic types from the calorimetric principle. The calorimetric system of the isothermal oxygen bomb calorimeter is charged Surrounded by a water-filled outer cylinder that maintains a constant temperature. The sample burns in the oxygen bomb to raise the temperature of the calorimetric system while The outer cylinder water temperature remains unchanged. The calorimetric system of the adiabatic oxygen bomb calorimeter is filled with water and the temperature can change rapidly. Surrounded by. The sample burns in the oxygen bomb to raise the temperature of the calorimetric system, and the temperature of the outer cylinder automatically tracks the temperature of the inner cylinder, so that There is no heat exchange between the inner and outer cylinders.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 672-2018_English be delivered?

Answer: Upon your order, we will start to translate JJG 672-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 672-2018_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 672-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 672-2018?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 672-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.