Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusGoogle Book
JJF 1088-2015English649 Add to Cart 5 days Calibration Specification for Large Dimension Outside Micrometers JJF 1088-2015 Valid JJF 1088-2015
JJF 1088-2002English879 Add to Cart 6 days Calibration Specification for Micrometers with Measuring Range from 500mm to 3000mm JJF 1088-2002 Obsolete JJF 1088-2002


   
BASIC DATA
Standard ID JJF 1088-2015 (JJF1088-2015)
Description (Translated English) Calibration Specification for Large Dimension Outside Micrometers
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Classification of International Standard 17.04
Word Count Estimation 28,289
Date of Issue 2015-08-24
Date of Implementation 2016-02-24
Older Standard (superseded by this standard) JJF 1088-2002
Quoted Standard JB/T 10007-2012; GB/T 1216
Drafting Organization Heilongjiang Institute of measurement test, Guilin measuring tool cutting tool limited liability company
Administrative Organization National Technical Committee for Geometrical Engineering Parameter Measurement
Regulation (derived from) AQSIQ Announcement 2015 No.106
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the calibration value of 0.01mm, the measurement range is (500 ~ 1000) mm, (1000 ~ 3000) mm large diameter micrometer calibration.


JJF 1088-2015: PDF in English
JJF 1088-2015
Calibration Specification for Large Dimension Outside Micrometers
People's Republic of China National Metrology Technical Specifications
Large outside micrometer calibration specification
Issued on. 2015-08-24
2016-02-24 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Large outside micrometer calibration specification
Replacing JJF 1088-2002
NFP. National Engineering Geometrical Parameters Measurement Technology Committee
Main drafting unit. Heilongjiang Provincial Academy of verification test
Guilin Measuring & Cutting Tool Co., Ltd.
Participated in the drafting unit. Liaoning Provincial Institute of Metrology
Hegang City Quality Supervision, Inspection and Testing Center
This specification project commissioned by the National geometric parameter measurement technology committee responsible for the interpretation
The main drafters of this specification.
Liang Yuhong (Heilongjiang Provincial Academy of verification test)
Xu-Hui Li (Heilongjiang Provincial Academy of verification test)
Zhao Weirong (Guilin Measuring & Cutting Tool Co., Ltd.)
Drafters participate.
Tao (Heilongjiang Provincial Academy of verification test)
Na Liu (Liaoning Provincial Institute of Metrology)
Panguan Chen (Hegang City Quality Supervision, Inspection and Testing Center)
table of Contents
Introduction (Ⅲ)
1 Scope (1)
2. References (1)
3 Overview (1)
4 Metrological characteristics (2)
4.1 anvil surface and measuring the relative offsets micrometer screw measuring surface (2)
4.2 load and load change (2)
4.3 differential cylinder tapered end surface edge to the distance scale marks fixed casing surface (2)
4.4 relative positional differential cylinder end face of the fixed cone sleeve millimeter scale marks (2)
4.5 measuring surface roughness of the surface (3)
Anvil and the flatness of 4.6 micrometer screw measuring surface (3)
4.7 two measuring surface Parallelism (3)
Indication error of 4.8 micrometer head (4)
Large 4.9 micrometer diameter indication error (4)
Return error indicator 4.10 (4)
4.11 The amount of proofreading rod (4)
Calibration Condition 5 (4)
Environmental conditions 5.1 (4)
5.2 Calibration standards and project control and ancillary equipment (5)
Calibration Method 6 (5)
6.1 anvil surface and measuring the relative offset (6) micrometer screw measuring surface
6.2 load and load change (6)
6.3 differential cylinder tapered end surface edge to the distance scale marks fixed casing surface (6)
6.4 relative positional differential cylinder end face of the fixed cone sleeve millimeter scale marks (6)
6.5 measuring surface roughness of the surface (7)
6.6 anvil and flatness (7) micrometer screw measuring surface
6.7 two parallel measuring surface (7)
Indication error of 6.8 micrometer head (7)
Large 6.9 micrometer diameter indication error (8)
Return error indicator 6.10 (9)
6.11 proofreading dosage lever (9)
7 Calibration result expression (9)
8 Recalibration interval (9)
APPENDIX A large outside micrometer Measurement Uncertainty about Indication Error Calibration Results Evaluation
(Measuring range 500mm ~ 1000mm) (10)
Appendix B Large micrometer diameter Measurement Uncertainty about Indication Error Calibration Results Evaluation
(Measuring range 1000mm ~ 3000mm) (14)
Appendix C calibration certificate content and in-page format (19)
Appendix D proofreading rod size deviation limit the amount of provisions (500mm ~ 1000mm) (21)
introduction
JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "common terminology and measurement
Definitions ", JJF 1059.1-2012" Evaluation and Expression of Uncertainty in Measurement "together constitute the support of the calibration code revision
Basic series of normative work.
The code revision, the main reference standard JB/T 10007-2012 "Great outside micrometer (measuring range
1000mm ~ 3000mm) "and GB/T 1216-2004" outside micrometer ", this specification replace JJF 1088-
2002 "outside micrometer (measuring range 500mm ~ 3000mm) calibration specification."
Compared with JJF 1088-2002, in addition to editorial changes, the main technical specification of the changes are as follows.
--- Name specification to "large outside micrometer calibration specification."
--- Large size outside micrometer overview has been modified.
--- Remove the "radial and axial movement of the micrometer screw swing" and "groove width and a width between" the two
index.
--- Increased by gantry measuring "return error indication table" approach jog.
--- Anvil surface and measuring the relative offsets micrometer screw measuring surface index has been modified.
--- Increase with large table outside micrometer anvil activity indicator measuring the force at the contact plane and spherical, and measure
Changes within their means giving provisions.
--- Surface roughness measuring surface according to the type of material, the shape of the surface can vary somewhat.
--- For measuring surface flatness index has been modified.
--- Indicators parallelism of two micrometer diameter measuring surface has been modified.
--- Indication error indicators micrometer head has been modified.
--- Large size outside micrometer indicators and calibration method error of indication has been modified.
--- Indicators proofreading amount Rod Size deviation has been modified.
--- Canceled proofing dipstick parallel index requirements.
--- Face of two parallel calibration method were refined.
--- The amount of block size micrometer indication when using error correction were perfect with GB recommended values of unity.
--- Re-measurement of Uncertainty about Indication Error assessed.
JJF 1088 of previously issued as follows.
JJF 1088-2002 "outside micrometer (measuring range 500mm ~ 3000mm) calibration standard"
JJG193-1987 micrometer (measuring range 500mm ~ 3000mm) (Trial)
Large outside micrometer calibration specification
1 Scope
This instruction applies to indexing is 0.01mm, respectively measuring range (500 ~ 1000) mm, (1000 ~
3000) mm large size micrometer diameter calibration.
2. References
This specification refers to the following documents.
JB/T 10007-2012 large outside micrometer (measuring range 1000mm ~ 3000mm)
GB/T 1216 outside micrometer
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments) applies to this specification.
3 Overview
Large outside micrometer screw vice principle is the use of two measuring foot rack between surfaces separated by distance measurement
External dimensions measuring instruments. Anvil can be changed or large size adjustable micrometer diameter shown in Figure 1, with a large table outside micrometer
Figure 2, the amount of proofreading rod in Figure 3.
Figure 1 anvil can be changed or large size adjustable outside micrometer
1- foot frame; 2- anvil; 3- anvil fastening bolts; 4- force measuring device; 5- differential cylinder; 6- fixed casing;
7- spindle locking device; 8- micrometer screw; 9- thermal insulation
......