HOME   Cart(3)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

GB/T 4703-2007 English PDF

GB/T 4703: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 4703-2007EnglishRFQ ASK 11 days [Need to translate] Capacitor voltage transformers Obsolete GB/T 4703-2007
GB/T 4703-2001English839 Add to Cart 6 days [Need to translate] Capacitor voltage transformers Obsolete GB/T 4703-2001
GB/T 4703-1984English639 Add to Cart 5 days [Need to translate] Capacitor voltage transformers Obsolete GB/T 4703-1984

PDF similar to GB/T 4703-2007


Standard similar to GB/T 4703-2007

GB/T 8286   GB 1094.1   GB 1094.11   GB/T 1094.7   GB/T 6451   GB/T 1094.101   

Basic data

Standard ID GB/T 4703-2007 (GB/T4703-2007)
Description (Translated English) Capacitor voltage transformers
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K41
Classification of International Standard 29.180
Word Count Estimation 62,676
Date of Issue 2007-12-03
Date of Implementation 2008-05-01
Older Standard (superseded by this standard) GB/T 4703-2001
Adopted Standard IEC 60044-5-2004, MOD
Regulation (derived from) Announcement of Newly Approved National Standards No. 12 of 2007 (Total No. 112); National Standards Bulletin 2013 No. 2
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard applies to the line and the ground connection between the new single-phase capacitor voltage transformers, the system voltage Um> 72. 5 kV, quite rate 15 Hz ~ 100 Hz. Them as measurement, control and protection equipment in providing low voltage. Capacitor voltage transformer can load Wave accessories for a carrier frequency of 30 kHz ~ 500 kH: Power Line Carrier (PLC) systems. The following three standards form the basis for this standard: GB 1207, concerning electromagnetic voltage transformer, GB/T 19749, for coupling capacitors and capacitive voltage divider, GB/T 7329, on Power Line Carrier (PLC) combined with the device. Measurement functions including measurements indicate that the measurement and billing.

GB/T 4703-2007: Capacitor voltage transformers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Capacitor voltage transformers ICS 29.180 K41 National Standards of People's Republic of China Replacing GB/T 4703-2001 Capacitor Voltage Transformer (IEC 60044-5.2004, Instrumenttransformers- Part 5. Capacitorvoltagetransformers, MOD) Posted 2007-12-03 2008-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅴ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 3.1 General definitions 2 3.2 Definition of capacitive voltage divider 6 3.3 is defined electromagnetic unit 8 3.4 Carrier is defined in Annex 8 4 General requirements 9 5 Conditions 9 5.1 Classification of environmental conditions 9 5.2 normal conditions of use 9 5.3 Special conditions 10 5.4 System Grounding 10 6 Rating 10 6.1 rated frequency standard value of 10 6.2 rated voltage standard value of 10 6.3 standard rated output value 11 6.4 rated voltage factor standard values 11 6.5 temperature rise limit 11 7 design requirements 12 7.1 Insulation requirements 12 7.2 Other insulation requirements 13 7.3 short-circuit capacity of 16 7.4 Ferroresonance 16 7.5 Electromagnetic emission requirements 17 7.6 the mechanical strength requirements 17 Sealing performance 7.7 capacitive voltage divider and electromagnetic unit 18 8 Test Category 18 8.1 Overview 18 8.2 Type tests 18 8.3 Routine tests 19 19 8.4 Special tests 8.5 Test sequence 1 or 2 units of 19 products 9 Type Test 21 9.1 Temperature Rise Test 21 9.2 frequency capacitance and tanδ measuring 21 9.3 Short Circuit Withstand Ability Test 22 9.4 Impact test 22 9.5 capacitor voltage transformer outdoor wet test 23 9.6 ferromagnetic resonance test 24 9.7 Accuracy test 24 25 9.8 Transient Response Test 9.9 Radio interference voltage test 27 10 Routine tests 28 Sealing performance test 10.1 impregnated liquid capacitive voltage divider 28 Measuring 10.2 frequency voltage withstand test and capacitance, tanδ and partial discharge 28 31 10.3 Inspection terminal markings Power frequency withstand voltage test 10.4 electromagnetic unit 31 10.5 ferromagnetic resonance test 31 10.6 Accuracy Test 32 10.7 impregnating liquid sealing performance test electromagnetic unit 33 11 special tests 33 11.1 pass over voltage measurement 33 35 11.2 Mechanical strength test 11.3 Determination of the temperature coefficient (TC) 36 Seal test designed 11.4 capacitor unit 36 12 flag capacitor unit 37 12.1 Overview 37 12.2 mark 37 13 terminal flag 37 13.1 Overview 37 13.2 mark 37 Supplemented with 14 measures the capacitor voltage transformer of claim 38 14.1 Accuracy class identity 38 Standard reference range of frequency 14.2 38 14.3 Standard accuracy class 38 14.4 voltage and phase error limits 38 14.5 Accuracy Test 39 15 protection supplementary capacitor voltage transformer of claim 39 15.1 Accuracy class identity 39 15.2 Standard reference frequency range 39 15.3 Standard accuracy class 39 15.4 voltage and phase error limits 39 15.5 Transient Response 40 Requirements 15.6 pairs for generating a residual voltage of the secondary winding 41 16 Nameplate 42 16.1 nameplate 42 16.2 A typical plate example 43 17 pairs of carrier attachment requirements 45 17.1 Overview 45 17.2 drainage coil and pressure limiting means 45 Type carrier attachment test 45 17.3 Routine tests 17.4 carrier annex 46 17.5 nameplate 46 Appendix A (informative) This standard reg number and IEC 60044-5.2004 47 reg number control Annex B (informative) This standard and IEC 60044-5.2004 technical differences and their reasons 48 Annex C (normative) capacitor voltage transformer circuit diagram illustrating 51 Appendix D (Informative Appendix) IEC 60044-5.2004 standard specifies the altitude correction factor 52 Appendix E (Informative Appendix) IEC 60044-5.2004 standard specifies the standard insulation level 53 High-frequency characteristics Annex F (normative) capacitor voltage transformer 54 Annex G (informative) Transient fault condition response capacitor voltage transformer 55 Figure 1 elevation of temperature correction factor 12 Figure 2 type test (Fig. 2a) and routine tests (Fig. 2b), test sequence flow chart 20 Transient Capacitor Voltage Transformer equivalent circuit of FIG. 3 in response to the test circuit diagram 26 Figure 4 series load 26 5 pure resistance 26 6 radio interference voltage measurement circuit 28 7 partial discharge test measuring circuit 29 8 Another partial discharge measurement test circuit 30 Figure 9 Example 30 balance test circuit Correction circuit 10 Example 30 11 with an equivalent circuit for the accuracy of the test level 1 CVT error illustrated example 33 Figure 12 is passed through the voltage measurement. the test circuit test arrangement and GIS 33 Figure 13 is passed through the voltage measurement. General test arrangement 34 Figure 14 is passed through the voltage measurement. test waveforms 35 15 single-phase transformer having a secondary winding 37 Figure 16 has two single-phase transformer secondary winding 37 Single-phase transformer 17 having two tapped secondary winding 37 Figure 18 has a residual voltage winding and two secondary windings of the single-phase transformer 38 19 accuracy class 0.2, 0.5 and 1.0 for the capacitor voltage transformer errors 39 Figure 20 Transient response of capacitor voltage transformer 40 21 typical plate example 44 Figure C. Capacitor voltage transformer circuit diagram illustrating 51 Figure C. 2 having a carrier attachment capacitor voltage transformer circuit diagram illustrating 51 Figure D. 1 external insulation altitude correction factor 52 Figure E. 1 standard insulation level 53 Table 1 rated ambient temperature category 9 Table 2 satisfy the accuracy and thermal performance requirements of the standard values of rated voltage factor 11 Table 3 winding temperature rise limit of 12 Table 4 standard insulation level 13 Table 5 partial discharge measurement voltage level and allow 14 Table 6 creepage distance 16 Table 7a Ferroresonance claim 17 Table 7b Ferroresonance claim 17 Table 8 passed over voltage limit 17 Table 9 Static withstand test load 18 Table 10 temperature rise test test voltage of 21 Load range Table 11 Accuracy Test 25 12 unit table, a stack and the overall test voltage capacitive divider 29 Table 13 Ferroresonance test 32 Table 14 Accuracy check point (example) 32 Table 15 way terminal end of a line of application of the test load 36 Table 16 measuring capacitor voltage transformer voltage and phase error limits 38 Table 17 protective capacitor voltage transformer voltage and phase error limits 40 Table 18 transient response level standard value of 41 Table 19 for generating a residual voltage of the capacitor voltage transformer secondary voltage rating of 41 Table 20 nameplate 42 Table 21 is equipped with a carrier annex capacitive voltage transformer nameplate sign additional item 46 Table A. A standard reg number and IEC 60044-5.2004 47 reg number control Table B. A standard and IEC 60044-5.2004 technical differences and the reasons 48

Foreword

This revised standard adopts IEC 60044-5.2004 "Transformers Part 5. Capacitor Voltage Transformer" (in English). This standard is based on IEC 60044-5.2004 redrafted. This chapter lists the standard and IEC 60044-5 article number in Appendix A. 2004 "Transformers Part 5. Capacitor Voltage Transformer" control list numbered clauses. Taking into account China's national conditions, in using IEC 60044-5.2004, the standard of this made some changes to the technical differences have been incorporated into the text In which they are involved and the terms of the margin of a single vertical line identification. These technical differences are given in Appendix B and their causes The list for reference. For ease of use, the standard IEC 60044-5.2004 also made the following editorial changes. a) according to GB/T 1.1-2000 requirements, and for writing the format has been modified; b) use a decimal point instead of a decimal comma ",". ","; c) the physical symbol, indicates subscript R rating and indicates the amount of transformer primary and secondary index P amount subscript S etc. They are replaced by lowercase letters (associated with our current standard uniform); d) Remove the IEC foreword; e) the normative references by the modified content has been adjusted, and the original IEC standard has a corresponding national standards or industry Replace herein are standard; f) the introductory phrase in Chapter 3 of GB/T 1.1-2000 requirements had been revised; g) Table 20 indicates the applicable "×" changes to "○"; h) deleted references. This standard replaces GB/T 4703-2001 "capacitor voltage transformers." The main changes compared to "Capacitive Voltage Transformer" This standard and GB/T 4703-2001 as follows. The main requirements and test a) will have a capacitive voltage divider directly into the text of this standard; b) rated output is divided into two categories, the output value greatly reduced; c) increasing the ferromagnetic resonance test in routine tests; d) The transient response requirements are divided into Level 3, Level 3 requirements higher than the original standard; e) increasing the transfer of over-voltage limit and testing; f) increased radio interference voltage requirements and tests; g) increase the special test category; h) repetitive frequency voltage withstand test voltage is increased from 75% to 80% of the specified value. This standard Appendices C and F are normative appendices, Appendix A, Appendix B, Appendix D, Appendix E and Appendix G is an informative annex. The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Standardization Technical Committee transformers (SAC/TC222) centralized. This standard is drafted by. Electric Power Research Institute in Xi'an capacitors, Shenyang Transformer Research Institute. Participated in the drafting of this standard. Xi'an Electric Power Capacitor Co., Ltd., the legendary Electric (Shenyang) Co., Ltd., Wuhan High Voltage RESEARCH Study Institute, Nissin Electric (Wuxi) Co., Ltd., Guilin Power Capacitor Factory, Shanghai MWB Transformer Co., Ltd., New Northeast Electric (Jinzhou) Power Capacitor Co., Ltd., Wuxi Huaneng Power Capacitor Co., Ltd., Tianjin Taylor Power Equipment Technology Co., Ltd., Jiangsu Branch fine cross Sensor Co., Ltd. Jiangsu source Hertz Transformer. The main drafters of this standard. Guo Tianxing, room sworn, cotton emperor, Wang Xiaoqi, Yang Yimin, Wang Zengwen, Liu Jing, PAN Hong-mei, Gu Jinsong, Yin Shi Ann, Deng tower, Zhang Jun, Liu Weihong, Sun Min, MAO Li-xin, Wei Zhaohui. This standard replaces the standards previously issued as follows. --- GB 4703-1984; GB/T 4703-2001. Capacitor Voltage Transformer

1 Scope

This standard applies to the new single-phase capacitor voltage transformer between the line and ground, the system voltage Um≥72.5kV, frequency 15Hz ~ 100Hz. They provide low-voltage measurement, control and protection devices. Capacitor voltage transformers can be loaded wave accessory for the carrier frequency of 30kHz ~ 500kHz Power Line Carrier (PLC) system. The following three criteria constituting the basis of this standard. --- GB 1207, related to electromagnetic voltage transformer; --- GB/T 19749, relating to the coupling capacitors and capacitive voltage divider; --- GB/T 7329, about the power line carrier (PLC) binding equipment. Measurement functions include measurements indicate that the measurement and billing. Note 1. Appendix C shows the capacitor voltage transformer circuit diagram showing examples of the applicable standards; Note 2. If the user needs, Um is 40.5kV capacitive voltage transformer can also be used in this standard.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 156 standard voltage (GB 156-2003, IEC 60038. 1983, IEC standardvoltages, NEQ) GB 311.1 insulation with high-voltage power transmission equipment (GB 311.1-1997, neqIEC 60071-1.1993) GB 1207-2006 electromagnetic voltage transformer (IEC 60044-2.2003, Instrumenttransformers-Part 2. Induc- tivevoltagetransformers, MOD) GB/T 2900.15 Electrotechnical terminology transformers, transformers, regulators and reactors (GB/T 2900.15-1997, neqIEC 60050 (421).1990, IEC 60050 (321). 1986) GB/T 2900.16 Electrotechnical terminology - Power capacitors (GB/T 2900.16-1996, neqIEC 60050 (436).1990) GB/T 2900.50 Electrotechnical terminology Generation, transmission and distribution of generic terms (GB/T 2900.50-1998, neqIEC 60050 (601). 1985) GB/T 2900.57 Electrotechnical terminology Generation, transmission and distribution operations (GB/T 2900.57-2002, eqv IEC 60050 (604). 1987) GB/T 4798 (series) electric and electronic products application environment conditions (idt, eqv or neqIEC 60721 series) GB/T 5585.1-2005 electrician with copper, aluminum and its alloy bus - Part 1. Copper and copper alloy bus GB/T 7329 Power Line Carrier binding device (GB/T 7329-1998, neqIEC 60481. 1974) GB/T 7354-2003 partial discharge measurements (IEC 60270.2000, IDT) GB/T 11021 heat-resistant electrical insulation classification (GB/T 11021-2007, IEC 60085.2004, IDT) GB/T 11023 sulfur hexafluoride gas high-voltage switchgear sealing test method GB/T 11604 high-voltage electrical equipment radio interference test method (GB/T 11604-1989, eqv IEC CISPR18-1. 1982, IEC CISPR18-2. 1986) GB/T 16927.1 High-voltage test techniques Part 1. General test requirements (GB/T 16927.1-1997, eqv IEC 60060-1. 1989)