HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

GB/T 22874-2008 English PDF

US$139.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 22874-2008: Single-faced and single-wall corrugated fibre board -- Determination of flat crush resistance
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 22874-2008English139 Add to Cart 3 days [Need to translate] Single-faced and single-wall corrugated fibre board -- Determination of flat crush resistance Valid GB/T 22874-2008

PDF similar to GB/T 22874-2008


Standard similar to GB/T 22874-2008

GB/T 24328.3   GB/T 27741   GB/T 31905   GB/T 22877   GB/T 22873   GB/T 22872   

Basic data

Standard ID GB/T 22874-2008 (GB/T22874-2008)
Description (Translated English) Single-faced and single-wall corrugated fibre board -- Determination of flat crush resistance
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Y30
Classification of International Standard 85-010
Word Count Estimation 6,633
Date of Issue 2008-12-30
Date of Implementation 2009-09-01
Quoted Standard GB/T 450; GB/T 10739
Adopted Standard ISO 3035-1982, MOD
Regulation (derived from) National Standard Approval Announcement 2008 No.25 (Total No.138)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the method for measuring the manufacturing of corrugated cardboard boxes with flat crush strength. This standard applies to single-sided and single- corrugated cardboard, does not apply to double corrugated cardboard.

GB/T 22874-2008: Single-faced and single-wall corrugated fibre board -- Determination of flat crush resistance


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Single-faced and single-wall corrugated fibreboard. Determination of flat crush resistance ICS 85-010 Y30 National Standards of People's Republic of China Determination and single-sided corrugated board flat crush resistance (ISO 3035. 1982, MOD) Posted 2008-12-30 2009-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This revised standard adopts ISO 3035. 1982 "and the single-sided corrugated board flat crush strength determination." This standard and ISO 3035. 1982 as compared to the main differences are as follows. --- International standards in Chapter 1, "scope" and Chapter 2, "Applications" merger of this standard in Chapter 1, "scope"; --- References to normative documents substituted with International Standard reference materials, and the ISO 3035 international standard referenced into with The corresponding national standards (Chapter 2 of this standard); --- The flat crush tester parallelism deviation is less than "1.1000" to "1.2000" (this standard 4.1); --- Increase the chart in Appendix A and single-sided corrugated board. Appendix A of this standard is a normative appendix. The standard proposed by China National Light Industry Council. This standard by the National Standardization Technical Committee of the paper industry. This standard was drafted. Exit Inspection and Quarantine Technology Center of Guangdong, China Pulp and Paper Research Institute, the National Quality Supervision, Inspection and paper center. The main drafters of this standard. red Zhou Ying, Guo Renhong. Determination and single-sided corrugated board flat crush resistance

1 Scope

This standard specifies the determination method of manufacturing a corrugated cardboard box flat crush strength. This standard applies to single-sided and corrugated board, does not apply to double corrugated cardboard.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 450 and take samples to an aspect of paper and paperboard samples, positive and negative determination (GB/T 450-2008, ISO 186. 2002, MOD) GB/T 10739 paper, paperboard and pulp sample processing and testing standard atmospheric conditions (GB/T 10739-2002, eqv ISO 187. 1990) Principle 3 Take a sample representative of the corrugated board, with compression tester consists of two parallel plates composed of a vertical surface of the specimen plus Pressure until the corrugated crushed so far, determine the maximum pressure per unit area of \u200b\u200bthe specimen subjected to kilopascals (kPa) represented.

4 Instrument

4.1 Flat pressure tester 4.1.1 by the motor drive pressure plate compression tester, the sample size should be larger than the size of the platen (4.2) to ensure that the sample does not exceed the platen Outside, and shall meet the following requirements. --- Parallelism deviation should be less than 1.2000; --- Lateral movement should not exceed 0.05mm. NOTE. You can use very fine sandpaper wrapped plate, and should be kept flatness and parallelism of the surface of the parcel. 4.1.2 If the tester has a fixed platen, another piece of plate relative motion in the vertical direction, the movable platen lifting speed Shall (12.5 ± 2.5) mm/min. 4.1.3 If the tester according to beam bending works only when the test result falls instruments span a range of 20% to 80%, only Such equipment can be measured. When the movable platen into contact with the sample, the applied pressure, speed should be (110 ± 23) N/s (priority) Or (67 ± 23) N/s. 4.2 CD-like device Can cut out a sample area of \u200b\u200bnot less than 50cm2 circular cut like a knife, the sample should be neat trimming and perpendicular to the corrugated board. Note. The general use area 64.5cm2 (diameter 90.6mm ± 0.5mm) and 100cm2 (diameter 112.8mm ± 0.5mm). When the flat crush resistance exceeding The instrument range, smaller sample (typically 32.2cm2) may be used.

5 Sampling

Sampling by GB/T 450 performed.

6 processing temperature and humidity

Sample Press GB/T 10739 temperature and humidity were treated.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 22874-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 22874-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 22874-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 22874-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information