GB/T 19666-2019English380 Add to Cart 0--3 minutes. Auto immediate delivery. General rules for flame retardant and fire resistant electric wires and cables or optical fiber cables GB/T 19666-2019 Valid GBT 19666-2019
GB/T 19666-2005English75 Add to Cart 0--3 minutes. Auto immediate delivery. Flame retardant and fire resistant wires and cables GB/T 19666-2005 Obsolete GBT 19666-2005


   
BASIC DATA
Standard ID GB/T 19666-2019 (GB/T19666-2019)
Description (Translated English) General rules for flame retardant and fire resistant electric wires and cables or optical fiber cables
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K13
Classification of International Standard 29.060.20
Word Count Estimation 22,217
Date of Issue 2019-12-10
Date of Implementation 2020-07-01
Drafting Organization Shanghai Cable Research Institute Co., Ltd., Shanghai National Cable Testing Center Co., Ltd., Sichuan Fire Research Institute of Emergency Management Department, East China Architectural Design and Research Institute Co., Ltd., Jiangsu Hengtong Power Cable Co., Ltd., Jiangsu Shangshang Cable Group Co., Ltd., Far East Cable Co., Ltd. , Zhejiang Wanma Co., Ltd., Guangzhou Nanyang Cable Co., Ltd., Jiangsu Zhongtian Technology Co., Ltd., Baosheng Technology Innovation Co., Ltd., Shanghai Capote Cable Material Factory Co., Ltd., Remote Cable Co., Ltd., Shanghai Huapu Cable Co., Ltd., Guangdong Xinyaguang Cable Industry Co., Ltd., Jinbei Electric Co., Ltd., Wuxi Jiangnan Cable Co., Ltd., Shanghai Pudong Wire and Cable (Group) Co., Ltd., Kunming Cable Group Co., Ltd., Shandong Hualing Cable Co., Ltd., China Quality Certification Center, Beijing Institute of Electrical Technology and Economics of Machinery Industry
Administrative Organization National Wire and Cable Standardization Technical Committee (SAC/TC 213)
Proposing organization China Electrical Appliance Industry Association
Issuing agency(ies) State Administration of Market Supervision and Administration, National Standardization Administration


GB/T 19666-2019: PDF in English (GBT 19666-2019)
GB/T 19666-2019
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 29.060.20
K 13
Replacing GB/T 19666-2005
General Rules for Flame Retardant and Fire Resistant
Electric Wires and Cables or Optical Fiber Cables
ISSUED ON: DECEMBER 10, 2019
IMPLEMENTED ON: JULY 01, 2020
Issued by: State Administration for Market Regulation;
Standardization Administration of the People’s Republic of China.
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative References ... 5
3 Terms and Definitions ... 6
4 General ... 7
5 Product Model ... 7
5.1 Code and combination of combustion characteristics ... 7
5.2 Composition of product model ... 9
5.3 Expression of product ... 10
6 Requirements for Combustion Properties ... 10
6.1 Flame retardance ... 10
6.2 Fire resistance ... 11
6.3 Halogen free performance ... 12
6.4 Low smoke performance ... 13
6.5 Low toxicity performance ... 13
7 Technical Requirements ... 14
7.1 Flame-retardant wire and cable or optical fiber cable series ... 14
7.2 Fire-resistant wire and cable or optical fiber cable series ... 15
8 Acceptance Rules ... 16
Appendix A (Normative) Water Spray Test Method ... 17
Appendix B (Normative) Water Spray Test Method ... 19
Appendix C (Normative) Toxicity Indicator Test Method ... 21
Bibliography ... 27
General Rules for Flame Retardant and Fire Resistant
Electric Wires and Cables or Optical Fiber Cables
1 Scope
This Standard specifies the code, technical requirements, test methods and acceptance rules for
the combustion characteristics of flame-retardant and fire-resistant wires, cables or optical fiber
cables, including halogen-free, low-smoke, low-toxicity, flame-retardant and fire-resistant
combustion characteristics.
This Standard applies to halogen-containing, halogen-free, low-smoke, low-toxic flame-
retardant and fire-resistant wire and cable or optical fiber cable products.
2 Normative References
The following documents are essential to the application of this document. For the dated
documents, only the versions with the dates indicated are applicable to this document; for the
undated documents, only the latest version (including all the amendments) is applicable to this
document.
GB/T 4208-2017 Degrees of Protection Provided by Enclosure (IP Code)
GB/T 17650.1 Test on Gases Evolved During Combustion of Materials from Cables or
Optical Fiber Cables-Part 1: Determination of the Halogen Acid Gas Content
GB/T 17650.2 Test on Gases Evolved During Combustion of Materials from Cables or
Optical Fiber Cables - Part 2: Determination of Acidity (by pH Measurement) and
Conductivity
GB/T 17651.2 Measurement of Smoke Density of Cables or Optical Fiber Cables Burning
under Defined Conditions - Part 2: Test Procedure and Requirements
GB/T 18380.12 Test on Electric and Optical Fiber Cables under Fire Conditions - Part 12:
Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Procedure for
1kW Pre-Mixed Flame
GB/T 18380.13 Tests on Electric and Optical Fiber Cables under Fire Conditions - Part 13:
Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Procedure for
Determination of Flaming Droplets/Particles
GB/T 18380.22 Tests on Electric and Optical Fiber Cables under Fire Conditions - Part 22:
Test for Vertical Flame Propagation for a Single Small Insulated Wire or Cable - Procedure
for Diffusion Flame
GB/T 18380.33 Tests on Electric and Optical Fiber Cables under Fire Conditions - Part 33:
Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category
GB/T 18380.34 Tests on Electric and Optical Fiber Cables under Fire Conditions - Part 34:
Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category
GB/T 18380.35 Tests on Electric and Optical Fiber Cables under Fire Conditions - Part 35:
Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category
GB/T 18380.36 Tests on Electric and Optical Fibre Cables under Fire Conditions - Part 36:
Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category
GB/T 19216.21 Tests for Electric Cables under Fire Conditions - Circuit Integrity - Part
21: Procedures and Requirements - Cables of Rated Voltage up to and including 0.6/1.0kv
GB/T 19216.23 Tests for Electric Cables under Fire Conditions - Circuit Integrity - Part
23: Procedures and Requirements - Electric Data Cables
GB/T 19216.25 Tests for Electric Cables under Fire Conditions - Circuit Integrity - Part
25: Procedures and Requirements - Optical Fiber Cables
IEC 60331-1 Tests for Electric Cables under Fire Conditions – Circuit Integrity – Part 1:
Test Method for Fire with Shock at a Temperature of at least 830°C for Cables of Rated
Voltage up to and including 0.6/1.0kV and with an Overall Diameter Exceeding 20mm
IEC 60331-2 Tests for Electric Cables under Fire Conditions – Circuit Integrity – Part 2:
Test Method for Fire with Shock at a Temperature of at least 830°C for Cables of Rated
Voltage up to and including 0.6/1.0kV and with an Overall Diameter not Exceeding 20mm
IEC 60684-2:2011 Flexible Insulting Sleeving – Part 2: Methods of Test
IEC 60754-3 Test on Gases Evolved during Combustion of Materials from Cables – Part
3: Measurement of Low Level of Halogen Content by Ion Chromatography
3 Terms and Definitions
For the purposes of this Document, the following terms and definitions apply.
3.1 Flame retardance
The characteristics that, when the sample is burned under specified conditions, the spread of
flame on the sample is only within a limited range after the ignition source is removed, and it
has the capability of preventing or delaying the occurrence or spread of flame.
3.2 Fire resistance
The characteristic that a specimen can continue to operate under specified conditions when it
is burned under specified ignition source and time.
3.3 Halogen free
The characteristic that the halogen (fluorine, chlorine, bromine, iodine) content of the gas
released during combustion is all less than or equal to 1.0 mg/g.
3.4 Low smoke
The characteristic that the concentration of smoke produced by burning does not reduce
visibility (light transmittance) to the extent that it affects escape.
3.5 Low toxicity
The characteristic that the toxic effect and concentration of the toxic fumes produced during
combustion shall not cause the living organisms to die within 30min.
4 General
The combustion characteristics of flame-retardant and fire-resistant wire and cable or optical
fiber cable products shall comply with the requirements of this Standard; and other properties
other than combustion characteristics shall comply with the requirements of the corresponding
product standards.
Wire and cable or optical fiber cable products may reduce their original basic characteristics
while achieving their flame retardance and/or fire resistance purposes, or cause some original
test methods to be inapplicable. All parties using this Standard shall discuss or negotiate a
suitable solution to ensure that the wire and cable or optical fiber cable products achieve the
purpose of flame retardance and/or fire resistance while ensuring safety and reliability during
use. On the premise of without reducing the safety and reliability during use, the corresponding
technical indicators or test methods can be adjusted appropriately.
5 Product Model
5.1 Code and combination of combustion characteristics
5.1.1 Code of combustion characteristics
Halogen-free, low-smoke, flame-retardant wire and cable or optical fiber cable sheathing and /
or insulation can select halogen-free, low-smoke, flame-retardant materials; and the
performance shall be in line with the requirements of relevant product standards. Filling,
wrapping or flame-retardant reinforcement layer and other auxiliary materials shall be selected
appropriately, so that the product meets the requirements of the corresponding flame retardant
category.
The non-metallic materials used by the halogen-free, low-smoke, flame-retardant wire and
cable or optical fiber cable shall meet the requirements of halogen-free performance. The
acidity and electrical conductivity of the released gas, halogen acid gas release or the halogen
content during the combustion of the non-metallic materials shall meet the requirements of 6.3;
the smoke density (minimum transmittance) of the finished products shall meet the
requirements of 6.4.
7.1.3 Halogen-free, low-smoke, low-toxicity flame-retardant wire and cable or optical
fiber cable
The non-metallic materials used by the halogen-free, low smoke and low toxicity flame-
retardant wire and cable or optical fiber cable shall have very little halogen content; the
combustion products are of lower corrosion and toxicity; the combustion products have lower
smoke (higher transmittance). It can be divided into the following categories according to the
flame-retardant characteristics:
--- halogen-free, low smoke, low toxicity, single-piece flame-retardant WDUZ, the single-
piece flame retardance shall meet the requ......