HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (12 Oct 2024)

GB/T 19367-2022 related PDF English

GB/T 19367-2022 (GB/T19367-2022, GBT 19367-2022, GBT19367-2022) & related versions
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)See DetailStatusSimilar PDF
GB/T 19367-2022English155 Add to Cart 0-9 seconds. Auto delivery. Determination of dimensions of wood-based panels GB/T 19367-2022 Valid GBT 19367-2022
GB/T 19367-2009English105 Add to Cart 0-9 seconds. Auto delivery. Wood-based panels -- Determination of dimensions of panels GB/T 19367-2009 Obsolete GBT 19367-2009
GB/T 19367.1-2003English319 Add to Cart 3 days Wood-based panels -- Determination of thickness, width and length of boards GB/T 19367.1-2003 Obsolete GBT 19367.1-2003
Buy with any currencies (Euro, JPY, KRW...): GB/T 19367-2022    Preview this PDF: GB/T 19367-2022



GB/T 19367-2022: PDF in English (GBT 19367-2022)
GB/T 19367-2022 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 79.060.01 CCS B 70 Replacing GB/T 19367-2009 Determination of dimensions of wood-based panels (ISO 9426:2003, Wood-based panels - Determination of dimensions of panels, MOD) ISSUED ON: DECEMBER 30, 2022 IMPLEMENTED ON: JULY 01, 2023 Issued by: State Administration for Market Regulation; National Standardization Administration. Table of Contents Foreword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Terms and definitions ... 5 4 Determination methods ... 6 5 Result expression ... 9 6 Test report ... 10 Appendix A (Informative) Comparisons of structure numbers between this document and ISO 9426:2003 ... 11 Appendix B (Informative) List of technical differences between this document and ISO 9426:2003 and their reasons ... 12 Foreword This document is drafted in accordance with the provisions of GB/T 1.1-2020 "Directives for standardization - Part 1: Rules for the structure and drafting of standardizing documents". This document replaces GB/T 19367-2009 "Determination of dimensions of wood- based panels". Compared with GB/T 19367-2009, in addition to structural adjustments and editorial changes, the main technical changes are as follows: a) ADD terms and definitions (see Chapter 3); b) DELETE the principles, sampling, moisture content and balance processing of the plate during measurement (see Chapters 3, 4, 5, 6 of the 2009 edition); c) ADD the diagonal method for squareness determination (see 4.4.2); d) CHANGE the length measurement position (see 4.2; 8.2 of the 2009 edition); e) CHANGE the flatness determination (see 4.6; 8.5 of the 2009 edition); f) CHANGE the thickness accuracy requirements (see 5.2; 9.1 of the 2009 edition). This document modifies and adopts ISO 9426:2003 "Wood-based panels - Determination of dimensions of panels". Compared with ISO 9426:2003, this document has many structural adjustments. See Appendix A for a list of structure number comparisons between the two documents. Compared with ISO 9426:2003, this document has many technical differences. The involved clauses are marked with a vertical single line (│) in the outer margin of the page. A list of these technical differences and their causes is provided in Appendix B. The following editorial changes have been made to this document: a) In order to coordinate with the existing standards, CHANGE the name of the standard into "Determination of dimensions of wood-based panels"; b) ADD note to Figure 3; c) ADD informative appendix A and appendix B. Please note that some content in this document may be subject to patents. The publisher of this document assumes no responsibility for identifying patents. This document was proposed by the State Forestry and Grassland Administration. Determination of dimensions of wood-based panels 1 Scope This document describes methods for the determination of length, width, thickness, squareness, edge straightness, flatness of wood-based panels. This document is applicable to the dimensional determination of wood-based panels. 2 Normative references The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, for dated reference documents, only the version corresponding to the date applies to this document; for undated reference documents, the latest version (including all amendments) applies to this document. JB/T 12202-2015 Wedge feeler gauge 3 Terms and definitions The following terms and definitions apply to this document. 3.1 Squareness The degree to which the distance between the edge of the panel and the edge of the right angle (δ1, see Figure 1), or the four corners of the rectangular wood-based panel form precise right angles. the panel (see Figure 1). Then measure with one arm against the other side of the corner of the panel. The results are expressed as the ratio of the distance to the arm length of the mechanical square, in millimeters per meter (mm/m). Follow the same method as above for other angles; take the maximum value. 4.4.2 Method 2 Use a steel tape measure (4.1.2), to measure the two diagonal lengths and opposite side lengths of the panel, accurate to 1 mm. Calculate the diagonal difference and opposite side difference, respectively. The results are expressed as diagonal difference and opposite side difference, accurate to 1 mm. 4.5 Determination of edge straightness Use a steel ruler (4.1.5) close to the edge of a panel, OR straighten a metal wire (4.1.6) which is placed on two adjacent corners of the panel. According to the measurement range, choose a steel ruler, feeler gauge (4.1.7), wedge feeler gauge (4.1.8) or vernier caliper (4.1.3), to measure the maximum distance between the steel ruler or straightened metal wire and the edge of the panel. The result is expressed as the ratio of the maximum distance to the length of the panel edge, in millimeters per meters (mm/m). Other panel edges are measured in the same way as above. Note: If the length of the edge of the panel is less than 1000 mm, use a steel ruler; if the length is greater than 1000 mm, use a metal wire. 4.6 Determination of flatness Place the panel on a horizontal surface without any external force. Measure the distance between the entire surface of the tested panel and the straightened metal wire. Find the surface distance between the metal wire and the maximum deformation point of the panel. Use a steel ruler (4.1.5) to make measurement. The result is expressed as the ratio of the measured value to the diagonal of the panel, in millimeters per meter (mm/m). 5 Result expression 5.1 Length and width For each tested panel, calculate the arithmetic mean of the measured values representing the length and width respectively, accurate to 1 mm. 5.2 Thickness For each tested panel, calculate the arithmetic mean of each measurement value, accurate to 0.01 mm. 5.3 Squareness Method 1: The result is the maximum measured value of the deviation between the edge of the square and the edge of the panel, expressed in millimeters per meter of length, accurate to 0.5 mm/m. Method 2: The result is expressed as diagonal difference and opposite side difference, accurate to 1 mm. 5.4 Edge straightness The result is the maximum spacing divided by the length of that side, expressed in millimeters per meter (mm/m). The width and length of the panel are expressed separately. 5.5 Flatness The results are expressed as the ratio of the maximum deformation value to the diagonal of the panel, expressed in millimeters per meter (mm/m). 6 Test report The test report shall contain the following information: - Name and address of the testing laboratory; - Sampling reports according to relevant provisions of individual product standards for various wood-based panels; - Standards implemented for testing; - Date of test report; - Type, format size, thickness of wood-based panels; - Relevant product description; - If necessary, description of the surface treatment status; - The use of special instruments within the scope of this document as permitted under various possible circumstances; - Expression of test results using Chapter 5; - All inconsistencies with this document. ......

BASIC DATA
Standard ID GB/T 19367-2022 (GB/T19367-2022)
Description (Translated English) Determination of dimensions of wood-based panels
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard B70
Classification of International Standard 79.060.01
Word Count Estimation 10,137
Date of Issue 2022-12-30
Date of Implementation 2023-07-01
Older Standard (superseded by this standard) GB/T 19367-2009
Drafting Organization Wood Industry Research Institute of Chinese Academy of Forestry, Huzhou Inspection and Testing Center, Suzhou Product Quality Supervision and Inspection Institute, Mahogany Fang Furnishing Technology (Huzhou) Co., Ltd., Holy Elephant Group Co., Ltd., Dehua Rabbit Baby Decoration New Material Co., Ltd. , Zhaoqing Yaodonghua Decoration Material Technology Co., Ltd., Zhejiang Academy of Forestry Sciences, Zhejiang Shenghua Yunfeng New Material Co., Ltd., Jiangxi Inspection and Certification General Institute of Industrial Products Inspection and Testing Institute, Nanjing Forestry University, Shanghai Timber Industry Research Institute Co., Ltd., Shanghai Quality Supervision and Inspection Technology Research Institute, Changzhou Inspection and Testing Standard Certification Institute, Quzhou Fangyuanlin Product Inspection and Testing Co., Ltd., Zhaoqing Modern Zhumei Home Furnishing Co., Ltd., Shouguang Luli Wood Industry Co., Ltd., Sophia Home Furnishing Hubei Co., Ltd., Guangxi Zhuang
Administrative Organization National Wood-based Panel Standardization Technical Committee (SAC/TC 198)
Proposing organization State Administration for Market Regulation, National Standardization Management Committee