GA 999-2012: Test method for verifying field performance of smoke management system. Hot smoke test

GA 999: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GA 999-2012English879 Add to Cart 4 days [Need to translate] Test method for verifying field performance of smoke management system. Hot smoke test GA 999-2012
GA/T 999-2012English879 Add to Cart 5 days [Need to translate] Test method for verifying field performance of smoke management system-Hot smoke test Obsolete GA/T 999-2012

PDF similar to GA 999-2012


Standard similar to GA 999-2012

GB 4351   GA 602   GB 4066.2   

Basic data

Standard ID GA 999-2012 (GA999-2012)
Description (Translated English) Test method for verifying field performance of smoke management system. Hot smoke test
Sector / Industry Public Security (Police) Industry Standard
Classification of Chinese Standard C84
Classification of International Standard 13.220.01
Word Count Estimation 22,253
Quoted Standard GB 2626-2006; GB/T 2903-1998; GB/T 5907; GB/T 14107; GB 50019-2003
Adopted Standard AS 4391-1999��NEQ
Regulation (derived from) Smoke-proof system performance on-site verification hot smoke test method industry standard release
Issuing agency(ies) Ministry of Public Security
Summary This standard specifies test equipment, test procedures and safety requirements required for the construction of smoke control systems using hot smoke test methods without destroying the building structure and internal facilities and equipment, as well as

GA/T 999-2012: Test method for verifying field performance of smoke management system-Hot smoke test


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method for verifying field performance of smoke management system-Hot smoke test ICS 13.220.01 C84 People's Republic of China Public Security Industry Standards Smoke evacuation system performance field-proven method Hot smoke test method Hotsmoketest Issued on. 2012-06-19 2012-08-01 implementation People's Republic of China Ministry of Public Security

Table of Contents

Introduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 test apparatus 2 5 5 test procedure 6 Test personnel and facilities security 8 7 data records 9 8 Test preparation and test reports 10 Appendix A (normative) flue gas temperature and the smoke plume bottom layer at the interface and volume flow 12

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard reference to Australian Standards AS4391-1999 "smoke control systems Hot smoke test" (in English). This standard was proposed by the Ministry of Public Security Fire Department. This standard by the National Standardization Technical Committee on Fire Building Fire Safety Engineering at the Technical Committee (SAC/TC113/SC13) Centralized. This standard is drafted by. Ministry of Public Security of Sichuan Fire Research Institute. Participated in the drafting of this standard. Sichuan Province Public Security Fire Department, Ministry of Public Security Fire Department. The main drafters of this standard. a Xie Yuan, Zhang Xiaoming, Yang, Lu Guojian, Hu Zhong, Li Yue, Hu Rui.

Introduction

Based on the outcome of the reference standard in fire inspection of construction projects studied achieved in the field of foreign advanced standards, to prevent discharge Smoke system design, construction and management personnel to provide on-site evaluation of a smoke control system performance of hot smoke test methods can not test site Damage under the premise of the performance of smoke control system on-site testing. Objective hot smoke tests in the construction of smoke control system debugging process, flue gas generated by quantitative tests to examine the source of fire fire conditions Smoke control capability under smoke control system. Test combustion by ethanol pool fire heat plume colorless, non-toxic, with a visible tracer smoke Gas injection thermal plume, the flow characteristics of hot plume demo and start smoke control system, performance evaluation whether the smoke control system can meet the requirements. Smoke evacuation system performance field-proven method Hot smoke test method

1 Scope

This standard specifies the conditions under no structural damage and internal facilities, equipment, test method using hot smoke test smoke control system architecture The required test equipment, test procedures and security requirements, and produce smoke and quantitatively determine the size of the fire hot smoke test methods. This standard applies to hot smoke test in a special spatial structure, smoke control system design implementation of complex buildings, such as. the atrium, factories, cargo Other staff positions, department stores, shopping centers, office buildings and sports complex and entertainment centers and other crowded public buildings, tunnels, subways, car Station, airport and other transportation hubs buildings and large underground construction. Hot smoke test data can also be used to verify the smoke flow simulation software.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 2626-2006 respirator self-absorption filter anti-particulate respirators GB/T 2903-1998 Copper - copper-nickel (constantan) thermocouple wire GB/T 5907 fire first part basic terms GB/T 14107 Fire basic terms of the second part GB 50019-2003 heating, ventilation and air conditioning design

3 Terms and Definitions

GB/T 5907 and GB/T 14107 and defined by the following terms and definitions apply to this document. 3.1 Fuming means smokegenerator A way to generate quantitative volumetric flow of flue gas, comprising fuming cake into smoke and smoke leading source means two parts, fuming source, hair Chimney and smoke pot and other types. 3.2 Test fire source testfire Test test for the source of fire smoke control system, the heat release power is controlled in size without destroying the buildings and facilities and equipment Within the range. 3.3 Tracer smoke tracersmoke Fuming smoke particles generated by smoldering source, into ethanol burning hot smoke plume, the plume show flow characteristics.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GA 999-2012_English be delivered?

Answer: Upon your order, we will start to translate GA 999-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GA 999-2012_English with my colleagues?

Answer: Yes. The purchased PDF of GA 999-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GA 999-2012?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GA 999-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.