HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

YY/T 0643-2008 English PDF

US$374.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY/T 0643-2008: Methods of meeasuring the performance of ultrasonic pulse-echo diagnostic equipment
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 0643-2008English374 Add to Cart 3 days [Need to translate] Methods of meeasuring the performance of ultrasonic pulse-echo diagnostic equipment Valid YY/T 0643-2008

PDF similar to YY/T 0643-2008


Standard similar to YY/T 0643-2008

YY/T 0593   YY 0592   YY/T 0644   YY 0599   YY/T 0642   

Basic data

Standard ID YY/T 0643-2008 (YY/T0643-2008)
Description (Translated English) Methods of meeasuring the performance of ultrasonic pulse-echo diagnostic equipment
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C41
Classification of International Standard 11.040.50; 17.140.50
Word Count Estimation 19,142
Date of Issue 2008-04-25
Date of Implementation 2009-06-01
Adopted Standard IEC/TR 60854-1986, IDT
Regulation (derived from) SFDA [2008] No. 192
Issuing agency(ies) State Food and Drug Administration
Summary This standard specifies the description of measuring pulse-echo medical diagnostic system performance parameters, and gives test methods. This standard applies to 0. 5MHz ~ 25MHz ultrasonic frequency range using a single array element transducer ultrasound diagnostic equipment. This standard does not apply to Doppler ultrasound systems.

YY/T 0643-2008: Methods of meeasuring the performance of ultrasonic pulse-echo diagnostic equipment


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods of meeasuring the performance of ultrasonic pulse-echo diagnostic equipment ICS 11.040.50; 170.140.50 C41 Medical industry standards People's Republic of China YY/T 0643-2008/IEC /TR60854. 1986 Ultrasonic pulse echo diagnostic device performance test methods (IEC /T R60854. 1986, IDT) Posted 2008-04-25 2009-06-01 implementation State Food and Drug Administration issued

Foreword

This standard is equivalent to using IEC /T R60854. 1986 "pulse-echo ultrasound diagnostic device performance test methods) (in English). The original text of this standard the "Technical Report" to the "standard", and made a very small number of editorial changes do not affect the degree of consistency. This standard Annex A, Annex B, Annex C is informative appendices. This standard by the National Standardization Technical Committee medical ultrasound equipment. This standard was drafted. medical ultrasound equipment Wuhan National Quality Supervision and Inspection Center. The main drafters of this standard. white German study. YY/T 0643-2008/IEC /TR60854. 1986 Ultrasonic pulse echo diagnostic device performance test methods

1 Scope and purpose

1.1 Scope This standard defines the pulse-echo measurement described in medical diagnostic system performance parameters, and gives the test methods. This standard applies to single-element transducer array of ultrasonic diagnostic equipment in the ultrasonic frequency range 0.5MHz ~ 25MHz. This standard does not apply to ultrasound systems. 1.2 Purpose It provides general acceptable basis for the measurement and reporting of the entire diagnostic system main performance parameters, especially for similar diagnostic applications without Between manufacturers of similar devices to provide the same basis for comparison, select the specified performance parameters and the corresponding measurement method. Furthermore, the purpose of To obtain a set of measurements and results from the application of the recommended method provided useful basis for predicting the device performance in a particular diagnostic applications. In order to be able to generally applicable, in a specified process without using expensive and common equipment. When the basic system has about a specific diagnosis system When the member (such as a transducer) a variety of optional, when applicable requirements of this standard will each option as a separate system. The main part of the standard consists of six terms, namely to specify a specific system performance parameter (or a group of related articles in each Parameters) and give the appropriate measurement method. The necessary data and measurement methods, principles and related equipment (applies to two or more terms) is given in the Appendix. Measuring the acoustic output of diagnostic equipment have been proposed in other publications, and therefore not specified in this standard.

2 Terms and definitions

The following terms and definitions apply to this standard. 2.1 Made of a specific material capable of electrical energy into mechanical energy but also mechanical energy into electrical energy element. 2.2 Design of the input signal at the output of the desired characteristics of the output signals received from the system and provide a signal to another device of the system. Head of Prior to the actual applications, the transducer this term represents the complete mechanical assemblies, including the transducer element and the damping of mechanical and electronic And matching means. 2.3 The transducer in the water, from the surface of the transducer element to the left from the transducer beam axial direction of the last one of the most sound pressure Great value distance between locations. For a circular plane without any means focusing transducer element, standard working distance of about equal Rao 2/λ, which Λ is the medium in the water and the operating frequency corresponding to the acoustic wavelength, Rao is the transducer element metallized area of a circle radius. 2.4 At a distance of more than the standard working distance of the ultrasound beam, the straight line connecting the measured spatial-peak amplitude of the sound pressure points (in accordance with the rules of the regression calculation). For a non-focused transducer emitting acoustic beam must be doubled to twice the standard within the scope of the working distance at equal intervals to select these points. For focused transducer (status unknown or focusing transducers) must be standard operating distance on both sides of the point (but no more than two of the distance Fold) in the lower lobe level at least 10dB maximum sound pressure amplitude than the center of the beam area next to any beam measured at equal intervals to select these points. YY/T 0643-2008/IEC /TR60854. 1986

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 0643-2008_English be delivered?

Answer: Upon your order, we will start to translate YY/T 0643-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 0643-2008_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0643-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.