HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

YY 0304-2023 English PDF

US$279.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY 0304-2023: Plasma sprayed hydroxyapatite coated titanium dental implant
Status: Valid

YY 0304: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY 0304-2023English279 Add to Cart 3 days [Need to translate] Plasma sprayed hydroxyapatite coated titanium dental implant Valid YY 0304-2023
YY 0304-2009English110 Add to Cart 0--9 seconds. Auto-delivery Plasma sprayed hydroxyapatite coated-titanium dental implant Valid YY 0304-2009
YY 0304-1998English639 Add to Cart 5 days [Need to translate] Plasma sprayed hydroxyapatite coated titanium dental implant Obsolete YY 0304-1998

PDF similar to YY 0304-2023


Standard similar to YY 0304-2023

YY 0315   YY 0271.2   YY 0270.1   YY/T 0302.2   YY 0300   

Basic data

Standard ID YY 0304-2023 (YY0304-2023)
Description (Translated English) Plasma sprayed hydroxyapatite coated titanium dental implant
Sector / Industry Medical Device & Pharmaceutical Industry Standard
Classification of Chinese Standard C33
Classification of International Standard 11.060.10
Word Count Estimation 14,172
Date of Issue 2023-09-05
Date of Implementation 2026-09-15
Older Standard (superseded by this standard) YY 0304-2009
Issuing agency(ies) State Drug Administration
Summary This standard specifies the technical requirements and test methods for plasma sprayed hydroxyapatite coating-titanium-based dental implants. This standard applies to plasma sprayed hydroxyapatite coating-titanium-based dental implants made of forged titanium or titanium alloy materials as the base material.

YY 0304-2023: Plasma sprayed hydroxyapatite coated titanium dental implant

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 11.060.10 CCSC33 Pharmaceutical Industry Standards of the People's Republic of China Replaces YY 0304-2009 Plasma sprayed hydroxyapatite coating Titanium abutment dental implants Published on 2023-09-05 Implemented on 2026-09-15 Released by the State Drug Administration

Table of contents

Preface III Introduction IV 1 Scope 1 2 Normative reference documents 1 3 Terms and Definitions 1 4 Requirements 2 5 Test method 4 Appendix A (informative) Sample preparation method 7 Reference 8

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. This document replaces YY 0304-2009 "Plasma Sprayed Hydroxyapatite Coated Titanium Dental Implants" and is consistent with YY 0304-2009 In addition to structural adjustments and editorial changes, the main technical changes are as follows. a) "Plasma sprayed hydroxyapatite coating", "Plasma sprayed hydroxyapatite coating-titanium-based dental implant", "Endosseous dental implant" have been changed. Definitions of "implant" and "crystallinity" (see 3.2, 3.3, 3.4 and 3.6,.2009 edition of 3.2, 3.3, 3.4 and 3.6); b) The type and structure of dental implants in the requirements are deleted (see 4.1 of the.2009 edition), and the "geometric dimensions of the dental implant body are precisely "degree" has been adjusted according to the existing technical conditions (see 4.1.1, 4.2.1, 4.2.2 and 4.2.3 of the.2009 version); c) Change “dimensions and tolerances of important connection parts” to “fitting of dental implants and implant abutments” (see 4.1.4,.2009 edition 4.2.6); d) Change "HA content and crystallinity in coating" to "crystallinity" (see 4.2.2.1.1, 4.3.2.1.1 of the.2009 version); e) Added “other crystalline phases” (see 4.2.2.2); f) The starting value of the range of "calcium to phosphorus atomic ratio" is changed from 1.66 to 1.61 (see 4.2.2.1.3, 4.3.2.1.3 of the.2009 version); g) Added “Micromorphology of HA coating” (see 4.2.2.3); h) Added "torsion resistance" and "fastening performance" under "mechanical properties" (see 4.2.5.1, 4.2.5.2); i) Added “bacterial endotoxin” (see 4.4); j) The content related to biological evaluation has been deleted, and the expression of biocompatibility has been moved to the introduction (see Introduction, 4.4 of the.2009 version); k) Relevant content on signs, labels, packaging, transportation, and storage has been deleted (see Chapter 6 of the.2009 edition). Please note that some content in this document may be subject to patents. The publisher of this document assumes no responsibility for identifying patents. This document is proposed by the National Medical Products Administration. This document is under the jurisdiction of the National Standardization Technical Committee for Dental Materials and Equipment (SAC/TC99). This document was first published in October.1998, revised for the first time in.2009, and this is the second revision.

Introduction

This document does not include qualitative and quantitative test methods used to demonstrate that materials do not present unacceptable biological risks, such as evaluating biological For risks, please refer to GB/T 16886.1 and YY/T 0268. Plasma sprayed hydroxyapatite coating Titanium abutment dental implants

1 Scope

This document specifies the technical requirements and test methods for plasma sprayed hydroxyapatite-coated titanium-based dental implants. This document is applicable to plasma sprayed hydroxyapatite coated titanium abutment dental implants made of forged titanium or titanium alloy materials as the base material. Implants.

2 Normative reference documents

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document. GB/T 1031-2009 Product Geometric Specification (GPS) Surface roughness parameters and numerical values using surface structure profile method GB/T 13810-2017 Titanium and titanium alloy processed materials for surgical implants GB/T 23101.3 Hydroxyapatite for surgical implants Part 3.Chemical analysis and characterization of crystallinity and phase purity GB/T 23101.4 Hydroxyapatite for surgical implants Part 4.Determination of coating bond strength YY 0315 Titanium and titanium alloy dental implants YY/T 0521 Dynamic fatigue test of intraosseous dental implants in dentistry YY/T 0988.14-2016 Surgical implant coatings Part 14.Stereological evaluation method of porous coatings ISO /T S13498 Dentistry-Torsion measurement of endosteal dental implant body and connecting parts Pharmacopoeia of the People's Republic of China 2020 Edition Four Parts

3 Terms and definitions

The following terms and definitions as defined in YY 0315 apply to this document. 3.1 Plasma sprayingplasmaspraying One type of thermal spraying process uses a non-transfer arc as a heat source to ionize the gas, thereby producing a temperature of up to 10,000°C or more. The high temperature causes the spray material powder fed into the plasma flame through the spray gun to melt or surface-melt and spray it onto the surface of the substrate at high speed to form a coating. method. 3.2 Using plasma spraying method to spray hydroxyapatite powder, the hydroxyapatite formed on the surface of metal such as titanium or titanium alloy matrix (HA) thin layer. 3.3 plant A medical device surgically implanted into the jaw bone to secure and support dentures. Titanium abutment dental implant base is processed from titanium or titanium alloy

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY 0304-2023_English be delivered?

Answer: Upon your order, we will start to translate YY 0304-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY 0304-2023_English with my colleagues?

Answer: Yes. The purchased PDF of YY 0304-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YY 0304-2023?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY 0304-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.