US$189.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 281.17-2011: Methods for chemical analysis of cobalt. Part 17: Determination of aluminum, manganese, nickel, copper zinc, cadmium, tin, antimony, lead and bismuth content. Inductively coupled plasma mass spectrometry Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
YS/T 281.17-2011 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
Methods for chemical analysis of cobalt. Part 17: Determination of aluminum, manganese, nickel, copper zinc, cadmium, tin, antimony, lead and bismuth content. Inductively coupled plasma mass spectrometry
| Valid |
YS/T 281.17-2011
|
PDF similar to YS/T 281.17-2011
Basic data Standard ID | YS/T 281.17-2011 (YS/T281.17-2011) | Description (Translated English) | Methods for chemical analysis of cobalt. Part 17: Determination of aluminum, manganese, nickel, copper zinc, cadmium, tin, antimony, lead and bismuth content. Inductively coupled plasma mass spectrometry | Sector / Industry | Nonferrous Metallurgy Industry Standard (Recommended) | Classification of Chinese Standard | H13 | Classification of International Standard | 77.120.70 | Word Count Estimation | 7,713 | Date of Issue | 2011-12-20 | Date of Implementation | 2012-07-01 | Regulation (derived from) | ?MIIT Announcement 2011 No.43 | Issuing agency(ies) | Ministry of Industry and Information Technology | Summary | This standard specifies the cobalt aluminum, manganese, Nickel, copper, zinc, determination of bismuth content, cadmium, tin, antimony, lead. This section applies to cobalt aluminum, manganese, Nickel, copper, zinc, cadmium, tin, antimony, Determination of bismuth content, lead. Measurement range: 0. 0001% to 0. 005%. |
YS/T 281.17-2011: Methods for chemical analysis of cobalt. Part 17: Determination of aluminum, manganese, nickel, copper zinc, cadmium, tin, antimony, lead and bismuth content. Inductively coupled plasma mass spectrometry
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of cobalt.Part 17. Determination of aluminum, manganese, nickel, copper zinc, cadmium, tin, antimony, lead and bismuth content.Inductively coupled plasma mass spectrometry
ICS 77.120.70
H13
People's Republic of China Nonferrous Metals Industry Standard
Cobalt chemical analysis method
Part 17. aluminum, manganese, nickel, copper, zinc,
Determination of cadmium, tin, antimony, lead and bismuth
Inductively coupled plasma mass spectrometry
Part 17. Determination ofaluminum, manganese, nickel, copper
zinc, cadmium, tin, antimony, leadandbismuthcontent-
2011-12-20 release.2012-07-01 implementation
Issued by the Ministry of Industry and Information Technology of the People's Republic of China
Foreword
YS/T 281 "cobalt chemical analysis method" is divided into the following 20 parts.
Part 1. Determination of iron content - Sulfosalicylic acid spectrophotometric method
Part 2. Determination of aluminum content - Chromazu S spectrophotometric method
Part 3. Determination of silicon content - Molybdenum blue spectrophotometric method
Part 4. Determination of arsenic content - Molybdenum blue spectrophotometric method
- Part 5. Determination of phosphorus content - Molybdenum blue spectrophotometric method
Part 6. Determination of magnesium content - Flame atomic absorption spectrometric method
- Part 7. Determination of zinc content - Flame atomic absorption spectrometric method
Part 8. Determination of cadmium content - Flame atomic absorption spectrometric method
Part 9. Determination of lead content - Flame atomic absorption spectrometric method
Part 10. Determination of nickel content - Flame atomic absorption spectrometric method
- Part 11. Determination of copper and manganese - Flame atomic absorption spectrometric method
- Part 12. Determination of arsenic, antimony, bismuth, tin and lead - Electrothermal atomic absorption spectrometry
- Part 13. Determination of sulfur content - High frequency induction furnace combustion infrared absorption method
- Part 14. Determination of carbon content - High frequency induction furnace combustion infrared absorption method
- Part 15. Determination of arsenic, antimony and bismuth - Hydride generation - atomic fluorescence spectrometry
- Part 16. Determination of the amount of arsenic, cadmium, copper, zinc, lead, bismuth, tin, antimony, silicon, manganese, iron, nickel, aluminum and magnesium.
Spectrum method
- Part 17. Determination of aluminum, manganese, nickel, copper, zinc, cadmium, tin, antimony, lead and bismuth inductively coupled plasma mass spectrometry
- Part 18. Determination of sodium content - Flame atomic absorption spectrometric method
- Part 19. Determination of calcium, magnesium, manganese, iron, cadmium and zinc - Inductively coupled plasma emission spectrometric method
- Part 20. Determination of the amount of oxygen - Infrared absorption method
This part is part 17 of YS/T 281.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part of the National Nonferrous Metals Standardization Technical Committee (SAC/TC243) proposed and centralized.
This standard is responsible for drafting units. Jinchuan Group Co., Ltd., Beijing Mining and Metallurgy Research Institute.
This part is responsible for drafting units. Beijing Mining and Metallurgy Research Institute.
This part participates in the drafting unit. Beijing Nonferrous Metals Research Institute, Jinchuan Group Co., Ltd.
The main drafters of this part. Feng Xianjin, Li Huachang, Jiang Qiutao, Ruan Guiqing, Zhang Zhuo, Wang Kezhen, Lv Qingcheng.
Cobalt chemical analysis method
Part 17. aluminum, manganese, nickel, copper, zinc,
Determination of cadmium, tin, antimony, lead and bismuth
Inductively coupled plasma mass spectrometry
WARNING. Personnel using this standard should have practical experience in formal laboratory work. This standard does not indicate all possible security issues.
It is the responsibility of the user to take appropriate safety and health measures and to ensure compliance with the conditions set forth in the relevant national regulations.
1 Scope
This part of YS/T 281 specifies the determination method for the content of aluminum, manganese, nickel, copper, zinc, cadmium, tin, antimony, lead and bismuth in cobalt.
This part is applicable to the determination of aluminum, manganese, nickel, copper, zinc, cadmium, tin, antimony, lead and bismuth in cobalt. Measuring range. 0.0001% ~
0.005%.
2 method summary
The samples were dissolved in nitric acid and measured in a dilute nitric acid medium by ICP-MS-standard addition and on-line addition of scandium, rhodium and rhenium
Cobalt, zinc, cadmium, tin, antimony, lead, bismuth 10 kinds of elements.
3 reagent
The resistivity of the preparation solution and the analytical water is & gt; 18 MΩ · cm. The containers used in the experiments were thoroughly soaked with nitric acid (19) and thoroughly washed with water
Cleaning.
3.1 nitric acid (ρ = 1.42 g/mL), BV III grade.
3.2 Hydrochloric acid (ρ = 1.19 g/mL), BV III grade.
3.3 nitric acid (1 1).
3.4 Hydrochloric acid (1 1).
3.5 Hydrochloric acid (1 4).
3.6 nitric acid (19).
3.7 aluminum standard storage solution. Weigh 1.0000g metal aluminum (wAl ≥ 99.99%), placed in a 300mL beaker, add 20mL hydrochloric acid
(3.2), drop 1mL ~ 2mL nitric acid (3.1), dissolve at low temperature, into 1000mL volumetric flask, add 80mL hydrochloric acid (3.2) with water
Constant volume, mix. 1 mL of this solution contains 1 mg of aluminum.
3.8 Manganese standard storage solution. Weigh 1.0000 g of metal manganese (wMn ≥ 99.95%), placed in 150mL beaker, add 150mL of nitrate
Acid (3.6), heat dissolved, cooled, into the 1000mL volumetric flask, the water volume, mixing. 1 mL of this solution contains 1 mg of manganese.
3.9 copper standard storage solution. Weigh 1.0000g metal copper (wCu ≥ 99.99%), placed in a 300mL beaker, add 10mL nitric acid
(3.6), dissolved in low temperature, heated to remove nitrogen oxides, remove the cooling, into the 1000mL volumetric flask, add 100mL nitric acid (3.6),
Water volume, mix. 1 mL of this solution contains 1 mg of copper.
3.10 nickel standard storage solution. Weigh 1.0000g metal nickel (wNi ≥ 99.99%), placed in a 300mL beaker, add 10mL nitric acid
(3.6), dissolved in low temperature, heated to remove nitrogen oxides, remove the cooling, into the 1000mL volumetric flask, add 100mL nitric acid (3.6),
Water volume, mix. This solution 1mL containing 1mg nickel.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 281.17-2011_English be delivered?Answer: Upon your order, we will start to translate YS/T 281.17-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YS/T 281.17-2011_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 281.17-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|