HOME   Cart(2)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

YC/T 253-2019 English PDF

US$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YC/T 253-2019: (Cigarettes Determination of hydrogen cyanide in mainstream smoke Continuous flow method)
Status: Valid

YC/T 253: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YC/T 253-2019English169 Add to Cart 3 days [Need to translate] (Cigarettes Determination of hydrogen cyanide in mainstream smoke Continuous flow method) Valid YC/T 253-2019
YC/T 253-2008English319 Add to Cart 3 days [Need to translate] Cigarettes. Determination of hydrogen cyanide in cigarette mainstream smoke. Continuous flow method Obsolete YC/T 253-2008

PDF similar to YC/T 253-2019


Standard similar to YC/T 253-2019

YC/T 246   GB 5606.2   GB/T 5606.1   YC/T 244   YC/T 245   YC/T 243   

Basic data

Standard ID YC/T 253-2019 (YC/T253-2019)
Description (Translated English) (Cigarettes Determination of hydrogen cyanide in mainstream smoke Continuous flow method)
Sector / Industry Tobacco Industry Standard (Recommended)
Classification of Chinese Standard X87
Classification of International Standard 65.160
Word Count Estimation 7,760
Date of Issue 2019
Date of Implementation 2020-01-15
Issuing agency(ies) State Tobacco Monopoly Administration

YC/T 253-2019: (Cigarettes Determination of hydrogen cyanide in mainstream smoke Continuous flow method)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Cigarettes Determination of hydrogen cyanide in mainstream smoke Continuous flow method) ICS 65.160 X87 People's Republic of China Tobacco Industry Standard Replace YC/T 253-2008 Determination of hydrogen cyanide in mainstream cigarette smoke Continuous flow method 2019-12-26 released 2020-01-15 implementation Issued by the State Tobacco Monopoly Administration

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009 and GB/T.20001.4-2015. This standard replaces YC/T 253-2008 "Continuous flow method for the determination of hydrogen cyanide in mainstream cigarette smoke". With YC/T 253- Compared with.2008, the main technical changes except for editorial changes are as follows. ---Modified reagents and materials (see Chapter 4, Chapter 4 of the.2008 edition); ---Modified the equipment (see Chapter 5, Chapter 5 of the.2008 edition); ---Added the pretreatment of the filter (see 6.1 and 6.2); --- Increased the capture of hydrogen cyanide by the rotary smoking machine (see 6.4); ---Modified sample pre-processing and analysis (see 7.1, Chapter 7 of the.2008 edition); ---Revised the results and presentation (see Chapter 8); ---Modified the recovery rate and detection limit of the method (see Chapter 9, Chapter 9 of the.2008 edition); --- Increased the precision of the method (see 9.3). Please note that certain contents of this document may involve patents. The issuing agency of this document is not responsible for identifying these patents. This standard was proposed by the State Tobacco Monopoly Administration. This standard is under the jurisdiction of the National Tobacco Standardization Technical Committee Cigarette Sub-committee (SAC/TC144/SC1). Drafting organizations of this standard. Shanghai Tobacco Group Co., Ltd., China Tobacco Hunan Industry Co., Ltd., National Tobacco Quality Supervision and Inspection Inspection Center, China National Tobacco Corporation Beijing Branch, Zhejiang China Tobacco Industry Co., Ltd., Guizhou China Tobacco Industry Co., Ltd., Anhui China Tobacco Industry Co., Ltd., Gansu Tobacco Industry Co., Ltd., Yunnan Tobacco Quality Supervision and Testing Station. The main drafters of this standard. Liu Xingyu, Zhou Jun, Du Wen, Cao Jihong, Ma Li, Ma Yanjun, Bai Ruoshi, Yan Lihong, Zhang Wei, Fang Yi, Zhou Guojun, Liu Jian, Wang Ran, Peng Sa, Peng Lijuan, Liu Deshui, Lu Nan, Liu Nan, Jiang Xingyi, Shang Mengqi, Xia Jun, Ji Houwei, Zhang Chao, Zang Zhipeng, Li Xuemei. The previous versions of the standard replaced by this standard are as follows. ---YC/T 253-2008. Determination of hydrogen cyanide in mainstream cigarette smoke Continuous flow method

1 Scope

This standard specifies the continuous flow determination method of hydrogen cyanide release in mainstream cigarette smoke. This standard applies to the determination of hydrogen cyanide in mainstream cigarette smoke.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 5606.1 Cigarette Part 1.Sampling GB/T 6682 Analytical laboratory water specifications and test methods GB/T 19609 Smoking machine for routine analysis of cigarettes for determination of total particulate matter and tar

3 Principle

Filters pretreated with sodium hydroxide-ethanol/water solution are used to capture hydrogen cyanide in mainstream cigarette smoke. The captured filter, after Sodium hydroxide solution is leached to obtain a sample solution. Under slightly acidic conditions, the cyanide ion in the sample solution reacts with chloramine T to generate cyanogen chloride. Cyanogen chloride reacts with isonicotinic acid to form pentenedial compounds through hydrolysis, and then reacts with 1,3-dimethylbarbituric acid to form blue compounds. The absorbance was detected at 600nm.

4 Reagents and materials

The experimental water meets the requirements of Grade 1 water in GB/T 6682. 4.1 Sodium hydroxide, purity ≥99.0%. 4.2 Standard material for cyanide component analysis in water [GB W(E)080115]. 4.3 Chloramine T (CAS number. 127-65-1), purity ≥95.0%. 4.4 Potassium hydrogen phthalate (CAS number. 877-24-7), purity ≥99.0%. 4.5 Isonicotinic acid (CAS number. 55-22-1), purity ≥99.0%. 4.6 1,3-Dimethylbarbituric acid (CAS number. 769-42-6), purity ≥98.0%. 4.7 Concentrated hydrochloric acid, 36%~38% (mass fraction). 4.8 Ethanol, purity ≥99.0%. 4.9 Polyoxyethylene lauryl ether (CAS number. 9002-92-0), purity ≥90%. 4.10 Polyoxyethylene lauryl ether solution Add 25.0 g of polyoxyethylene lauryl ether (4.9) to 100 mL of water, heat and stir until completely dissolved. 4.11 1.0mol/L hydrochloric acid solution Add 84.0mL concentrated hydrochloric acid (4.7) slowly to 500mL water, transfer to a 1000mL volumetric flask, dilute to the mark with water, and mix well.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YC/T 253-2019_English be delivered?

Answer: Upon your order, we will start to translate YC/T 253-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YC/T 253-2019_English with my colleagues?

Answer: Yes. The purchased PDF of YC/T 253-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YC/T 253-2019?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YC/T 253-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.