US$189.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. WS/T 509-2016: Regulation for prevention and control of healthcare associated infection in intensive care unit Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| WS/T 509-2016 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
Regulation for prevention and control of healthcare associated infection in intensive care unit
| Valid |
WS/T 509-2016
|
PDF similar to WS/T 509-2016
Basic data | Standard ID | WS/T 509-2016 (WS/T509-2016) | | Description (Translated English) | Regulation for prevention and control of healthcare associated infection in intensive care unit | | Sector / Industry | Health Industry Standard (Recommended) | | Classification of Chinese Standard | C05 | | Classification of International Standard | 11.020 | | Word Count Estimation | 8,860 | | Date of Issue | 2016-12-27 | | Date of Implementation | 2017-06-01 | | Quoted Standard | GB 15982; WS/T 311; WS/T 312; WS/T 313; WS/T 367 | | Regulation (derived from) | State-Health-Communication (2016) No.23 | | Issuing agency(ies) | National Health and Family Planning Commission of the People's Republic of China | | Summary | This standard applies to all levels of general hospitals in accordance with the relevant provisions of the ICUo infectious disease hospital ICU and pediatric and neonatal ICU hospital infection prevention and control can be combined with professional characteristics, with reference to the implementation of this standard. |
WS/T 509-2016: Regulation for prevention and control of healthcare associated infection in intensive care unit ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Regulation for prevention and control of healthcare associated infection in intensive care unit
ICS 11.020
C05
People's Republic of China health industry standards
Intensive Care Unit nosocomial infection prevention and control norms
Regulation for prevention and control of health care associated infections
2016-12-27 release
2017-06-01 Implementation
People's Republic of China National Health and Family Planning Commission released
Foreword
This standard is formulated in accordance with Law of the People's Republic of China on Prevention and Treatment of Infectious Diseases and Measures for the Management of Nosocomial Infections.
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard was drafted. Xuanwu Hospital, Capital Medical University, Xiangya Hospital, Central South University, Peking University People's Hospital, Shandong Provincial Hospital,
Peking University First Hospital, Beijing Union Medical College Hospital.
Drafters of this standard. Wang Lihong, Wu Anhua, An Youzhong, Li Weiguang, Zhao Xia, Zhang Jingli, Li Liuyi, Du Bin.
Intensive Care Unit nosocomial infection prevention and control norms
1 Scope
This standard specifies the medical institutions intensive care unit (ICU) hospital infection prevention and control of the basic requirements,
Building Layout and Necessary Facilities and Management Requirements, Personnel Management, Monitoring of Nosocomial Infection, Prevention and Control of Device-Related Infections, Surgery Department
Bit infection prevention and control measures, hand hygiene requirements, environmental cleaning and disinfection methods and requirements, bed unit cleaning and disinfection requirements, toilet clean
Washing and disinfection requirements, air disinfection methods and requirements.
This standard applies to all levels of general hospitals set in accordance with the relevant provisions of the ICU.
Infectious disease hospital ICU and pediatric and neonatal ICU hospital infection prevention and control can be combined with professional characteristics, with reference to the implementation of this standard.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB 15982 hospital disinfection health standards
WS/T 311 Hospital isolation technical specifications
WS/T 312 nosocomial infection monitoring norms
WS/T 313 medical staff hand hygiene specification
WS/T 367 medical institutions disinfection specifications
Medical Waste Management Regulations.2003 State Council
Measures for the Administration of Medical Wastes in Medical and Health Institutions The Ministry of Health.2003 Edition
Medical waste classification catalog former Ministry of Health, State Environmental Protection Administration.2003 edition
Disinfection management approach the former Ministry of Health.2002 edition
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Intensive care unit intensive careunit; ICU
Hospital intensive care and treatment of critically ill patients in specialized wards, for various reasons lead to one or more organs and system dysfunction
And patients with life-threatening or potentially risky conditions to provide systematic, high-quality medical care and treatment in a timely manner.
3.2
Air clean technology aircleaningtechnology
Multi-stage air filtration system to remove suspended particles and microorganisms in the air, creating a clean environment means.
3.3
Central catheter centralline
Endovascular catheters for infusion, blood transfusion, blood collection, hemodynamic monitoring at or near the heart or one of the following major vessels.
These large vessels include. aorta, pulmonary artery, superior vena cava, inferior vena cava, brachiocephalic vein, internal jugular vein, subclavian vein, external iliac vein,
vein.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of WS/T 509-2016_English be delivered?Answer: Upon your order, we will start to translate WS/T 509-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of WS/T 509-2016_English with my colleagues?Answer: Yes. The purchased PDF of WS/T 509-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|