US$169.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 4118-2015: Determination of short-chain chlorinated paraffins in paints and coatings Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
SN/T 4118-2015 | English | 169 |
Add to Cart
|
3 days [Need to translate]
|
Determination of short-chain chlorinated paraffins in paints and coatings
| Valid |
SN/T 4118-2015
|
PDF similar to SN/T 4118-2015
Basic data Standard ID | SN/T 4118-2015 (SN/T4118-2015) | Description (Translated English) | Determination of short-chain chlorinated paraffins in paints and coatings | Sector / Industry | Commodity Inspection Standard (Recommended) | Classification of Chinese Standard | G51 | Classification of International Standard | 87.040 | Word Count Estimation | 7,799 | Date of Issue | 2015-02-09 | Date of Implementation | 2015-09-01 | Regulation (derived from) | State-Quality-Inspection-Accreditation [2015] 59 | Issuing agency(ies) | General Administration of Customs | Summary | This standard specifies the paints and coatings SCCPs (C10 ~ C13) by Gas Chromatography. This standard applies to paints and coatings SCCPs (C10 ~ C13) content determination. |
SN/T 4118-2015: Determination of short-chain chlorinated paraffins in paints and coatings---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Determination of paints and coatings SCCP Content)
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Determination of paints and coatings SCCPs Content
Issued on. 2015-02-09
2015-09-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. Shanxi People's Republic of China Exit Inspection and Quarantine.
The main drafters of this standard. Xue Ping, Du Lijun, Yao Yating, Dijin Yi, Guo Xiaoxi, Zhao long, Zhang Xinxin, Wang Dongbin.
Determination of paints and coatings SCCPs Content
1 Scope
This standard specifies the paints and coatings SCCPs (C10 ~ C13) by Gas Chromatography.
This standard applies to paints and coatings SCCPs (C10 ~ C13) content determination.
2 Method summary
After the samples were extracted with hexane ultrasonic extraction, centrifugation extracts were sulfonated sulfate, centrifuged supernatant Florey silica solid phase extraction (SPE)
Concentrated, constant volume, measured by gas chromatography, external standard.
3 Reagents and materials
Unless otherwise specified, all reagents were of analytical grade.
3.1 hexane. chromatographically pure.
3.2 ethyl acetate. chromatography.
3.3 of concentrated sulfuric acid (ρ = 1.98g/mL).
3.4 elution solvent. n-hexane ethyl acetate (10 1, VV).
3.5 Florisil SPE. 1g/3mL.
3.6 Nitrogen. purity ≥99.999%.
3.7 Short-chain chlorinated paraffins (C10 ~ C13) standard solution. 100μg/mL, the chlorine content of 55.5%.
3.8 Short-chain chlorinated paraffins (C10 ~ C13) standard solution. 100μg/mL, chlorine content of 51.5%.
3.9 Short-chain chlorinated paraffins (C10 ~ C13) standard solution. 100μg/mL, chlorine content of 63%.
3.10 SCCP standard solution. 10μg/mL, were taken SCCPs (C10 ~ C13) standard solution (3.7,3.8,
3.9) 1.0mL, diluted with n-hexane and dilute to 10mL.
4 instruments and equipment
4.1 Gas chromatograph. with electron capture detector (ECD) and autosampler.
4.2 centrifuge. speed can reach 4000r/min.
4.3 sonicator.
4.4 nitrogen blowing instrument.
Than 4.5 colorimetric tube. 25mL.
4.6 Analysis of balance. a sense of the amount of 0.1mg.
Step 5 Analysis
5.1 ultrasonic extraction
Weigh the sample 0.5g, accurate to 0.0001g, into 25mL colorimetric tube (4.5) was added 10.0mL n-hexane (3.1), ultrasound
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 4118-2015_English be delivered?Answer: Upon your order, we will start to translate SN/T 4118-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of SN/T 4118-2015_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 4118-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|