SN/T 3713-2013: Screening of chromium pigment in paints-Inductively coupled plasma atomic emission spectrometry
Status: Valid
| Std ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status |
| SN/T 3713-2013 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Screening of chromium pigment in paints-Inductively coupled plasma atomic emission spectrometry
| Valid |
Basic data
| Standard ID | SN/T 3713-2013 (SN/T3713-2013) |
| Description (Translated English) | Screening of chromium pigment in paints-Inductively coupled plasma atomic emission spectrometry |
| Sector / Industry | Commodity Inspection Standard (Recommended) |
| Classification of Chinese Standard | G50 |
| Classification of International Standard | 87.010 |
| Word Count Estimation | 8,832 |
| Quoted Standard | GB/T 602; GB/T 6682; GB/T 8170; GB/T 23942 |
| Regulation (derived from) | National quality recognition (2013) 569 |
| Issuing agency(ies) | General Administration of Customs |
| Summary | This standard specifies the inductively coupled plasma-atomic emission spectrometry method for screening the chromium coating pigments. This standard applies to screening chrome yellow paint, lead chromate, chromium molybdenum and red pigments. This stand |
SN/T 3713-2013: Screening of chromium pigment in paints-Inductively coupled plasma atomic emission spectrometry
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Screening of chromium pigment in paints-Inductively coupled plasma atomic emission spectrometry
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Paint pigments containing chromium screening method
Inductively coupled plasma atomic emission spectrometry
Issued on. 2013-11-06
2014-06-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China Zhejiang Exit Inspection and Quarantine drafted.
The main drafters of this standard. Xu Xiaochun, Yong-Hua Guo, Zhou Ying, Zhao Hong Shan, Ruan Yi, Wang Chen.
Paint pigments containing chromium screening method
Inductively coupled plasma atomic emission spectrometry
Warning. Use of this standard shall have a person experiences regular laboratory work. This standard does not point out all possible security issues.
Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.
1 Scope
This standard specifies the inductively coupled plasma atomic emission spectrometry method for screening the chromium coating pigments.
This standard applies to screening paint chrome yellow, lead chromate, molybdenum, chromium and red pigments.
This standard does not apply to chrome green paint.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
Preparation of standard solution of GB/T 602 Determination of impurities in chemical reagents
Laboratory use specifications and test methods GB/T 6682 Analysis
GB/T 8170 repair value expressed about the rules and limit values and judgment
GB/T 23942 Chemicals inductively coupled plasma atomic emission spectrometry General
3 Method Summary
After the paint were coated and dried by microwave digestion method to remove all organic material, after constant volume by inductively coupled plasma atomic emission
Spectrometry, chromium content is calculated according to the curve.
4 Reagents and materials
Unless otherwise indicated, the reagents used were of analytical grade standard, distilled or deionized water should be consistent with GB/T 6682 two water requirements.
4.1 nitric acid (ρ = 1.42g/mL).
4.2 Hydrogen peroxide (ρ = 1.10g/mL).
4.3 Chromium standard solution. the concentration of chromium 1000μg/mL standard solution prepared according to GB/T 602 method, or direct use of
Chromium standard solution reference material certificate within the validity period.
5 Instruments
5.1 Inductively coupled plasma atomic emission spectrometer, the reciprocal linear dispersion rate stability (short-range, long-range), and the background equivalent concentration detection limit,
The calibration curve shall comply with GB/T 23942 of. Instrument conditions, see informative Annex A.
5.2 microwave digestion. Microwave digestion temperature control routine samples see informative Annex B.
5.3 Balance. a sense of the amount of 0.1mg.

Tips & Frequently Asked Questions:
Question 1: How long will the true-PDF of SN/T 3713-2013_English be delivered?
Answer: Upon your order, we will start to translate SN/T 3713-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.
Question 2: Can I share the purchased PDF of SN/T 3713-2013_English with my colleagues?
Answer: Yes. The purchased PDF of SN/T 3713-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.
Question 3: Does the price include tax/VAT?
Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):
List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?
Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.