HOME Cart(0) Quotation About-Us Policies PDFs Standard-List
www.ChineseStandard.net Database: 221870 (13 Apr 2026)
Path: Home > SN/T > Page38 > SN/T 3708-2013 || Home > Standard_List > SN/T > Page38 > SN/T 3708-2013

SN/T 3708-2013 PDF English

Price & Delivery

US$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 3708-2013: Determination of silicon and phosphorus content in ferrochromium. Microwave digestion-inductively coupled plasma atomic emission spectrometric method
Status: Valid
Std IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)Status
SN/T 3708-2013English209 Add to Cart 3 days [Need to translate] Determination of silicon and phosphorus content in ferrochromium. Microwave digestion-inductively coupled plasma atomic emission spectrometric method Valid

Standard similar to SN/T 3708-2013

GB/T 3654.3 | GB/T 4336 | GB/T 4701.1 | SN/T 5570 | SN/T 4757 | SN/T 3709 |

Basic data

Standard ID SN/T 3708-2013 (SN/T3708-2013)
Description (Translated English) Determination of silicon and phosphorus content in ferrochromium. Microwave digestion-inductively coupled plasma atomic emission spectrometric method
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard H11
Classification of International Standard 77.100
Word Count Estimation 8,829
Quoted Standard GB/T 4010; GB/T 602; GB/T 6682; JJG 768
Regulation (derived from) National quality recognition (2013) 569
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the use of microwave digestion - inductively coupled plasma atomic emission spectrometry (ICP-AES) method iron silicon (Si) and phosphorus (P) content determined by the method. This standard applies to the determination of iron in

SN/T 3708-2013: Determination of silicon and phosphorus content in ferrochromium. Microwave digestion-inductively coupled plasma atomic emission spectrometric method



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of silicon and phosphorus content in ferrochromium. Microwave digestion-inductively coupled plasma atomic emission spectrometric method People's Republic of China Entry-Exit Inspection and Quarantine Standards Determination microwave ferrochrome silicon and phosphorus content of digestion - Inductively coupled plasma atomic emission spectrometry Issued on. 2013-11-06 2014-06-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. People's Republic of China Hunan Exit Inspection and Quarantine, People's Republic of China Guangdong Entry-Exit Inspection and Quarantine Bureau. The main drafters of this standard. Yang Wanbiao, hairy, Lu small garden, Chenxin Huan, Chen training, Liu Zhenghua, Xiaojia Yong, Luo Lirong. Determination microwave ferrochrome silicon and phosphorus content of digestion - Inductively coupled plasma atomic emission spectrometry

1 Scope

This standard specifies the microwave digestion - inductively coupled plasma atomic emission spectrometry (ICP-AES) Determination of ferrochrome silicon (Si) and phosphorus (P) method content. This standard applies to the determination of ferrochrome silicon and phosphorus content. Determination of the mass fraction range. Si. 0.10% - 7.50%; P. 0.0050% ~ 0.50%.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. Preparation of standard solution of GB/T 602 Determination of impurities in chemical reagents GB/T 4010 alloy chemical analysis and preparation of samples Laboratory use specifications and test methods GB/T 6682 Analysis JJG768 Emission Spectrometer

3 Method summary

Sample in microwave digestion with hydrochloric acid, nitric acid, hydrofluoric acid dissolved, boric acid complexation excess hydrofluoric acid, the digestion was treated with Inductively coupled plasma atomic emission spectrometer to determine the content of each element according to the working curve.

4 Reagents and materials

Unless otherwise indicated, the use of reagents of recognized analytical grade and above in the analysis only and in accordance with GB/T 6682 specified secondary water. 4.1 HCl. ρ = 1.19g/mL. Nitrate 4.2. ρ = 1.42g/mL. 4.3 Hydrofluoric acid. ρ = 1.15g/mL. 4.4 boric acid. pure spectrum. 4.5 chromium. chromium content ≥99.99%. 4.6 high purity iron. iron content ≥99.988%. 4.7 hydrochloric acid. 11. 4.8 mixed acid. hydrochloric acid. nitric acid. water = 3.3.94. 4.9 boric acid solution (5%). Weigh 5g boric acid (4.4) were dissolved in 100mL water. 4.10 chromium matrix solution (20mg/mL). Weigh 2.00g ± 0.01g chromium (4.5), add 20mL of hydrochloric acid (4.1), low heat to dissolve, Cooled and transferred to 100mL volumetric flask, dilute to the mark with water, and mix stored in a plastic bottle. 4.11 iron matrix solution (10mg/mL). Weigh 1.00g ± 0.01g high iron (4.6), add water, moist, added in small sub-total 15mL Hydrochloric acid (4.1), low-temperature heating, dissolved completely transferred to 100mL volumetric flask, dilute with water to volume, and mix.
SN/T 3708-2013 English cover page

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 3708-2013_English be delivered?

Answer: Upon your order, we will start to translate SN/T 3708-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 3708-2013_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 3708-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
Terms of Service | Contact Information | Privacy Policy | Refund Policy | Shipping Policy