US$159.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 3319.2-2012: Ferrophorus for import and export. Part 2: Determination of manganese content. Periodate spectrophotometric method Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| SN/T 3319.2-2012 | English | 159 |
Add to Cart
|
3 days [Need to translate]
|
Ferrophorus for import and export. Part 2: Determination of manganese content. Periodate spectrophotometric method
| Valid |
SN/T 3319.2-2012
|
PDF similar to SN/T 3319.2-2012
Basic data | Standard ID | SN/T 3319.2-2012 (SN/T3319.2-2012) | | Description (Translated English) | Ferrophorus for import and export. Part 2: Determination of manganese content. Periodate spectrophotometric method | | Sector / Industry | Commodity Inspection Standard (Recommended) | | Classification of Chinese Standard | H42 | | Word Count Estimation | 6,622 | | Quoted Standard | GB/T 6379.2; GB/T 6682 | | Regulation (derived from) | National Quality Inspection (2012) 777; industry standard filing Notice 2013 No. 4 (No. 160 overall) | | Issuing agency(ies) | General Administration of Customs | | Summary | This standard specifies the periodate photometric determination of phosphorus in iron manganese content approach. This standard applies to phosphorus iron manganese content, measuring range from 0. 01% to 2. 50%. |
SN/T 3319.2-2012: Ferrophorus for import and export. Part 2: Determination of manganese content. Periodate spectrophotometric method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Ferrophorus for import and export.Part 2. Determination of manganese content.Periodate spectrophotometric method
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Importers phosphorus iron - Part 2.
Determination of manganese content periodate spectrophotometry
Ferrophorusforimportandexport-Part 2. Determinationof
Issued on. 2012-12-12
2013-07-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
SN/T 3319 "Importers phosphorus iron" is divided into two parts.
--- Part 1. Determination of the inductor phosphorus, manganese, silicon, titanium, vanadium, chromium coupled plasma atomic emission spectrometry;
--- Part 2. Determination of manganese content periodate spectrophotometry.
This section SN/T 3319 Part 2.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section proposed and managed by the National Certification and Accreditation Administration Committee.
This section is drafted. Tianjin People's Republic of China Exit Inspection and Quarantine.
The main drafters of this section. Wangzhen Kun, Chen Yan, Li Yi, Yao Zhuangang, Gu Songhai, Wang Haoyun, Zhang Hui, Su Mingyue.
Importers phosphorus iron - Part 2.
Determination of manganese content periodate spectrophotometry
1 Scope
SN/T 3319 This section specifies the method of periodate spectrophotometric determination of phosphorus in the iron and manganese content.
This section applies to the determination of phosphorus in the iron and manganese content, the measurement range of 0.01% to 2.50%.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2. Determine the standard measurement method to repeat
Of the basic methods of reproduction
Laboratory use specifications and test methods GB/T 6682 Analysis
3 Method summary
Sample was dissolved in hydrofluoric acid, nitric acid and hydrochloric acid was added parathion mixed acid is heated until white smoke when sulfur trioxide, nitric acid solution of the sample solution
Solution, the insoluble residue was filtered with filter paper, high temperature ashing by sulfuric acid, hydrofluoric acid treatment, high temperature melting potassium pyrophosphate, sulfuric acid leaching, high added
Potassium iodate peroxide solution, after constant volume absorbance was measured at 530nm wavelength, determines the content from the working curve.
4 Reagents and materials
Unless otherwise noted, all reagents were analytical grade water to comply with two water GB/T 6682 regulations.
4.1 Hydrofluoric acid (ρ = 1.15g/mL).
4.2 hydrochloric acid (ρ = 1.19g/mL).
4.3 nitric acid (ρ = 1.42g/mL).
4.4 phosphoric acid (ρ = 1.70g/mL).
4.5 sulfate (ρ = 1.84g/mL).
4.6 potassium pyrosulfate.
4.7 phosphate (11).
4.8 sulfate (11).
4.9 sulfate (14).
4.10 high potassium iodate solution (50g/L). Weigh 5g potassium periodate placed in 250mL beaker, add 60mL water, add 15mL of nitric acid
Warmed to dissolve, cooled to room temperature, transferred to 100mL volumetric flask, dilute to the mark with water and mix.
4.11 sodium nitrite solution (10g/L). Weigh 1g of sodium nitrite into 250mL beaker, add 60mL water, completely dissolved shift
Into 100mL volumetric flask, dilute to the mark and mix.
4.12 Manganese standard solution.
4.12.1 manganese standard stock solution (1000mg/L). Manganese standard solution using a national certified reference materials.
|