Basic data | Standard ID | SN/T 3098-2012 (SN/T3098-2012) | | Description (Translated English) | Evaluation method of environmental performance for zinc-coated sheet | | Sector / Industry | Commodity Inspection Standard (Recommended) | | Classification of Chinese Standard | H46 | | Classification of International Standard | 77.140.50 | | Word Count Estimation | 5,548 | | Quoted Standard | GB/T 1839; GB/Z 21274; GB/Z 21275; EU ROHS directive on electrical and electronic equipment on the Restriction of Hazardous Substances Directive; EU ROHS directive for the development of hazardous substances in electrical and electronic equipment maximum | | Regulation (derived from) | National Quality Inspection (2012) 237; industry standard filing Notice 2012 No. 9 (Total No. 153); | | Issuing agency(ies) | General Administration of Customs | | Summary | This standard specifies the environmental performance of galvanized sheet evaluation method. This standard applies to electro-galvanized sheet and hot dip galvanized environmental performance evaluation. |
SN/T 3098-2012: Evaluation method of environmental performance for zinc-coated sheet---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Evaluation method of environmental performance for zinc-coated sheet
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Galvanized sheet Environmental Performance Evaluation Method
Issued on. 2012-05-07
2012-11-16 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China Guangdong CIQ, People's Republic of China Shandong Entry-Exit Inspection and
Quarantine Bureau.
The main drafters of this standard. Momin Zhen, Tan Ying, Chen Guifeng, Shisong Jie, Zhou Qi, Li Xiaomin, Chen, Cao standard.
Galvanized sheet Environmental Performance Evaluation Method
1 Scope
This standard specifies the environmental performance evaluation method of galvanized sheet.
This standard applies to environmental performance evaluation galvanized sheet and galvanized sheet.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 1839 quality steel products galvanizing layer test method
GB/Z21274 restricted substances in electrical and electronic products, lead, mercury, cadmium detection method
GB/Z21275 restricted substances in electrical and electronic products hexavalent chromium detection method
EU RoHS Directive on electrical and electronic equipment in the Restriction of Hazardous Substances Directive (2002/95/EC)
EU RoHS directive for the development of the maximum concentration values of hazardous substances in electrical and electronic equipment, the European Parliament and Council Directive 2002/95 /
EC Directive (2005/618/EC)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Galvanized zinc-coatedsheet
A layer of zinc plated steel.
3.2
Environmental performance environnmentalperformance
The degree of environmental safety performance in line with the EU RoHS directive, namely the hazardous substances lead, mercury, cadmium, hexavalent chromium and the EU RoHS Directive
Degree of compliance.
4 Environmental Performance Requirements
Maximum galvanized sheet surface layer of galvanized allowed lead, mercury, hexavalent chromium content is 0.1% (mass fraction), the maximum allowed value of cadmium content
0.01% (mass fraction).
5 Test methods
Release 5.1 galvanized sheet surface galvanized layer may reference GB/T 1839 carried out.
5.2 galvanized sheet galvanized surface layer of harmful substances Determination of lead, mercury, cadmium, hexavalent chromium content may refer to GB/Z21274, GB/Z21275
get on.
|