 SN/T 3019.2-2013: Determination of halogen content in electrical and electronic equipment. Part 2: Combustion in oxygen capsule and ion chromatography
 Status: Valid
 
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |  
			| SN/T 3019.2-2013 | English | 319 | Add to Cart | 3 days [Need to translate] | Determination of halogen content in electrical and electronic equipment. Part 2: Combustion in oxygen capsule and ion chromatography | Valid | SN/T 3019.2-2013 |  
	 
       PDF similar to SN/T 3019.2-2013 
 Basic data             | Standard ID | SN/T 3019.2-2013 (SN/T3019.2-2013) |           | Description (Translated English) | Determination of halogen content in electrical and electronic equipment. Part 2: Combustion in oxygen capsule and ion chromatography |           | Sector / Industry | Commodity Inspection Standard (Recommended) |           | Classification of Chinese Standard | K04 |           | Classification of International Standard | 31.020 |           | Word Count Estimation | 12,170 |           | Quoted Standard | GB/T 6682; GB/Z 20288 |           | Regulation (derived from) | National quality recognition (2013) 569 |           | Issuing agency(ies) | General Administration of Customs |           | Summary | This standard specifies the oxygen chamber combustion ion chromatography method of combustible materials in electrical and electronic products halogen. This standard applies to the determination of electrical and electronic products halogen. | SN/T 3019.2-2013: Determination of halogen content in electrical and electronic equipment. Part 2: Combustion in oxygen capsule and ion chromatography---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
 Determination of halogen content in electrical and electronic equipment.Part 2. Combustion in oxygen capsule and ion chromatography
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Determination of electrical and electronic products halogen
Part 2. oxygen chamber combustion ion chromatography
Part 2. Combustioninoxygencapsuleandionchromatography
Issued on. 2013-11-06
2014-06-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
 ForewordSN/T 3019 "Electrical and Electronic Products Halogen determination" is divided into two parts.
--- Part 1. Oxygen Bomb Combustion - Ion Chromatography;
--- Part 2. oxygen chamber combustion ion chromatography.
This section SN/T 3019 Part 2.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section proposed and managed by the National Certification and Accreditation Administration Committee.
This section was drafted by. People's Republic of China Jiangsu Entry-Exit Inspection and Quarantine Bureau, People's Republic of China Shanghai Entry-Exit Inspection and
Quarantine Bureau.
The main drafters of this part. He re-hui A Trial Wu Jing, Wen Wei Bi, Pansheng Lin, Zhang Yue, Wang Jinling, Xu Xiaoping, Zhang Sainan, Marcus Chin.
Determination of electrical and electronic products halogen
Part 2. oxygen chamber combustion ion chromatography
Warning. Use of this section shall be a person experiences regular laboratory work. This section does not indicate that all possible security issues.
Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions of the relevant provisions of the State.1 ScopeSN/T 3019 provisions of this part of the combustible materials in electrical and electronic products halogen oxygen chamber combustion ion chromatography method.
This section applies to the determination of halogen in electrical and electronic products.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
Laboratory use specifications and test methods GB/T 6682 Analysis
GB/Z20288 hazardous substances in electrical and electronic products in the test sample resolution General requirements3 Terms and DefinitionsThe following terms and definitions apply to this document.
3.1
Halogen halogen
Fluoro (F), chlorine (Cl), bromine (Br) and iodine (I) four elements.4 Method summaryThe analytical sample was crushed to a predetermined particle size, high temperature oxygen into the compartment cracking, oxidation, its product with the carrier gas into the absorbent liquid by ion chromatography
(IC) separation and determination, external standard.5 Reagents and materialsUnless otherwise specified, use only the gifted class pure reagents.
5.1 water, in line with GB/T 6682 Class 1 water.
5.2 Fluoride standard stock solution. Weigh at 100 ℃ ~ 105 ℃ drying to constant weight of sodium fluoride (NaF) 2.210g, dissolved in water, dilute to
1000mL, stored in polyethylene bottles, placed in the refrigerator for a period of two months. This solution was fluorinated ion 1000mg/L.
5.3 Chloride standard stock solution. Weigh at 500 ℃ ~ 600 ℃ ignition to constant weight of sodium chloride (NaCl) 1.648g, dissolved in water, dilute to
1000mL, placed in the refrigerator for a period of two months. The solution containing chlorine ions 1000mg/L.
5.4 bromine ion standard stock solution. Weigh at 100 ℃ ~ 105 ℃ drying to constant weight of potassium bromide (KBr) 1.489g, dissolved in water, dilute to
1000mL, placed in the refrigerator for a period of two months. The solution containing bromide ions 1000mg/L.
 
 Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 3019.2-2013_English be delivered?Answer: Upon your order, we will start to translate SN/T 3019.2-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of SN/T 3019.2-2013_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 3019.2-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries Question 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected] . In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.    |