HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (1 Nov 2025)

SN/T 2696-2010 English PDF

US$259.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 2696-2010: Determination of major and minor elements in coal ash and coke ash. X-ray fluorescenxe spectrometric method
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 2696-2010English259 Add to Cart 3 days [Need to translate] Determination of major and minor elements in coal ash and coke ash. X-ray fluorescenxe spectrometric method Valid SN/T 2696-2010

PDF similar to SN/T 2696-2010


Standard similar to SN/T 2696-2010

GB/T 2565   SN/T 2697   GB/T 2566   SN/T 2087.2   SN/T 5576   

Basic data

Standard ID SN/T 2696-2010 (SN/T2696-2010)
Description (Translated English) Determination of major and minor elements in coal ash and coke ash. X-ray fluorescenxe spectrometric method
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard D21
Classification of International Standard 73.040
Word Count Estimation 10,141
Date of Issue 2010-11-01
Date of Implementation 2011-05-01
Quoted Standard GB/T 1574; GB/T 6682; GB/T 16597
Adopted Standard ASTM D4326-2004, MOD
Regulation (derived from) National Quality Inspection (2010) 582
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the coal ash and coke ash into the major and minor elements by X-ray fluorescence spectrometry method. This standard applies to coal ash and coke ash ash and coal gangue silicon, aluminum, iron, calcium, magnesium, sodium, potassium, phosphorus and titanium content, measurement range of each element are shown in Table l.

SN/T 2696-2010: Determination of major and minor elements in coal ash and coke ash. X-ray fluorescenxe spectrometric method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of major and minor elements in coal ash and coke ash.X-ray fluorescenxe spectrometric method People's Republic of China Entry-Exit Inspection and Quarantine Standards Determination of coal ash and coke ash content in the primary and secondary elements X-ray fluorescence spectrometry Issued on. 2010-11-01 2011-05-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This revised standard adopts ASTMD4326.2004 "X-ray fluorescence method for the determination of coal ash and coke ash composition in major and minor elements Standard Test Method "(in English). This standard ASTMD4326.2004 compared, there is a technical difference. --- Remove ASTMD4326.2004 Table 1 strontium, lists only 12 elements measured; --- Remove ASTMD4326.2004 of 5.3 requirements for the use of graphite crucible; --- Remove ASTMD4326.2004 of 5.5 ASTME11 mesh should meet the specification requirements; --- Remove ASTMD4326. 5.8 in 2004 related to the energy dispersive X-ray fluorescence spectrometer requirements, delete and 5.8.2 With energy dispersive X-ray fluorescence spectrometer probes pertaining to the content; --- Remove ASTMD4326.2004 8.3 tablet method using the sample preparation step, delete and related compression method of sample preparation Instruments (5.6) and reagent (6.5); --- Remove ASTMD4326.2004 10.1-house laboratories can single measurement requirements; --- Remove ASTMD4326. precision requirements in 2004; --- Remove ASTMD4326.2004 "on coal and coke ash 7 Preparation", with GB/T 1574-1995 "ash composition analysis side Law "" 5 ash sample preparation "alternative; --- Modify ASTMD4326.2004 Description of the molten sample, increasing the melting detailed sampling procedures and all reagents. For ease of use, this standard also made the following editorial changes. --- Increasing the scope of this standard description; --- Modify the "Test methods" be replaced by "this standard"; --- Modify ASTMD4326.2004 in "5 Instrument" and "6 reagent" are organized adjusted to "4 Reagents and materials" and "5 Instruments"; --- Modify ASTMD4326.2004 in 6.4 "flux" added to the flux used in the description; --- Remove ASTMD4326.2004 The meaning and purpose; --- Delete ASTM standards specified number of instructions; --- Remove ASTMD4326. SI units described in 2004; --- Remove ASTMD4326.2004 is not intended to illustrate the description of all security matters; --- Remove ASTMD4326.2004 Keywords legend; --- Remove ASTMD4326.2004 safety warnings in the instructions. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. Tianjin People's Republic of China Exit Inspection and Quarantine, Ningbo Entry-Exit Inspection and People's Republic of China Quarantine Bureau. The main drafters of this standard. Gu Songhai, Song Yi, Guo Fen, Wei Hongbing, Su-Mei Wang, Pan Hongwei, forest edge, Zhang Jianbo. Determination of coal ash and coke ash content in the primary and secondary elements X-ray fluorescence spectrometry

1 Scope

This standard specifies the coal ash and coke ash into the main method of measuring the minor elements of X-ray fluorescence spectrometry. This standard applies to fly ash, coal gangue ash and coke ash determination of silicon, aluminum, iron, calcium, magnesium, sodium, potassium, phosphorus and titanium content of each element determination Range in Table 1. Table 1 coal ash and coke ash major and minor element oxides measurement range% Oxide Ash, dry Measurement range (mass fraction) SiO2 33.2 ~ 57.5 Al2O3 11.6 ~ 33.1 Fe2O3 3.1 ~ 41.8 CaO 1.5 ~ 25.2 MgO 0.4 ~ 4.5 Na2O 0.2 ~ 7.41 K2O 0.3 ~ 3.1 P2O5 0.1 ~ 3.4 TiO2 0.5 ~ 1.5 Note. MnO2, SO3 and BaO value as correcting the above nine elements. Test range MnO2. 0.008% ~ 0.26%; SO3. 0.05% ~ 2.84%; BaO. 0.41% ~ 14.72%.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 1574 ash component analysis Laboratory use specifications and test methods GB/T 6682 Analysis GB/T 16597 Metallurgical product analysis method X-ray fluorescence spectrometer General

3 Method summary

According to GB/T 1574 coal or coke sample ashes and burned to constant weight, with lithium tetraborate and lithium metaborate (12.22) mixed melt The molten sample ashing agent after the preparation of the test pieces, measuring X-ray fluorescence intensity measured elements, according to X-ray fluorescence of the analyte The quantitative relationship between intensity and analyte content, the choice of regression equations and mathematical correction mode, calculate the analyte content.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 2696-2010_English be delivered?

Answer: Upon your order, we will start to translate SN/T 2696-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 2696-2010_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 2696-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information