Basic data | Standard ID | SN/T 2207-2008 (SN/T2207-2008) | | Description (Translated English) | Determination of arsenic, calcium, lead content in food additive DL-tartaric acid for import and export. ICP-AES method | | Sector / Industry | Commodity Inspection Standard (Recommended) | | Classification of Chinese Standard | X04 | | Classification of International Standard | 67.220.20 | | Word Count Estimation | 8,826 | | Date of Issue | 2008-11-18 | | Date of Implementation | 2009-06-01 | | Quoted Standard | GB/T 602; GB/T 6682; GB 15358 | | Regulation (derived from) | National Quality Inspection [2008] No. 577 | | Issuing agency(ies) | General Administration of Customs | | Summary | This standard specifies the DL-tartaric acid food additive arsenic, cadmium, lead content by inductively coupled plasma atomic emission spectrometry method. This standard applies to food additives DL-tartaric acid in arsenic, cadmium, lead content. |
SN/T 2207-2008: Determination of arsenic, calcium, lead content in food additive DL-tartaric acid for import and export. ICP-AES method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of arsenic, calcium, lead content in food additive DL-tartaric acid for import and export.ICP-AES method
Exit inspection and quarantine industry standard book People's Republic of China
Import and export of food additives DL- tartrate
Determination of arsenic, cadmium, lead content
Inductively coupled plasma atomic emission spectrometry
Posted 2008-11-18
2009-06-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
The Standard Appendix A, Appendix B is an informative annex.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China Zhejiang Exit Inspection and Quarantine.
The main drafters of this standard. Dai Qi, Zhu Yu, Jiang Yongxiang, Zhang Xiao radon, Wu Yanyan, Zhu Qingqing, Yuan Jing.
This standard is the first release of the entry-exit inspection and quarantine industry standards.
Import and export of food additives DL- tartrate
Determination of arsenic, cadmium, lead content
Inductively coupled plasma atomic emission spectrometry
1 Scope
This standard specifies the food additive DL- tartaric acid of arsenic, cadmium, lead content by inductively coupled plasma atomic emission spectrometry
method.
This standard applies to the determination of arsenic in food additives DL- tartaric acid, calcium, lead content in.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 602 Determination of impurities in chemical reagents prepared standard solution (GB/T 602-2002, ISO 6353-1. 1982, NEQ) with
GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD)
3 Method summary
After the sample digestion, measured spectral intensity in the corresponding element ICP-AES wavelength, using the standard curve quantification.
4 Reagents and materials
Unless otherwise specified, the reagents were pure class distinctions, test water should meet the two water GB/T 6682 stipulated.
4.1 nitrate.
4.2 nitric acid solution (1 + 9). the amount of 10mL of nitric acid (4.1) diluted with water to 100mL.
4.3 single element standard stock solution. each element standard solution according to GB/T 602 method of preparation, or directly using a standard substance, its concentration
Are 1000μg/mL.
4.4 mixed standard solution. Pipette 1.0mL respectively lead, arsenic, calcium single-element standard stock solution (4.3) into 1000mL volumetric flask
Diluted nitric acid solution (4.2) and dilute to the mark, mix shift to clean polyethylene bottle containing the solution were
1μg/mL of lead, arsenic, calcium, stored in a refrigerator 0 ℃ ~ 4 ℃ in the period of one month.
4.5 Argon. not less than 99.99% purity.
5. Apparatus
5.1 Inductively coupled plasma atomic emission spectrometer.
5.2 Analysis of balance. a sense of the amount of 0.001g.
5.3 microwave digestion system.
6 Sample Preparation and Storage
Samples were prepared according to the provisions of GB 15358. The specimen into a clean container, sealed and marked with tags. Specimens shall be at room temperature
save.
NOTE. In the sample preparation procedure, it should prevent sample contamination.
|