 SN/T 2004.2-2005: Determination of lead, cadmium, chromium, electrical and electronic products Part 2: Flame atomic absorption spectrometry
 Status: Obsolete
 
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |  
			| SN/T 2004.2-2005 | English | 239 | Add to Cart | 2 days [Need to translate] | Determination of lead, cadmium, chromium, electrical and electronic products Part 2: Flame atomic absorption spectrometry | Obsolete | SN/T 2004.2-2005 |  
	 
       PDF similar to SN/T 2004.2-2005 
 Standard similar to SN/T 2004.2-2005GB 4943.1   GB 4943.21   GB 4793.1Basic data             | Standard ID | SN/T 2004.2-2005 (SN/T2004.2-2005) |           | Description (Translated English) | Determination of lead, cadmium, chromium, electrical and electronic products Part 2: Flame atomic absorption spectrometry |           | Sector / Industry | Commodity Inspection Standard (Recommended) |           | Classification of Chinese Standard | L09 |           | Classification of International Standard | 31.020 |           | Word Count Estimation | 6,613 |           | Date of Issue | 2005-07-18 |           | Date of Implementation | 2006-01-18 |           | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China |           | Summary | This standard specifies the electrical and electronic products, lead, cadmium and chromium by flame atomic absorption spectrometric method. This standard applies to electrical and electronic products in a variety of materials of lead, cadmium, chromium content. | SN/T 2004.2-2005: Determination of lead, cadmium, chromium, electrical and electronic products Part 2: Flame atomic absorption spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
 Determination of lead, cadmium, chromium, electrical and electronic products Part 2. Flame atomic absorption spectrometry
Book of the People's Republic of China Entry and Exit Inspection and Quarantine
SN/T 2004.2-2005
Determination of lead, cadmium and chromium in electrical and electronic products
Part 2. flame atomic absorption spectrometry
Released on July 17,.2005
Implementation of.2006-01-18
People's Republic
The General Administration of Quality Supervision, Inspection and Quarantine issued
 ForewordThis part is the second part of SN/T 2004.
Appendix A of this section is an informative annex.
This part is proposed and managed by the National Certification and Accreditation Administration.
This part is drafted by the Shenzhen Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, Jilin Province Entry-Exit Inspection and Quarantine
The bureau participated in the drafting.
The main drafters of this section. Liu Zhihong, Liu Li, Chen Mingyan, Guo Yan, Chen Yuyu, Li Ying, Li Hui, Wu Jingwu.
This section is the first industry standard for entry-exit inspection and quarantine.
SN/T 2004.2-2005
Determination of lead, cadmium and chromium in electrical and electronic products
Part 2. flame atomic absorption spectrometry1 ScopeThis section specifies methods for the determination of lead, cadmium and chromium in electrical and electronic products by flame atomic absorption spectrometry.
This section applies to the determination of lead, cadmium and chromium content in various materials of electrical and electronic products.2 Method summaryFor metal materials in electrical and electronic products, it is directly treated by conventional acid digestion; for other materials, closed high temperature pressure tanks are used -
Acid digestion treatment. Lead, cadmium, and chromium in the material are dissolved salts in the acid digestion solution. Digestion liquid into flame atomic absorption spectrometry
The measurement was carried out in a photometer.3 reagentsUnless otherwise stated, only reagents identified as analytically pure and above and distilled or deionized water or water of comparable purity were used in the analysis.
3.1 Nitric acid (HNO3). excellent grade pure.
3.2 Nitric acid solution (2+98).
3.3 30% hydrogen peroxide (H2O2). analytically pure.
3.4 Hydrochloric acid (HCl). excellent grade pure.
3.5 Hydrofluoric acid (HF). excellent grade pure.
3.6 Lead, cadmium, chromium standard solution. concentration of 100mg/L or 1000mg/L.4 Instruments and equipment4.1 Flame atomic absorption spectrophotometer. equipped with lead, cadmium and chromium hollow cathode lamps. See Appendix A for instrument operating conditions.
4.2 Oven. (0 ~.200) ° C, temperature control accuracy ± 5 ° C.
4.3 Pressure tank. Teflon liner and stainless steel tank jacket.
4.4 Electric heating plate.
4.5 Crushing equipment. chainsaws, grinders, metal cutting machines, lathes, etc.5 sample preparation5.1 polymer material
The sample is ground into a powder sample having a particle diameter of not more than 1 mm by a crushing device such as a chainsaw or a grinder.
5.2 Metal material
The sample is processed into a chip or a strip having a diameter of not more than 1 mm and a length of not more than 5 mm by a metal cutter, a lathe or the like.
5.3 Other materials
The preparation method is the same as 5.1.6 Analysis steps6.1 Sample digestion
6.1.1 Pressure tank digestion method
This method is applicable to the samples referred to in 5.1 and 5.3.
Weigh the sample (0.2 ~ 0.5) g, accurate to 1mg, placed in a pressure tank (4.3), add 8mL nitric acid (3.1), 2mL 30% peroxidation
SN/T 2004.2-2005
 
 Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 2004.2-2005_English be delivered?Answer: Upon your order, we will start to translate SN/T 2004.2-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of SN/T 2004.2-2005_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 2004.2-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries Question 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected] . In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.    |