HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

SN/T 1966-2007 English PDF

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 1966-2007English479 Add to Cart 4 days [Need to translate] Determination of chloramphenicol residues in aquatic product. Radio-receptor assay method Obsolete SN/T 1966-2007

PDF similar to SN/T 1966-2007


Standard similar to SN/T 1966-2007

SC/T 3053   GB 31602   SC/T 3505   SN/T 5652.2   SN/T 4851   SN/T 4483   

Basic data

Standard ID SN/T 1966-2007 (SN/T1966-2007)
Description (Translated English) Determination of chloramphenicol residues in aquatic product. Radio-receptor assay method
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard X20
Classification of International Standard 67.050
Word Count Estimation 12,171
Date of Issue 2007-08-06
Date of Implementation 2008-03-01
Quoted Standard GB/T 6682
Regulation (derived from) Accredidation-Technology-Letter [2015] No. 247
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the determination of chloramphenicol residues in aquatic products sample preparation and analysis of radiation receptor (Charm ��) method. This standard applies to chloramphenicol residues in aquatic products screening assays.

SN/T 1966-2007: Determination of chloramphenicol residues in aquatic product. Radio-receptor assay method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of chloramphenicol residues in aquatic product.Radio-receptor assay method Exit inspection and quarantine industry standard book People's Republic of China Detection of chloramphenicol residues in aquatic products Radioreceptor assay Posted 2007-08-06 2008-03-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. People's Republic of China Guangdong CIQ. The main drafters of this standard. phase Dapeng Chen snow, Zhanglin Tian, Chen Yanqin, Liang Xiyang, Luo Huiming, £ - Zhuang Yilin. This standard is the first release of the entry-exit inspection and quarantine industry standards. Detection of chloramphenicol residues in aquatic products Radioreceptor assay

1 Scope

This standard specifies the determination of chloramphenicol residues in aquatic products for sample preparation and radioreceptor assay (CharmⅡ) method. This standard applies to the screening assays of chloramphenicol residues in aquatic products.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. Laboratory use specifications and test methods GB/T 6682 Analysis

3 Sample preparation and preservation

3.1 Preparation of the sample All samples taken from a representative sample of not less than 500g, high-speed tissue masher mashing even the crushed sample is thoroughly mixed uniform. Loaded into a clean container, sealed and do identity. In the sample preparation process, should prevent sample contamination or the occurrence of the change of residue content. Samples for determining the number of bacteria can not exceed Over 106/g. 3.2 Sample preservation The sample was stored frozen at -18 ℃ below.

4 Determination

4.1 Principle Based assay is a competitive receptor immunoreactivity. After chloramphenicol residues in samples were extracted, and [3H] labeled chloramphenicol competition fine Chloramphenicol in bacterial cells specific receptors, chloramphenicol higher drug content in the sample, the more sites compete for binding, [3H] labeled chloramphenicol Biotin-binding sites of the less. After the reaction at a certain temperature, centrifuged, clear the [3H] labeled chloramphenicol unbound, scintillation fluid added after use LSC measurement sample of [3H] content cpm value (countperminute, that is, the number of pulses per minute). The lower the cpm value, The higher the sample chloramphenicol residues. 4.2 Reagents and materials 4.2.1 Water GB/T 6682 provided a water. The new kit batch performance monitoring shall be carried out before use. 1) CharmⅡ competitive receptor binding organization chloramphenicol test kit is provided by the trade name of the company's products Charm. This information is given The convenience of the user of this standard does not imply endorsement of the product. If other equivalent product has the same effect, you can use these equivalent product. 4.2.2.1 Competitive binding reagent. should be stored at -15 ℃ or less, up to 6h place at room temperature (15 ℃ ~ 25 ℃) under. 4.2.2.2 [3H] labeled chloramphenicol. should be stored at -15 ℃ or less, up to 6h place at room temperature (15 ℃ ~ 25 ℃) under.


Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information