|
US$169.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. RB/T 209-2017: Implementation guidelines for laboratory proficiency testing in the field of medical vectors Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| RB/T 209-2017 | English | 169 |
Add to Cart
|
3 days [Need to translate]
|
Implementation guidelines for laboratory proficiency testing in the field of medical vectors
| Valid |
RB/T 209-2017
|
PDF similar to RB/T 209-2017
Basic data | Standard ID | RB/T 209-2017 (RB/T209-2017) | | Description (Translated English) | Implementation guidelines for laboratory proficiency testing in the field of medical vectors | | Sector / Industry | Chinese Industry Standard (Recommended) | | Classification of Chinese Standard | A00 | | Word Count Estimation | 7,794 | | Date of Issue | 2017-01-03 | | Date of Implementation | 2017-08-01 | | Regulation (derived from) | State Accredidation Technology (2017) No.1 | | Issuing agency(ies) | National Certification and Accreditation Administration |
RB/T 209-2017: Implementation guidelines for laboratory proficiency testing in the field of medical vectors ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Guidance on the implementation of competency verification in the field of biomarkers for medical media)
ICS 03.120.20
A00
People's Republic of China certification and recognition of industry standards
Medical Media Biology Testing
Capability Verification Implementation Guide
Released on.2017-01-03
2017-08-01 implementation
China National Certification and Accreditation Administration issued
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is proposed and managed by the National Certification and Accreditation Administration.
This standard was drafted. Beijing Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, China National Accreditation Service for Conformity Assessment, Chinese
Shenzhen Entry-Exit Inspection and Quarantine Bureau of the Republic of China, China Academy of Inspection and Quarantine.
The main drafters of this standard. Tian Jie, Guo Huilin, Li Jianguang, Bian Yong, Liu Laifu, Tian Yin, Wu Xiaoyu, Gu Dayong, Zhang Xiaolong.
Medical Media Biology Testing
Capability Verification Implementation Guide
1 Scope
This standard gives the identification, implementation, results statistics, evaluation and reporting of medical vector species identification and pathogen verification activities.
The content of the report.
This standard is applicable to the implementation of medical media species identification and the detection of pathogen detection capabilities.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 27043 General requirements for conformity assessment
SN/T 1876 Medical Media Biological Specimen Collection, Production and Storage Procedures
Guide to Statistical Processing and Capability Evaluation of CNAS-GL02 Capability Verification Results
CNAS-GL03 Capability Verification Sample Uniformity and Stability Evaluation Guide
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Medical vector biology medicalvector
The transmission and storage of certain types of disease pathogens, and the ability to transmit pathogens from humans or other animals to human organisms.
Note. Medical vector organisms generally refer to medical rodents and medical arthropods that can transmit diseases, such as mosquitoes, flies, and mites.
3.2
Proficiency testing
Laboratory testing capabilities are determined using interlaboratory comparisons.
3.3
Interlaboratory comparison of interlaboratorycomparisons
A tissue that is tested by two or more laboratories for the same or similar test items, according to pre-specified conditions.
3.4
Proficiency test item proficiencytestitem
Samples, products, products, standards/samples, measurement standards, data sets or other information for proficiency testing.
3.5
Participant participant
A laboratory, organization, or individual that accepts proficiency testing items and submits results for evaluation by a proficiency testing provider.
3.6
Proficiency test provider proficiencytestingprovider
An organization that undertakes all the tasks involved in the design and implementation of a proficiency testing program.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of RB/T 209-2017_English be delivered?Answer: Upon your order, we will start to translate RB/T 209-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of RB/T 209-2017_English with my colleagues?Answer: Yes. The purchased PDF of RB/T 209-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|