NB/T 10184-2019: (Porcelain insulator unit product energy consumption limit)
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
NB/T 10184-2019English219 Add to Cart 3 days [Need to translate] (Porcelain insulator unit product energy consumption limit) Valid NB/T 10184-2019

PDF similar to NB/T 10184-2019


Standard similar to NB/T 10184-2019

GB 12021.9   GB 12021.6   GB 12021.4   NB/T 11234   NB/T 11147   NB/T 10933   

Basic data

Standard ID NB/T 10184-2019 (NB/T10184-2019)
Description (Translated English) (Porcelain insulator unit product energy consumption limit)
Sector / Industry Energy Industry Standard (Recommended)
Classification of Chinese Standard F01
Word Count Estimation 10,126
Date of Issue 2019-06-04
Date of Implementation 2019-10-01
Regulation (derived from) Natural Resources Department Announcement No. 7 of 2019
Issuing agency(ies) National Energy Administration

NB/T 10184-2019: (Porcelain insulator unit product energy consumption limit)

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
The norm of energy consumption per unit product of porcelain insulators ICS 27.010.10 F 01 NB Energy Industry Standards of the People's Republic of China The norm of energy consumption per unit product of porcelain insulator 2019- 06-04 released 2019-10-01 implementation Issued by National Energy Administration

Table of contents

Foreword...II 1 Scope...1 2 Normative references...1 3 Terms and definitions...1 4 Requirements...2 4.1 The limit value of comprehensive energy consumption per unit product of porcelain insulators of existing enterprises or production lines...2 4.2 The entry value of comprehensive energy consumption per unit product of porcelain insulators for newly-built enterprises or production lines...3 4.3 Advanced value of comprehensive energy consumption per unit product of porcelain insulators...3 4.4 Other 5 Statistical scope and calculation method...3 5.1 Statistical scope...3 5.2 Statistical methods...4 5.3 Calculation method...4 5.4 Conversion of standard coal...4 6 Energy-saving management and measures...4 6.1 Energy-saving basic management...4 6.2 Energy-saving technology and management...4 Appendix A (informative appendix) Various energy conversion coefficients and energy consumption working fluid conversion coefficients...6

Foreword

Drafting. This standard was proposed by China Electrical Equipment Industry Association. This standard is under the jurisdiction of the National Insulator Standardization Technical Committee (SAC/TC 80). The main drafting organizations of this standard. Suzhou Electric Porcelain Factory Co., Ltd., Xi’an High Voltage Electrical Apparatus Research Institute Co., Ltd., China National Electric Industry Association Insulator Lightning Arrester Branch, China Qiyuan Engineering Design and Research Institute Co., Ltd., Dalian Electric Porcelain Group Power Transmission Material Co., Ltd., NGK Tangshan Electric Porcelain Co., Ltd., Sinoma Jiangxi Electric Porcelain Electric Co., Ltd., Liling Huaxin Electric Porcelain Technology Co., Ltd., Xi'an Xidian High Piezoelectric Porcelain Co., Ltd., Hunan Yangdong Dian Porcelain Electric Co., Ltd., Shandong Zibo Electric Porcelain Factory Co., Ltd. Participated in the drafting of this standard. Electrical Porcelain Industry Administration of Luxi County, Pingxiang City, Jiangxi Province, Fushun Electrical Porcelain Manufacturing Co., Ltd., Tangshan High Voltage Porcelain Co., Ltd., Inner Mongolia Jingcheng High Voltage Insulator Co., Ltd., Pingxiang Best Electric Porcelain Co., Ltd., Pingxiang Huawei Electric Porcelain Technology Co., Ltd. Co., Ltd., Chongqing Pigeon Brand Electric Porcelain Co., Ltd., Henan Irdeto Power Equipment Co., Ltd., Henan Zhonglian Hongxing Electric Porcelain Co., Ltd. Company, Fushun Gaoke Electric Porcelain Manufacturing Co., Ltd., Zigong Red Star High Voltage Electric Porcelain Co., Ltd., Mudanjiang North High Voltage Electric Porcelain Co., Ltd. Division. The main drafters of this standard. Lu Zhou, Yao Junrui, Zhang Jigang, Li Yueming, Meng Dechen, Wang Yunpeng, Yang Ming, Yang Xuefeng, Dong Gang, Shen Yunfeng, Xu Xinlin, Wang Hong, Wang Xingfang, Wei Peng. Participating drafters of this standard. Liu Chunlei, Tang Xiaozhong, Liu Zhanming, Zhang Yaochen, Liu Jiasheng, Hu Wenhua, Tao Shi, Liu Zhiyong, Zeng Weiguang, Song Zhenhui, Bi Shaochuan, Liu Weili, Zhao Hui. The norm of energy consumption per unit product of porcelain insulator

1 Scope

This standard specifies the requirements, statistical scope and calculation method of energy consumption per unit product of high-voltage porcelain insulators (hereinafter referred to as energy consumption), Energy-saving management and measures. This standard is applicable to the calculation and evaluation of the normal production energy consumption of porcelain insulator manufacturing enterprises, as well as to the new porcelain insulator manufacturing enterprises or production Calculation and evaluation of energy consumption of the line. Note. It is generally considered that the actual output reaches 80% or more of the designed capacity as normal production. This standard can also be used to assess the responsibility for energy-saving targets of porcelain insulator manufacturers, eliminate and resolve outdated production capacity, and fixed asset investment projects Energy conservation assessment and review, energy conservation supervision, etc.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 2589-2008 General Rules for Comprehensive Energy Consumption Calculation GB/T 2900.8-2009 Electrical terminology insulator GB/T 12723-2013 General rules for the compilation of energy consumption per unit product GB 17167-2006 General rules for the provision and management of energy measuring instruments for energy-consuming units

3 Terms and definitions

GB/T 2589-2008, GB/T 2900.8-2009 and GB/T 12723-2013 defined, and the following terms and definitions apply to this standard quasi. 3.1 Comprehensive energy consumption of porcelain insulator products During the statistical reporting period, the actual amount of energy consumed and lost by the porcelain insulator production system shall be calculated in accordance with GB/T 2589. The calculation method and unit are respectively converted to the sum. Note. This does not include the energy consumed by the construction of infrastructure technological transformation projects, the production and utilization of non-ceramic insulators in the production area, and the energy output. 3.2 Comprehensive energy consumption per unit product of porcelain insulator The ratio between the comprehensive energy consumption of porcelain insulator products and the quality of qualified porcelain insulator products produced by enterprises during the statistical reporting period is generally based on kgce/t said. Note. The quality of qualified porcelain insulators includes the quality of the end fittings permanently fixed on the porcelain and the quality of the corresponding glue-mounted materials. 3.3 Low calorific value net calorific value The total amount of heat emitted by a unit mass of fuel when it is completely burned is the calorific value after deducting the latent heat of vaporization of water vapor in the flue gas.

4 requirements

4.1 The limit value of comprehensive energy consumption per unit product of porcelain insulators of existing enterprises or production lines The limit value of comprehensive energy consumption per unit product of porcelain insulators of existing enterprises or production lines shall meet the requirements of Table 1. 4.2 The entry value of comprehensive energy consumption per unit product of porcelain insulators of newly-built enterprises or production lines The comprehensive energy consumption per unit product of porcelain insulators of newly-built enterprises or production lines shall meet the requirements of Table 2. 4.3 Advanced value of comprehensive energy consumption per unit product of porcelain insulators The advanced value of comprehensive energy consumption per unit product of porcelain insulator is shown in Table 3. 4.4 Other Cylinder head structure disc-shaped suspension porcelain insulators and inorganic bonded hollow porcelain insulators, the comprehensive energy consumption per unit limit value, access value and advanced The values are correspondingly increased by 20% compared to Table 1, Table 2 and Table 3. According to the national regulations, the energy consumption limit for heating areas in winter is calculated at an increase of 3% per heating month. In the production of multi-variety products, the specified value is calculated by weighting the actual output of the classified product in the total output.

5 Scope and calculation method

5.1 Statistical scope The statistical scope of the comprehensive energy consumption of porcelain insulators includes. raw material crushing, raw material mixing, raw material transportation, slurry preparation, slurry screening, and slurry In addition to iron, slurry filter press or spray drying, coarse mud smelting, stale mud, vacuum smelting and blank extrusion or blank pressing, blank drying, light blank Forming (compact and trimming), sand making, dry blank, glaze sanding, firing, cutting and grinding of porcelain, bonding of porcelain, porcelain and end The production process of assembly parts applying buffer layer, ceramic parts glued end assembly parts, product maintenance, finished product packaging, process transfer, etc., as well as all auxiliary and The energy consumed by the subsidiary production process. 5.2 Statistical methods The energy consumption of the main production system shall be classified according to the actual measurement statistics in Table 1 to Table 3.The equipment and management of energy measuring instruments shall comply with GB 17167 Regulations. The energy consumption of the auxiliary production system and the auxiliary production system can be shared and counted. The output of qualified products is classified and counted according to product categories. can There should be no re-counting or under-counting in the statistics of consumption and production of qualified products. 5.3 Calculation method The calculation of product comprehensive energy consumption and unit product comprehensive energy consumption shall comply with GB/T 2589-2008. The comprehensive energy consumption of the product is calculated according to formula (1). 5.4 Conversion of standard coal The various energy consumed should be converted into a unified standard coal based on the calorific value. The calorific value of the fuel is based on the average low of the fuel measured during the reporting period of the company Calorific value calculation. If the actual measurement is unconditional or the routine analysis is still difficult at present, the various energy sources given in Table A.1 of this standard can be converted into standard coal The coefficient is converted to standard coal. Other energy-consuming working fluids are converted into standard coal using the conversion coefficient given in Table A.2 of this standard. 6 Energy-saving management and measures 6.1 Energy-saving basic management Porcelain insulator manufacturers should reasonably configure and use energy measuring instruments according to their actual conditions and the classification statistics requirements of this standard. And meet the requirements of GB 17167, establish and improve the energy monitoring, statistics, internal audit, assessment, supervision, rewards and punishment systems and conform to this standard According to the energy consumption statistics system, strengthen the controlled management of the whole process, determine and implement comprehensive energy consumption assessment indicators per unit of product. 6.2 Energy-saving technology and management Porcelain insulator manufacturers should actively promote the use of new energy-saving technology, such as energy-saving raw material processing technology, energy-saving drying technology, high-speed Isothermal roasting technology, waste heat utilization technology, etc. Newly built, renovated and expanded porcelain insulator production enterprises should reach economic operation scale, and the configured general energy-consuming equipment should reach the corresponding energy-consuming equipment. The requirements of the energy-saving evaluation value in the efficiency standard. Porcelain insulator manufacturers should make their general energy-consuming equipment meet the requirements of the economic operation standard of the corresponding energy-consuming equipment and reach the economic operation state. Porcelain insulator manufacturers should take effective measures to ensure the normal, stable and continuous operation of the production system. AA

Appendix A

(Informative appendix) Various energy conversion coefficients and energy consumption working fluid conversion coefficients The coefficients of various energy converted into standard coal are shown in Table A.1.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of NB/T 10184-2019_English be delivered?

Answer: Upon your order, we will start to translate NB/T 10184-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of NB/T 10184-2019_English with my colleagues?

Answer: Yes. The purchased PDF of NB/T 10184-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information