US$369.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. LY/T 2579-2016: Forest fire insurance monitor station technical specification Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| LY/T 2579-2016 | English | 369 |
Add to Cart
|
3 days [Need to translate]
|
Forest fire insurance monitor station technical specification
| Valid |
LY/T 2579-2016
|
PDF similar to LY/T 2579-2016
Basic data | Standard ID | LY/T 2579-2016 (LY/T2579-2016) | | Description (Translated English) | Forest fire insurance monitor station technical specification | | Sector / Industry | Forestry Industry Standard (Recommended) | | Classification of Chinese Standard | B65 | | Classification of International Standard | 65.020.99 | | Word Count Estimation | 16,130 | | Date of Issue | 2016-01-18 | | Date of Implementation | 2016-06-01 | | Quoted Standard | QX/T 1; QX 30 | | Regulation (derived from) | ?State Forestry Bureau Announcement 2016 No.1 | | Issuing agency(ies) | State Forestry Administration | | Summary | This standard specifies the technical performance, site selection, installation and maintenance requirements of the Forest Fire Safety Station. This standard applies to the production, inspection, installation, use, acceptance and maintenance of forest fire monitoring stations. |
LY/T 2579-2016: Forest fire insurance monitor station technical specification---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Forest fire insurance monitor station technical specification
ICS 65.020.99
B65
People's Republic of China Forestry Industry Standard
Forest fire risk monitoring station technical specifications
Released on.2016-01-18
2016-06-01 implementation
State Forestry Administration released
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard was proposed by the Office of the National Forest Fire Command.
This standard is under the jurisdiction of the National Forest Fire Protection Standardization Technical Committee (SAC/TC523).
This standard was drafted. Heilongjiang Provincial Forest Protection Research Institute, Forest Protection Early Warning and Monitoring Information Center of the State Forestry Administration, Changchun Huaxinqi
Image Technology Co., Ltd., Northeast Forestry University, Changchun Huasheng Tianxun Technology Co., Ltd., Institute of Forest Ecology, Environment and Protection, Chinese Academy of Forestry.
The main drafters of this standard. Wang Lifu, Wang Xinyan, Jiang Yuexin, Yao Shuai, Liu Xin, Liu Hengxu, Yan Yingxin, Fu Ning, Li Lihua, Zhao Fengjun,
Wang Mingyu, Zhang Lin.
Forest fire risk monitoring station technical specifications
1 Scope
This standard specifies the technical performance, site selection, installation and maintenance requirements of forest fire risk monitoring stations.
This standard applies to the production, inspection, installation, use, acceptance and maintenance of forest fire risk monitoring stations.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
QX/T 1 II automatic weather station
QX30 automatic weather station field lightning protection technical specification
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Forest fire insurance forestfirehazard
The degree of risk of forest fires in a given area. Nature, society mainly caused by forest fires and forest fires
It will be composed of risk factors.
3.2
Forest fire risk monitoring station forestfireinsurancemonitorstation
Customized equipment and stations customized for forest fire risk warning monitoring that automatically observe and report meteorological factors related to forest fire risks.
3.3
Forest fire insurance information collection management platform informationcolectionandmanagementplatformofforestfire
Collect and manage forest fire risk monitoring stations, forest fire risk factor collection stations, and hand-held forest fire risk monitoring stations for national and provincial forest fire risk warning centers
Meteorological observation information, and management platform for operation status monitoring and remote configuration and data distribution. Composed of client and server
(B/S structure), based on the map of the day, to achieve data collection, data display, data query, statistical analysis, equipment management, user management, etc.
Features.
4 Technical requirements
4.1 Composition
Forest fire risk monitoring stations mainly include.
a) Meteorological element sensors. including rainfall, temperature, humidity, wind direction, wind speed sensor;
b) data collector. including meteorological element converters, controllers and interfaces;
c) Communication terminal. including GPRS/CDMA or other long-distance communication terminals (such as Beidou);
d) Power supply. including charging controller, solar panel, battery;
e) Accessories. including connectors, lightning arresters, instrument cases, bases, brackets and fences.
|