HOME   Cart(12)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

LY/T 1152-2010 English PDF

US$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
LY/T 1152-2010: Forestry machinery. Incubator for forest tree seed
Status: Valid

LY/T 1152: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
LY/T 1152-2010English209 Add to Cart 3 days [Need to translate] Forestry machinery. Incubator for forest tree seed Valid LY/T 1152-2010
LY/T 1152-1994English199 Add to Cart 2 days [Need to translate] (Tree Seed germination is light. Technical conditions) Obsolete LY/T 1152-1994

PDF similar to LY/T 1152-2010


Standard similar to LY/T 1152-2010

LY/T 3022   LY/T 1346   SL 470   LY/T 2158   LY/T 1486   LY/T 1618   

Basic data

Standard ID LY/T 1152-2010 (LY/T1152-2010)
Description (Translated English) Forestry machinery. Incubator for forest tree seed
Sector / Industry Forestry Industry Standard (Recommended)
Classification of Chinese Standard B95
Classification of International Standard 65.060.80
Word Count Estimation 8,819
Date of Issue 2010-02-09
Date of Implementation 2010-06-01
Older Standard (superseded by this standard) LY/T 1152-1994; LY/T 1153-1994
Quoted Standard GB/T 191; GB 2772; GB 4706.1; GB/T 13384; GB/T 15479; JB/T 9512
Regulation (derived from) Industry standard filing Notice 2010 No. 5 (No. 125 overall)
Issuing agency(ies) State Forestry Administration
Summary This standard specifies the tree seed incubator (hereinafter referred to as the incubator) the use of environmental conditions, technical requirements, test methods, inspection rules and signs, packaging, storage and transportation. This standard applies to regulate temperature, humidity and the use of artificial light incubator

LY/T 1152-2010: Forestry machinery. Incubator for forest tree seed

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Forestry machinery.Incubator for forest tree seed ICS 65.060.80 B95 People's Republic of China Forestry Industry Standard Replacing LY/T 1152-1994, LY/T 1153-1994 Forestry machinery tree seed incubator Released on.2010-02-09 2010-06-01 implementation State Forestry Administration released

Foreword

This standard is for LY/T 1152-1994 "Technical conditions for forest seed light germination" and LY/T 1153-1994 "forest seed Revision of the Light Germination Test Method and combine the two standards. This standard cancels and replaces LY/T 1152-1994 and LY/T 1153-1994 from the date of implementation. Compared with LY/T 1152-1994 and LY/T 1153-1994, the main changes are as follows. 1) The scope of Chapter 1 is changed from “Applicable to internal heat-type forest seed light germination device capable of automatic water absorption and ventilation” to “Applicable to controllable Temperature, humidity and incubator with artificial light source"; 2) Revised the normative reference documents; 3) Increased requirements for the use environment; 4) Increased requirements for noise, insulation resistance and stability; 5) Revised product structure and appearance requirements; 6) Modified the test method; 7) Increased the principle of judgment. This standard is proposed and managed by the National Forestry Machinery Standardization Technical Committee. This standard is drafted by. Liaoning Provincial Forestry Department Information Center. Participated in the drafting of this standard. Liaoning Provincial Plant Protection Station, Qianjiang Instrument Equipment Factory, Liaoning Provincial Forestry Work Station, Liaoning Forestry Professional Technical College, Liaoning Provincial Forestry Department Seedling Station. The main drafters of this standard. Chang Ying, He Lili, Wang Wei, Unit Road, Feng Wei, Zeng Hui, Yang Yanqin, Cai Liping, Yao Fei. The previous versions of the standards replaced by this standard are. ---LY/T 1152-1994; ---LY/T 1153-1994. Forestry machinery tree seed incubator

1 Scope

This standard specifies the environmental conditions, technical requirements, test methods and inspection rules for the use of forest seed incubators (hereinafter referred to as incubators). And marking, packaging, storage and transportation. This standard applies to incubators that can regulate temperature, humidity and artificial light sources.

2 Normative references

The terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all Modifications (not including errata content) or revisions do not apply to this standard, however, parties to agreements based on this standard are encouraged to study Is it possible to use the latest version of these files? For undated references, the latest edition applies to this standard. GB/T 191 packaging storage and transportation pictorial signs (GB/T 191-2008, ISO 780.1997, MOD) GB 2772 forest seed inspection procedures GB 4706.1 Safety of household and similar electrical appliances - Part 1. General requirements [GB 4706.1-2005, IEC 60335-1. 2004 (Ed4.1), IDT] General technical conditions for GB/T 13384 mechanical and electrical product packaging GB/T 15479 Industrial automation instrumentation insulation resistance, insulation strength technical requirements and test methods JB/T 9512 Determination of noise power level of climatic environment test equipment and test chamber

3 Use of environmental conditions

The environmental conditions for the use of the incubator are. a) room temperature. 5 ° C ~ 40 ° C; b) Relative humidity. ≤90%; c) Air pressure. 86kPa ~ 106kPa; d) Power supply voltage. 220V±22V or 380V±38V; power frequency. 50Hz±0.5Hz; e) Water pressure. 0.2MPa~0.3MPa; water temperature. < 30°C; f) no strong electromagnetic field around; g) vibration and corrosive substances with no influence on the surrounding; h) No direct sunlight or other sources of cold heat.

4 Technical requirements

4.1 Product performance 4.1.1 Temperature adjustable range The incubator should have a variable temperature control function, and the temperature can be adjusted from 5 °C to 40 °C. 4.1.2 Humidity adjustable range The incubator should have the functions of humidity measurement, humidification and humidity control, and the relative humidity should be adjustable from 50% to 100%. 4.1.3 Temperature fluctuation The temperature fluctuation of the incubator should meet the requirements of GB 2772 and should not exceed ±1 °C.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of LY/T 1152-2010_English be delivered?

Answer: Upon your order, we will start to translate LY/T 1152-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of LY/T 1152-2010_English with my colleagues?

Answer: Yes. The purchased PDF of LY/T 1152-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version LY/T 1152-2010?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version LY/T 1152-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information