US$339.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 662-2005: Verification regulation of paramagnetic oxygen analyzer Status: Valid JJG 662: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 662-2005 | English | 339 |
Add to Cart
|
3 days [Need to translate]
|
Verification regulation of paramagnetic oxygen analyzer
| Valid |
JJG 662-2005
|
JJG 662-1990 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Verification Regulation of Thermo-Magnetic Oxygen Analyzers
| Obsolete |
JJG 662-1990
|
PDF similar to JJG 662-2005
Basic data Standard ID | JJG 662-2005 (JJG662-2005) | Description (Translated English) | Verification regulation of paramagnetic oxygen analyzer | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A61 | Classification of International Standard | 17 | Word Count Estimation | 13,191 | Date of Issue | 2005-04-28 | Date of Implementation | 2005-10-28 | Older Standard (superseded by this standard) | JJG 662-1990 | Summary | This standard applies to paramagnetic oxygen (including thermal-magnetic oxygen, oxygen pressure type magnetic, magneto mechanical oxygen) analyzer initial verification, testing and use of follow-up inspection, |
JJG 662-2005: Verification regulation of paramagnetic oxygen analyzer---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification regulation of paramagnetic oxygen analyzer
National Metrology Verification Regulations of the People's Republic
Paramagnetic oxygen analyzer
Released on.2005-04-28
2005-10-28 implementation
The General Administration of Quality Supervision, Inspection and Quarantine issued
Replacing JJG 662-1990
This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on April 28,.2005, and
Implemented on October 28,.2005.
Focal Point. National Physical and Chemical Metrology Technical Committee
Main drafting unit. National Standards Research Center
Participated in the drafting unit. Quality Inspection Bureau of Ningbo Quality and Technical Supervision Bureau
This procedure entrusts the National Physical and Chemical Metrology Technical Committee to explain
The main drafters of this procedure.
Li Chunxi (National Reference Materials Research Center)
Participate in the drafters.
Guan Yihe (Ningbo Quality and Technical Supervision Bureau Quality Inspection Institute)
Yu Dengyu (National Standards Research Center)
Zhang Peizhuang (National Standards Research Center)
table of Contents
1 Scope (1)
2 Overview (1)
3 Metrological performance requirements (1)
3.1 Instrument level and indication error limits (1)
3.2 Repeatability (1)
3.3 Response time (1)
3.4 Stability (1)
3.4.1 Zero drift (1)
3.4.2 Indication drift (1)
4 General technical requirements (2)
4.1 Appearance and Functional Inspection (2)
4.2 Insulation resistance (2)
4.3 Dielectric strength (2)
5 Control of measuring instruments (2)
5.1 Verification conditions (2)
5.2 Verification project (3)
5.3 Verification method (3)
5.4 Processing of verification results (5)
5.5 Verification cycle (5)
Appendix A Format of the certificate and the result of the verification result (6)
Appendix B Verification Record Format (7)
Paramagnetic oxygen analyzer verification procedure
1 Scope
This procedure applies to the first time for paramagnetic oxygen (including thermomagnetic oxygen, magnetic pressure oxygen, magnetic mechanical oxygen) analyzers.
Verification, follow-up verification and in-use inspection.
2 Overview
Thermomagnetic oxygen analyzer, magnetic pressure oxygen analyzer, magnetic mechanical oxygen analyzer are usually online detection (or supervision)
Meter) for continuous automatic analysis of the oxygen content of the gas. Its working principle is based on the paramagnetism of oxygen. Use oxygen
Is attracted in the magnetic field to produce corresponding thermomagnetic convection (thermomagnetic), pressure difference (magnetic pressure), density gradient (magnetic
Mechanical), and through the detection of components to convert thermomagnetic convection, pressure difference, density gradient into electrical signals, thereby achieving
The measurement of the oxygen concentration in the gas is measured.
3 Metrological performance requirements
3.1 Instrument level and indication error limits
For different classes of instruments, the corresponding indication error limits shall be in accordance with Table 1 within the range of their ranges.
Table 1 Instrument level and indication error limits
Instrument level indication error limit /%FS
1.0 ± 1.0
1.5 ± 1.5
2.5 ± 2.5
5.0 ± 5.0
3.2 Repeatability
Under the same conditions, the same standard gas is measured 6 times, and the relative standard deviation should be no more than the corresponding indication.
The error limit is 1/2 of the absolute value.
3.3 Response time
Thermomagnetic oxygen analyzer. no more than 50s;
Magnetic pressure oxygen analyzer, magnetic mechanical oxygen analyzer. no more than 30s.
3.4 Stability
3.4.1 Zero drift
The instrument runs continuously for 4 hours, and the zero drift should not exceed the indication error limit.
3.4.2 indication drift
The instrument is continuously operated for 4h, and the indication value drift should not exceed the indication error limit.
For the first run of the instrument, the zero running time and the continuous running time of the indication drift should refer to the instrument manual.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 662-2005_English be delivered?Answer: Upon your order, we will start to translate JJG 662-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 662-2005_English with my colleagues?Answer: Yes. The purchased PDF of JJG 662-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 662-2005?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 662-2005 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|