HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

JJG 593-2016 English PDF

US$529.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 593-2016: Thermoluminescence Dosimetry Systems Used in Personal and Environmental Monitoring for X and γ Radiation
Status: Valid

JJG 593: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 593-2016English529 Add to Cart 5 days [Need to translate] Thermoluminescence Dosimetry Systems Used in Personal and Environmental Monitoring for X and γ Radiation Valid JJG 593-2016
JJG 593-2006English999 Add to Cart 5 days [Need to translate] Verification Regulation of Thermoluminescence Dosimetry Systems Used in Personal and Environmental Monitoring for X and Gamma Radiation Obsolete JJG 593-2006
JJG 593-1989English479 Add to Cart 4 days [Need to translate] Verification Regulation of Thermoluminescence Dosimetry Assembly for Personal Monioring of X or γ Radiation Obsolete JJG 593-1989

PDF similar to JJG 593-2016


Standard similar to JJG 593-2016

GB/T 3222.1   JJG 188   JJF 1396   JJG 852   JJG 377   JJG 589   

Basic data

Standard ID JJG 593-2016 (JJG593-2016)
Description (Translated English) Thermoluminescence Dosimetry Systems Used in Personal and Environmental Monitoring for X and �� Radiation
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A58
Word Count Estimation 23,248
Date of Issue 2016-11-30
Date of Implementation 2017-05-30
Older Standard (superseded by this standard) JJG 593-2006
Regulation (derived from) State Administration of Quality Supervision, Inspection and Quarantine Notice No.119 of 2016
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine

JJG 593-2016: Thermoluminescence Dosimetry Systems Used in Personal and Environmental Monitoring for X and γ Radiation


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Thermoluminescence Dosimetry Systems Used in Personal and Environmental Monitoring for X and γ Radiation National Metrological Verification Regulation of the People's Republic of China Individual and environmental monitoring with X, gamma radiation thermoluminescence dose measuring system 2016-11-30 release 2017-05-30 implementation State Administration of Quality Supervision, Inspection and Quarantine issued Personal and environmental monitoring with X, gamma radiation Verification procedure of thermoluminescence dose measurement system VerificationRegulation ofThermoluminescence Replacing JJG 593-2006 Unit. National Diameter Radiation Metrology Technical Committee Drafting unit. China Testing Technology Research Institute Shanghai Institute of Metrology and Testing Technology This procedure is entrusted to the National Council on Ionizing Radiation Metrology The main drafters of this procedure. Liu Zhihong (China Testing Technology Research Institute) Chen Jianxin (Shanghai Institute of Metrology and Testing Technology) Li Jing (China Testing Technology Research Institute) Participate in the drafters. But Yu Juan (China Test Technology Research Institute) Yu Bing (China Institute of Testing Technology)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 terms and units of measurement (1) 3.1 Terms (1) 3.2 Units of measurement (2) 4 Overview (2) 5 Metrological performance requirements (3) 6 General technical requirements (4) 6.1 Dosimeter (4) 6.2 Reader (4) 7 Metering device control (4) 7.1 Test conditions (4) 7.2 Verification Project (5) 7.3 Verification method (5) 7.4 Processing of test result (8) 7.5 Test cycle (8) Appendix A Recommended Verification Record Format (9) Appendix B Verification Certificate Page Format (10) Appendix C Results Notice Page Format (11) Appendix D Conversion coefficient of air to kinetic energy to dose equivalent (12) Appendix EX Characteristics and Conditions of Reference Radiation (14) Appendix F Confidence Interval (16)

Introduction

The procedures to GB/T 10264-2014 "personal and environmental monitoring with thermoluminescence dose measurement system" as the basis, According to JJF1002-2010 "national measurement procedures for the preparation of rules" requirements, the JJG 593-2006 repair Set, compared with JJG 593-2006 version, in addition to editorial changes, the main changes are as follows. --- The name of the test procedure is defined by "Personal and Environmental Monitoring with X, γ Radiation Thermoluminescence Dose Measurement (Device) "Changed to" personal and environmental monitoring with X, γ radiation thermoluminescence dose measurement system "; --- "test project" added a "coefficient of variation" and its corresponding content; The previous versions of this order are released as follows. --- JJG 593-2006; JJG 593-1989 and JJG 698-1990. Test procedures for X and γ radiation thermoluminescence dosimetry systems for personal and environmental monitoring

1 Scope

This procedure applies to measuring the dose range of 0.01mSv ~ 10Sv, the energy range of 30keV ~ 1.5MeV (10) and the surrounding dose equivalent H * (10), and the energy range is 8keV ~ 250keV personal dose equivalent Hp (0.07) thermoluminescence dose measurement system for the first time, follow-up Check and check in use. This procedure does not apply to devices equipped with an extremist dosimeter for personal monitoring and does not apply to pulse X, gamma radiation Radiation, beta radiation, neutron radiation and cosmic ray radiation devices.

2 reference file

This procedure refers to the following documents. Thermoluminescence dosimetry systems for personal and environmental monitoring GB/T 12162.1 X and γ reference radios for calibrating dosimeters and dosimetry instruments and determining their energy response Part 1. Radiation characteristics and methods of production GB/T 12162.2 X and γ reference radios for calibrating dosimeters and dosimetry instruments and determining their energy response Part 2. Radiation protection with energy ranges from 8 keV to 1.3 MeV and 4 MeV to 9 MeV Radiation dose determination GB/T 12162.3 X and γ reference radiation for calibrating dosimeters and dosimetry instruments and determining their energy response Part 3. Calibration of place dosimeters and personal dosimeters and determination of their energy response and angular response IEC 62387-1..2007 Radiation protection instruments Passive integral dose measurement for environmental and personal monitoring System - Part 1. General characteristics and performance requirements (Radiationprotectioninstrumentation - Passive integratingdosimetrysystemsforenvironmentalandpersonalmonitoring-Part 1. Gen- eralcharacteristics andperformancerequirements) For dated references, only the dated edition applies to this rule, and references that are not dated , The latest version (including all amendments) applies to this procedure.

3 terms and units of measurement

3.1 terminology 3.1.1 Thermoluminescence (TL) A substance that exhibits a light that emits light when irradiated with ionizing radiation or ultraviolet rays. 3.1.2 thermoluminescent detector (referred to as detector) thermoluminescent (TL) detector A certain amount of thermoluminescent material, or the material and other non-luminescent material by a certain weight ratio of the composition of a definite Volume, shape or size of the mixture, the detector is absorbed by the radiation and store part of the energy of the radiation, in the measurement process This part of the energy is released in the form of light when the detector is heated.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 593-2016_English be delivered?

Answer: Upon your order, we will start to translate JJG 593-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 593-2016_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 593-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 593-2016?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 593-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.