HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

JJG 2009-2016 English PDF

US$229.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 2009-2016: RF and Microwave Power Measuring Instruments
Status: Valid

JJG 2009: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 2009-2016English229 Add to Cart 3 days [Need to translate] RF and Microwave Power Measuring Instruments Valid JJG 2009-2016
JJG 2009-1987English239 Add to Cart 3 days [Need to translate] Verification scheme of RF and microwave power measuring instruments Obsolete JJG 2009-1987

PDF similar to JJG 2009-2016


Standard similar to JJG 2009-2016

JJF 1234   JJF 1396   JJG 376   JJF 2016   JJF 2009   JJF 2009   

Basic data

Standard ID JJG 2009-2016 (JJG2009-2016)
Description (Translated English) RF and Microwave Power Measuring Instruments
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A56
Classification of International Standard 17.220
Word Count Estimation 10,129
Date of Issue 2016-11-30
Date of Implementation 2017-05-30
Older Standard (superseded by this standard) JJG 2009-1987
Quoted Standard JJF 1001; JJF 1188; JJF 1059.1
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard is applicable to the transmission of radio frequency and microwave power, including the transmission of radio frequency and microwave power from the radio frequency and microwave power measurement standard through the measurement standard to the working measuring instrument, the amount of transmission method and the measurement of the transmission capacity. In carrying out the calibration, but also as a basis for the value of traceability.

JJG 2009-2016: RF and Microwave Power Measuring Instruments

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
RF and Microwave Power Measuring Instruments National People's Republic of China Metrological Verification System Radio frequency and microwave power measuring instruments 2016-11-30 release 2017-05-30 implementation State Administration of Quality Supervision, Inspection and Quarantine issued Radio frequency and microwave power measuring instruments Verification system table Replacing JJG 2009-1987 Coordinate Unit. National Radio Measurement Technology Committee The main drafting unit. China Institute of Metrology Participated in the drafting unit. China Aerospace Science and Technology Corporation five homes Xi'an Branch The system is commissioned by the National Radio Measurement Technology Committee to explain The main system of the test system. Cui xiaohai (China Institute of Metrology) Li Yong (China Institute of Metrology) Jia Chao (China Institute of Metrology) Participate in the drafters. Cai Xiaohong (China Aerospace Science and Technology Corporation five homes Xi'an Branch) Wang Fu Tao (China Aerospace Science and Technology Corporation five homes Xi'an Branch)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 measurement basis (1) 3.1 Name and magnitude (1) 3.2 Power Benchmark Uncertainty (1) 3.3 Transfer method (1) 4 Metrological standards (1) 4.1 Name (1) 4.2 Volatility and Uncertainty (2) 4.3 Transfer method (3) 5 Work measuring instruments (3) 5.1 Name and measurement range of typical work measuring instruments (3) 5.2 Power deviation of work measuring instruments (3) 6 RF and microwave power measurement equipment test system block diagram (4)

Introduction

The test system table is based on JJF1001-2011 "General measurement terms and definitions" and JJF1104-2003 "country JQG2009-1987 is based on the preparation of the rules for the preparation of the system. And JJG 2009-1987 "radio frequency and microwave power measurement instrument test system table" compared to the main content is like Under change. --- According to the existing national radio frequency and microwave power reference value transmission capacity, will test system table work The upper limit of the frequency is extended to 75GHz, and the power range of the measurement standard and the working metering device is extended to 500W. --- the original three sets of power reference band narrow, complex operation, not easy program control, is no longer used. Original system Table 3cm power base using calorimeter technology, the new four sets of power benchmarks are used microcalorimeter technology, after Than the former has the advantages of simple operation, low uncertainty. In view of the current international comparison, the domestic value of the most in the transmission High power level of 10mW, and the measurement standard in the 10mW power level with a stable value, measurement of high signal to noise ratio , The upper limit of the power level of the four sets of new power references is set to 10 mW. For more than 10mW Power level, the measurement department at all levels can be based on the situation, the use of range expansion method, to solve their own. --- refer to the China Institute of Metrology published National Calibration and Measurement Capability (CMC) table to adjust the part Frequency band technical indicators. In the measurement standard transfer method, the complicated method of power equation method and reflectometer method is deleted. The test system table of the previous release. --- JJG 2009-1987. Radio frequency and microwave power measuring instrument verification system table

1 Scope

The test system table applies to radio frequency and microwave power transfer, including radio frequency and microwave power from the radio frequency and Microwave power measurement basis through the measurement standard to the work of measuring instruments of the transfer relationship, the value of the transfer method and the value of transmission When the measurement capacity. In carrying out the calibration, but also as a basis for the value of traceability.

2 reference file

Standard Terminology and Definitions for JJF1001 JQF1188 Terminology and definitions of radio metrology nouns Evaluation and Representation of Measurement Uncertainty in JJF1059.1 Where the date of the reference file, only the date of the version applies to the system table, all do not note the date of the reference text , The latest version (including all modifications) applies to this system.

3 measurement basis

3.1 name and value Radio frequency and microwave power (hereinafter referred to as power) measurement benchmark (hereinafter referred to as benchmark), including coaxial power reference group And the waveguide power reference group. The magnitude of the power reference reproduction is the effective efficiency of the RF and microwave thermistor mounts. 3.2 Power Benchmark Uncertainty 3.2.1 Coaxial power reference group N-type coaxial power reference, frequency. 0.01GHz ~ 18GHz, power. 1mW ~ 10mW, uncertain 0.1% (k = 2). 3.2.2 Waveguide power reference group WR-28 waveguide power reference, frequency. 26.5GHz ~ 40GHz, power. 1mW ~ 10mW, Fixed 0.1% (k = 2); WR-22 waveguide power reference, frequency. 33GHz ~ 50GHz, power. 1mW ~ 10mW, uncertain 0.1% (k = 2); WR-15 waveguide power reference, frequency. 50GHz ~ 75GHz, power. 1mW ~ 10mW, uncertain 0.1% (k = 2). 3.3 delivery method Power reference using DC replacement technology, calorimetric technology for various forms of RF and microwave thermistor power (Hereinafter referred to as thermistor block) the effective efficiency of the assignment, to the lower level of measurement for the value of transmission.

4 measurement standards

4.1 Name 4.1.1 Type N Thermistor Block

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 2009-2016_English be delivered?

Answer: Upon your order, we will start to translate JJG 2009-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 2009-2016_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 2009-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 2009-2016?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 2009-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.